npm audit flagged both against the production dependency tree, and the
Frontend Security job fails on any fixable high-severity finding there
(FIXABLE HIGH: linkify-it).
linkify-it 5.0.1 -> 5.0.2 (GHSA-v245-v573-v5vm, high, CVSS 7.5) fixes a
quadratic-complexity DoS in the mailto: validator scan loop. It reaches us
only through prosemirror-markdown inside @tiptap/pm; the editor's own
autolinking uses linkifyjs, which is a different package and unaffected.
Nothing under frontend/src/ imports prosemirror-markdown or markdown-it and
neither appears in the production bundle, so the vulnerable code is tree-
shaken out and no running install was exposed.
dompurify 3.4.11 -> 3.4.12 (GHSA-c2j3-45gr-mqc4, low) fixes a
CUSTOM_ELEMENT_HANDLING bypass of afterSanitizeElements for allowed custom
elements. DOMPurify is shipped, but we never set CUSTOM_ELEMENT_HANDLING and
register no afterSanitizeElements hook, so the bypass has no precondition;
ProjectPageModal additionally passes a strict ALLOWED_TAGS/ALLOWED_ATTR
allowlist.
Both patched versions already satisfy the ranges their parents declare, so
this is a lockfile-only change - no overrides entry needed, package.json
untouched. npm audit reports zero vulnerabilities, npm run build is clean,
and all 2423 frontend tests pass.
Drop the off-white background on the A2L marketing render so it composites
cleanly on the dark theme (every other printer image in public/img/printers/
is RGBA with transparent corners; A2L shipped as opaque #F7F7F7). Resize to
320x320 to match the rest of the artwork.
Also wire A2L into getPrinterImage so the printer card actually shows the new
artwork -- without this the resolver fell through to default.png for both
the A2L display name and the N9 internal SSDP code.
- frontend/public/img/printers/a2l.png: new, 320x320 RGBA, transparent
- frontend/src/utils/printer.ts: A2L / N9 -> a2l.png, placed above the a1mini
branch
- frontend/src/__tests__/utils/printer.test.ts: 4 cases mirroring the X2D
shape -- display name, case-insensitive variants, N9 internal code,
regression guard against accidentally matching A2M / A1 / A1 Mini
The Bambu Lab X2D (launched April 2026, dual-nozzle, enclosed, hardened
steel rod gantry, AMS 2 Pro compatible) identifies itself as internal
model code N6 via SSDP/MQTT, and real serials begin with 20P9. None of
these identifiers existed in Bambuddy's registries, so the camera
service fell back to the chamber-image protocol on port 6000 (X2D
doesn't speak it), firmware-check logged "Unknown printer model: N6",
and the dual-nozzle K-profile paths — gated on the H2D serial prefix
"094" — would have treated X2D as single-nozzle.
Backend:
- Register N6 → X2D across every registry (PRINTER_MODEL_ID_MAP,
PRINTER_MODEL_MAP, STEEL_ROD_MODELS, ETHERNET_MODELS,
CHAMBER_TEMP_SUPPORTED_MODELS, firmware-check API keys + wiki path,
virtual-printer SSDP/product/serial tables, DB vp_model_fixes).
- supports_rtsp(): match the X2 display-name prefix and the N6 internal
code; camera now routes to RTSP on port 322.
- Dual-nozzle serial prefix check in bambu_mqtt.delete_kprofile and
kprofiles.set_kprofile broadened to ("094", "20P9") — X2D now takes
the H2D-style cali_idx in-place edit path.
- is_h2d model gate in bambu_mqtt.start_print extended with "X2D" so
timelapse / bed_leveling / flow_cali / vibration_cali / layer_inspect
are sent as integers and external-spool ams_id 254/255 routing is
preserved (H2D-style deputy-nozzle addressing).
X2D uses hardened steel rods like P2S — it is intentionally placed in
STEEL_ROD_MODELS, not CARBON_ROD_MODELS. A regression-guard test pins
the classification.
Frontend:
- mapModelCode in PrintersPage and SpoolBuddyAmsPage handle N6 and X2D.
- Enclosure-door badge and airduct-mode whitelists include X2D.
- MaintenancePage.getMaintenanceWikiUrl routes X2D to P2S wiki URLs for
steel-rod lubrication, belt tension, cold-pull, and PTFE tube
(exported to enable direct unit testing).
Tests:
- test_printer_models.py: TestX2DModel (10 assertions).
- test_bambu_mqtt.py: X2D in start_print ams_mapping and is_h2d gate;
TestDeleteKProfileDualNozzleDetection across H2D, X2D, P2S, X1C.
- MaintenancePageWikiUrls.test.tsx: 15 assertions covering X2D, P2S
regression, X1C/H2D/A1Mini regression, and model-name normalisation.
Docs:
- README: added X2 series to the supported printers table.
- CHANGELOG: new entry under 0.2.3b4 Fixed.
Credit to @krautech for the report and debug bundle, and to @legend813
for PR #989 which seeded most of the registry changes — rod-type
classification was corrected (steel, not carbon) and the dual-nozzle /
K-profile / is_h2d gaps were added on top.
Sends persistent notifications to the HA dashboard using the existing
HA connection from Settings. Zero config — just select "Home Assistant"
as provider type. Users can forward notifications to mobile via HA
automations.
home_flag bit 18 was incorrectly interpreted as "wired/ethernet
connection", causing the ethernet badge to always show — even on
printers without an ethernet port (e.g. A1, P1S). This hid the
WiFi signal indicator entirely.
Removed the wired_network field and ethernet badge UI. The WiFi
signal badge now shows correctly whenever the printer reports
signal strength.
Nozzle rack id 0 = extruder 0 = right nozzle, id 1 = extruder 1 = left.
The dual-nozzle hover card had them backwards, showing serial number and
max temp on the left column instead of the right. Serial and max temp
are now restricted to the right (removable) nozzle only. Single-nozzle
fallback (H2D, H2C) updated to use the primary nozzle (id 0).