mirror of
https://github.com/maziggy/bambuddy.git
synced 2026-10-01 03:31:25 +02:00
dev
9
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
9500c046c0 |
Ask which nozzle to feed when a Filament Track Switch is fitted
Load and Unload in the AMS slot menu did nothing on an H2C with the switch fitted. The ams_change_filament command carries an optional extruder_id and Bambuddy never sent it. That is correct on every printer without the switch, and is what BambuStudio does there too -- each AMS is wired to one hotend, so the firmware works the target out for itself and an explicit value would only be a guess at something it already knows. Fit the switch and every AMS is bound to one of its two inlets instead, either hotend is reachable from any slot, and a command naming neither leaves the firmware nothing to act on. It was discarded in silence. Load now asks which hotend to feed, on the same terms as Bambu Studio: no preselection, so a stray Enter cannot feed the wrong one, and the hotend already fed from that very slot greyed out. Printers without a switch send a byte-identical command and still load in one click. A switch fitted but not yet set up -- any AMS still unassigned to an inlet -- refuses the load up front rather than publishing one the firmware will drop, mirroring DevFilaSwitch::IsReady, which likewise demands a switcher position on every AMS. Unload was addressed at the same time. It was aimed with tray_now, a single value for the whole printer, so on any dual-nozzle machine with both hotends loaded it unloaded whichever that field happened to name regardless of which slot's menu was used. It now names the slot and resolves the holding hotend from device.extruder.info, previously read for temperatures only. That resolution is gated on the printer having reported two extruders: single-nozzle machines do send the block, but nobody has read a single-nozzle snow value off the wire, and staking every X1C, P1S and A1 unload on an unverified encoding buys nothing where tray_now is already unambiguous. Both new state fields ride the WebSocket and are in the broadcast key, and both are computed in the REST status route as well -- that response is what the page has before any push arrives, and leaving them at their defaults would have told a correctly set-up machine that its switch was not set up. Verified on H2C-1, AMS-A slot 3: loaded and unloaded from each hotend in turn, all four correct. Covered by 18 MQTT unit tests, 4 status-dict tests, 7 integration tests and 6 component tests. Two known stragglers, both deliberately left alone. Load on an AMS-HT slot has never worked -- an HT unit is addressed by its unit id rather than ams*4+slot, which these endpoints do not accept -- so unload there keeps the printer-wide form it always used instead of gaining a slot it cannot name. And a slot's K-profile still follows the AMS's plumbing rather than the nozzle just loaded, so loading to the far hotend leaves the other one's calibration bound; that is the same per-nozzle problem the filament and K-profile redesign is scoped to fix. |
||
|
|
7a42e0a7e5 |
Show which Filament Track Switch inlet each AMS feeds
With a switch fitted, an AMS is not wired to a nozzle any more. It is plumbed into one of the switch's two inlets and reaches both nozzles through it, so every unit reports its extruder as "not fixed" (0xE) and ams_extruder_map comes back empty on these machines. The printer card had nothing to fall back on but the AMS unit number, so AMS-A was badged R and AMS-B was badged L purely because their unit ids are 0 and 1, a third unit got no badge at all, and every one of those labels was wrong. The SpoolBuddy assign modal had the same fallback in a worse form, mapping anything that was not extruder 1 to R. The binding turned out to need no new telemetry. BambuStudio reads it out of bits 24-27 of the same AMS info string we already parse for the AMS type and the extruder id -- 0 is In-B, 1 is In-A -- and it is only meaningful when a switch is installed, because without one 0xE really does mean an uninitialised unit and those bits carry nothing. That gates the read, which in turn forced the switch block to be parsed before the AMS block: _handle_ams_data runs early in _process_message and _update_state only much later, so the binding was lost on every frame that carried both. _parse_fila_switch is split out and called first, and left in _update_state as well so that stays a complete absorb step. The badge keeps L and R rather than A and B, because the lettering is familiar and matches the physical layout. It is a different colour from the plain nozzle badge, and its tooltip names the inlet in full, since the letter is the inlet's position and not a claim about which nozzle that AMS feeds -- the switch can route either inlet to either outlet. An AMS still reporting a real extruder id keeps its ordinary badge, which BambuStudio also