The nozzle-diameter guard compared the sliced diameter against the
mounted hotends alone. On an H2C both hotends commonly read the same
size, so a job sliced for anything else was failed before upload with
"install the matching nozzle before printing" -- even with that nozzle
sitting in the tool-changer rack, which the printer fetches by itself
as part of starting a print. The reporter saw it as an asymmetry:
going to 0.4mm always worked, going to 0.2mm never did, and only
fetching the nozzle by hand on the printer's own screen let the print
run. It was never only about 0.2mm -- with a 0.6mm docked and 0.4mm
hotends, a 0.6mm slice was refused identically.
Placement is what made it fatal rather than merely wrong. The guard
runs near the top of _start_print and the rack picker near the bottom,
so the item was failed before the code that would have chosen the dock
ever ran.
Bambuddy had the rack contents the whole time. nozzle_info carries an
entry per nozzle -- ids 0/1 for the hotends, 16-21 for the docks --
each with its diameter, so the guard now tests the slice against both
sets. It keys off the ids rather than the printer model: only a rack
machine reports 16-21, which leaves no registry to keep in sync. An
empty dock is absent from the payload entirely, so an id appearing
there already means a nozzle is in it. stat is left uninterpreted; it
read 0 on every entry, occupied and empty alike.
A diameter in neither a hotend nor a dock still stops the print before
it uploads, and the message now names both sets so the machine's real
stock is visible.
The same telemetry showed a second fault, pointing the other way. A
hotend with nothing mounted is still reported, keeping the diameter of
the nozzle it last held -- measured at idle, where the rack-side hotend
read 0.4mm with max_temp 0 and serial "N/A" after parking its nozzle
back in the dock. That stale value counted as installed. Presence now
comes from the serial and the temperature rating, and emptiness has to
be stated rather than merely unstated: the serial must be the
firmware's explicit "N/A" and the rating absent. A firmware that
reports neither field normalises to exactly that, and reading it as
empty would switch the guard off on that machine.
Confirmed on an H2C with 0.4mm hotends and a 0.2mm in R6: the job
dispatches with nozzle_mapping [21], chosen by Bambuddy rather than
left to the firmware.
Every pipeline endpoint answered 403 for API keys whatever scopes the key
carried. PR A parked all three permissions on the admin denylist until the
run dispatch existed to decide about; it landed in PR C and the parking was
never revisited.
PIPELINES_READ now rides can_read_status. PIPELINES_RUN requires
can_queue AND can_manage_library together, so the allowlist gained tuple
values: a run slices into the library and then queues prints, and mapping
it to either flag alone would hand that flag the other one's authority.
The 403 names every flag the key is short of. PIPELINES_WRITE stays
admin-only -- a key can run the recipe, not rewrite it or clear the log.
Opening the run route also needed the cloud-owner fallback the direct
slice route makes: a pipeline can carry Bambu/Orca Cloud presets, and
resolving those reads a token off a user record that an API-keyed request
does not have. retry_failed forwards the new dependency explicitly,
since a direct call receives the Depends marker rather than None.
Bed levelling, flow calibration, and nozzle-offset calibration were on/off
only, so the sole way to run bed levelling was to force a full level before
every print. Bambu Studio has always offered a third "Auto" state that lets
the printer skip the calibration when it was done recently -- the state most
users actually want. Make these three options tri-state (off/on/auto),
defaulting to auto, and leave vibration/layer-inspect/timelapse as on/off
(Bambu Studio exposes no auto for those).
Wire encoding follows Bambu Studio's source exactly: each option sends a JSON
bool (true only for "on") plus a companion int -- off=0, on=1, auto=2. The
bool fields stay booleans (the #1478 H2S regression); only the companion int
widened from {0,1} to {0,1,2}. #1721's observation that stage 8/39 stays
queued when sending 2 is the auto contract (queued, skipped at runtime if
recent), not a broken "off".
- schemas: TriState = Literal[off/on/auto] with a BeforeValidator coercing
legacy bool / 0-1 / true-false so old clients and un-migrated rows validate
- model + migration: boolean columns -> String; SQLite via column affinity +
data backfill, PostgreSQL via ALTER COLUMN TYPE guarded on information_schema
(verified on both dialects); settings rows normalised true/false -> on/off
- MQTT: start_print takes the tri-state strings and emits the paired bool+int
- Virtual Printer: reconstructs the slicer's auto/on/off from the int companion
(auto_bed_leveling / extrude_cali_flag) in both capture paths
- frontend: CalibrationMode type; off/auto/on segmented controls in the print
dialog, queue bulk-edit, and Settings -> Workflow; calibrationMode_* strings
in all 11 locales
The Configure AMS Slot picker was hardwired to 0.4mm (nozzleDiameter
prop never passed from PrintersPage / SpoolBuddyAmsPage), so a 0.6
machine could only set 0.4 profiles on its trays. Resolve the real
installed nozzle per-AMS (ams_extruder_map on dual-nozzle) and pass it
in. Separately, nothing validated the sliced nozzle against the
installed one, so a mismatch reached the printer as a cryptic HMS
_8012 "Failed to get AMS mapping table". Add a fail-safe pre-dispatch
guard in _start_print that fails the item with an actionable message