treats as authoritative over any switch binding, and a switch that has been fitted but not yet set up on the printer shows nothing rather than a guess. The print dialog's slot dropdown gets the same label. It replaces a left/right hint that never once rendered: ftsExtruderForSlot compared snow-encoded in[] values against global tray ids and could not match. Decoding it correctly would not have saved it -- the firmware reports which slot sits in each inlet and which nozzle each outlet feeds, but never which inlet is currently paired with which outlet, so no per-slot nozzle can be derived. That function is gone rather than fixed. The dialog also points out when every filament a print needs sits behind one inlet. Bambu's own guidance is that this is legal but slow: a change between two filaments on the same inlet retracts the outgoing spool all the way back to its AMS before the next can be fed up the shared tube, where a change across the two inlets only retracts as far as the switch. All on one inlet means every change in the job takes the slow path, and moving a single spool fixes it. So it advises, it does not block. Both views update live. Two things were stopping that. fila_switch and ams_switch_inlet were absent from printer_state_to_dict, and the frontend shallow-merges each WebSocket push over its cached status, so a field the push omits keeps whatever the last full fetch left behind. And the broadcast dedup key had no term for either, so "Join IN-B" on the printer screen moved nothing: the binding is not in the tray component of that key, and it is not in the AMS change-hash either, which covers tray fields only and must stay that way because it drives Spoolman sync. Assigning an AMS to an inlet remains printer-side. BambuStudio can read the binding and has no command to write it -- its switch class is parse and getters only, and the recommended-arrangement popup draws and publishes nothing -- so there is no wire format for us to copy. Adding the two fields to PrinterState broke four test modules whose SimpleNamespace stubs predate them. The stubs are fixed rather than the production reads made defensive: the real dataclass always carries both, and a getattr in the dedup key would silently stop tracking the field if it were ever renamed. |
||
|
|
9ee162d51a |
feat(printers): expose P2S/X2D accessory fans (left aux + exhaust)
The P2S/X2D have two fans bambuddy didn't fully handle. On the P2S both are add-on kits; on the X2D they ship from the factory. 1. Left auxiliary part cooling fan — not shown or controllable. It is reported ONLY as device.airduct part id 10 (raw id 160 >> 4; FAN_REMOTE_COOLING_1 in Bambu Studio's DevFan::ParseV3_0) and is never mirrored into a flat big_fanX_speed field, which is why it was invisible. This is the gap identified in #2576, where the single 'Auxiliary' fan (big_fan1 / M106 P2) only reaches the right-hand aux fan. 2. Chamber exhaust fan — shown on every P2S labelled 'Chamber Fan'. On P2S/X2D Bambu's firmware/UI (and Bambu Studio's FAN_CHAMBER_0_IDX) call it 'Exhaust', and it is a kit on the P2S rather than built in. Both are now detected from device.airduct.parts, which lists only the fans that physically exist, so each tile appears only when the hardware is present. - bambu_mqtt: parse airduct part 10 -> left_aux_fan_speed (None when absent) and part 3 presence -> exhaust_fan_present; set_fan_speed() accepts index 10 plus a set_left_aux_fan() helper - schema / status route / printer_manager broadcast / mqtt_relay expose both fields - POST /printers/{id}/fan-speed accepts fan=aux2 -> M106 P10, the command Bambu's official P2S machine profiles use - frontend: 'Left Auxiliary Fan' tile shown when reported; big_fan2 tile labelled 'Exhaust' and presence-gated on P2S/X2D, unchanged 'Chamber Fan' elsewhere - i18n: leftAuxiliary + exhaust for all 12 locales Verified fan -> field map on a live P2S (fw 01.02.00.00), stable across cooling and heating airduct modes: Part cooling -> cooling_fan_speed / airduct id 1 (built in) Aux -> big_fan1_speed / airduct id 2 (built in) Exhaust -> big_fan2_speed / airduct id 3 (kit) Left aux -> airduct id 10 only (kit; forced off in heating by mode config) Tests: airduct id-10 parsing (raw 160 -> id 10, not literal 160), id-3 presence, base-P2S absence, diff-push survival, clamping, malformed entries, M106 P10 emission, invalid-index rejection; fan-speed API aux2->10 mapping; frontend tile presence and labelling per model/kit. |
||
|
|
8fd1f884dc |
feat(mqtt): publish the plate-clear gate and add a notification for it (#2525)
When a print reaches a terminal state Bambuddy holds the queue until
someone confirms the build plate is clear. That gate was visible only in
the Web UI: the printer's own MQTT push reports nothing beyond RUNNING,
PAUSE, FAILED, FINISH and IDLE, so an external automation could not tell
"finished" from "finished and still waiting for a human".
The per-printer status topic now carries an awaiting_plate_clear field,
and every transition is additionally published on a new retained topic,
bambuddy/printers/{serial}/plate_clear. Retained, and published from the
flag itself rather than from printer telemetry: a subscriber learns the
state of every printer the moment it connects, and the state stays
correct after Auto Off powers a printer down - telemetry stops there,
which would otherwise leave the status topic frozen at false.
Publishing is edge-triggered. The queue clears the gate on every
dispatch whether or not it was up, and no subscriber should see a
"plate cleared" for a plate that was never dirty. Persistence and the
WebSocket broadcast stay unconditional; they are idempotent and predate
this.
A matching Plate Clear Required notification event was added, off by
default on every provider because it fires after every print at the
same moment as the print-complete alert. Only the rising edge notifies.
Acknowledging still goes through POST /printers/{id}/clear-plate.
Two tests in test_printer_manager_status_broadcast.py asserted
_schedule_async.call_count == 2 for the setter. The new emission makes
it three on a transition, so they now assert that the persist and
broadcast coroutines are actually scheduled - which is the contract
Translated in all locales; wiki updated. Covered by backend and
frontend tests.
|
||
|
|
b1cb26f6ee |
feat(ams-backup): add status badge + toggle, fix prefer-lowest (#1766)
Two tightly-coupled deliverables in one drop -- a new AMS Filament Backup status/control surface, and the #1766 fix that depends on it. Added -- AMS Filament Backup status + control - Parse bit 18 of top-level print.cfg into PrinterState.ams_filament_backup on every push_status. Verified against OrcaSlicer source (DeviceManager.cpp:4961) and a live H2D ON/OFF capture. Tri-state (None = A1 family / pre-cfg push) preserves today's behaviour. - Hold-timer guard (3 s) prevents stale frames from flickering the badge back to the printer's old cfg after a user-initiated toggle. - POST /printers/{id}/ams-backup toggle, set_ams_filament_backup() client method calling _set_print_option("auto_switch_filament", enabled). - GET /printers/{id}/inventory-remain endpoint exposes the same map the dispatcher uses (internal and Spoolman modes both work uniformly). - Small icon badge in the printer card's "Filaments" section header (placement reads as printer-wide because the cfg bit is printer-wide, not per-AMS). Click to toggle, success toast. - 5 i18n keys x 11 locales for the badge UI. Fixed -- #1766: prefer_lowest didn't pick lowest, ignored backup state - Backend gate in _compute_ams_mapping_for_printer: coerce prefer_lowest to False when status.ams_filament_backup is False; log the skip. - New effectivePreferLowest(setting, backup) helper applied at every frontend sort entry point: single-printer PrintModal, multi-printer hook per-printer, PrinterSelector InlineMappingEditor, FilamentMapping standalone editor (the last had NO preferLowest awareness at all before this change). - New preferLowestSortKey(f, inventoryByTrayId) mirrors backend's two-tier key exactly, including the banding tie-break (regular AMS < AMS-HT < external) so the client-side pre-compute matches the dispatch-time pick. An earlier draft used a flat `amsId * 4 + trayId` priority which gave external slots (ams_id = -1) a NEGATIVE priority -- caught in code review before commit. - Settings -> Filament -> "Prefer lowest remaining filament" gets an explanatory note about the printer-side AMS Backup dependency, with i18n key in all 11 locales. |
||
|
|
b444921021 |
test: drop racy printer_state_to_dict patch; assert structural shape
The patch on printer_state_to_dict raced against the broadcast coroutine under pytest-xdist's parallel workers. Mostly won locally, lost occasionally on CI — surfaced first as AttributeError on .kprofiles, then (after _fake_state was hardened) as a dict-content mismatch between the patched return value and the real 36-key dict. Fix: stop patching printer_state_to_dict; let it run for real against the complete _fake_state stub. Assertions now check the broadcast fired with the right printer_id and a dict containing awaiting_plate_clear, not the exact dict shape — that decouples the test from printer_state_to_dict's evolving body. |
||
|
|
c36bfa24d4 |
test: harden _fake_state against printer_state_to_dict mock-leakage
The two TestBroadcastStatusChange / TestEndToEndUnderRunningLoop tests patch printer_state_to_dict to return a fixed dict, but on parallel xdist runners (CI's pytest -n 30) the patch occasionally didn't catch the call and the real function ran against the 4-field SimpleNamespace fake — first attr access (.kprofiles) AttributeError'd, swallowed by the try/except in _broadcast_status_change, send_status never awaited, the assertion failed. Filled _fake_state with every attribute the real printer_state_to_dict reads (iterables empty, scalars None, stg_cur=0 for the int comparison in get_derived_status_name). Test now passes whether or not the patch lands. |
||
|
|
57af8a1c19 |
feat(projects): URL field + cover photo on project cards (#1155)
Two new project fields: a free-text URL rendered as a one-click
external-link button beside the project name on every card (opens in a
new tab, click is e.stopPropagation()-guarded so it doesn't enter the
project), and a cover photo that replaces the status-icon box with a
square thumbnail.
URL is plumbed through ProjectCreate/Update/Response/ListResponse,
including from-template + create-template flows so it inherits between
a project and its template. Cover photo is not inherited because the
file would be shared on disk between source and copy.
Schema validator rejects anything other than http:// or https://
prefixes -- <a href> rendering would otherwise execute javascript:
/ data: / file: URLs even with React's default escaping. PATCH uses
model_fields_set for the URL field so users can clear it by sending
{"url": null}.
Cover image storage: Project.cover_image_filename references a file
Cover image storage: Project.cover_image_filename references a file
inside the existing archives/projects/{id}/attachments/ dir, but it's
tracked separately from the attachments JSON list so swap/delete on
the cover doesn't perturb the user's other attachments. Three routes
(POST/GET/DELETE /projects/{id}/cover-image) accept only .jpg/.jpeg/
.png/.gif/.webp (no SVG -- SVG can carry script payloads), replace in
place (prior file deleted before the new one lands so repeat uploads
can't accumulate orphans), and self-heal when a DB reference points at
a vanished disk file by clearing the column and 404'ing.
GET cover-image is gated by RequireCameraStreamTokenIfAuthEnabled
(accepts ?token=... query string) -- not the bearer-token gate -- so
<img src> requests work in both auth-on and auth-off configurations.
The frontend wraps getProjectCoverImageUrl with withStreamToken(),
matching the existing pattern from getArchiveThumbnail.
Permissions: PROJECTS_UPDATE for upload/delete/PATCH, PROJECTS_READ
gate is implicit via the stream-token credential. Migration: 2
idempotent ALTER TABLE projects ADD COLUMN. Localised across all 8
UI languages.
|
||
|
|
096bdd92a8 |
fix(#1128): broadcast printer_status when awaiting_plate_clear flips
awaiting_plate_clear is a Bambuddy-side flag, not a printer-side one,
so toggling it does not produce an MQTT push from the printer. Commit
|