The archive card, the library file details and the slice dialog all read
the layer height from a 3MF's project_settings.config. That records the
project's settings and can still describe an earlier process or another
plate; the plate's own G-code - what the printer executes - was never
consulted for it, because the parser read the first 4KB, enough for the
layer count in the header block but not for the config block that carries
layer_height 14-25KB in. A print running at 0.08 on the H2C archived as
0.2 with the layer count from the same file correct beside it.
The plate G-code now wins wherever the two disagree, and the plate that
was printed is the one read - the header parse used to take the first
gcode entry in the zip regardless of which plate the archive was for.
Source 3MFs, which carry no G-code, keep the project value as before.
---
Stop carrying a file's layer height over the preset you picked
Bambuddy carries a designer's process deviations across a re-slice
(#2622) and pre-ticked every one that was not machine-coupled.
layer_height is one MakerWorld projects routinely carry, so picking
"0.08mm High Quality" for a file whose designer had moved layer height to
0.2 sliced at 0.2 while the dropdown still read 0.08 - the same 0.2 the
settings panel showed, tagged "from file".
Layer height and first layer height are now classified preset_defining
and treated like the machine-coupled keys: offered, never pre-selected.
The flag travels on DesignOverride so the modal and the backend agree,
and the panel's badge names the conflict and shows the preset's own value
next to the file's, so ticking one is a deliberate choice.
Three bugs on the same PLA-model + PVA-support flow, discovered in
sequence:
(A) substitute_unused_plate_filaments inspected only object geometry
(per-object extruder metadata + paint_color triangles) so a support-
only slot was silently treated as "unused" and the user's PVA profile
got overwritten with slot 1's PLA.
(B) _extract_filament_info stripped filament_is_support==1 entries,
hiding PVA from unsliced source archive cards even when the project
explicitly configured it.
(C) --load-settings is authoritative over the source's project_settings.
config, and Bambu's shipped process presets ship enable_support=0
(supports are a per-print decision, not per-quality). So even with
(A) fixed, the sliced output had supports disabled and the PVA slot
loaded but never consumed. Inverts BambuStudio GUI's semantics where
the project overrides the preset.
Fixes:
- New extract_support_filament_slots_from_3mf reads enable_support +
support_filament + support_interface_filament from project_settings.
config; substitute_unused_plate_filaments unions it into the geometry-
derived set.
- _extract_filament_info returns all configured filament types + colours.
- New _patch_process_support_settings overlays four fields (enable_
support, support_filament, support_interface_filament, support_type)
from the source 3MF onto the picked process preset JSON before
--load-settings sees it. Deliberately targeted to what fixes#1881
without widening to a full project-over-preset merge.
ThreeMFParser._parse_3dmodel left XML-escaped values raw, so a Title of
"PCB Vise & Solder Station" landed in the DB as the literal "&" and
React re-escaped it on render to "&". Apply the same
loop-until-stable html.unescape() the sibling ProjectPageParser already
uses, uniformly across all <metadata> values.
Same drop: rewrite the VP archive-name-source tooltip in all 11 locales.
BambuStudio 2.7.x (PrintJob.cpp:314-325) overwrites the user-typed
Send-dialog name with the slugified 3MF Title field whenever one is
present, so the previous "handy if you renamed the job in the send dialog"
copy was false. New text spells out the actual behavior; both Filename
and Metadata modes often produce the same string for that reason.
Two stacked causes under-reported multi-plate prints in the project
rollup and the archive card.
Root cause 1 - parser only read plate 1.
ThreeMFParser._parse_slice_info used root.find(".//plate") and pulled
prediction / weight from that one element. Any multi-plate file's
archive-level print_time_seconds / filament_used_grams reflected
plate 1 alone. The /plates endpoint already looped findall and was
correct, which is why the plate carousel showed the right numbers
while the archive card was wrong.
Fix: loop every <plate> and sum prediction + weight. Per-plate
concepts (plate_number, _plate_index, printable_objects) only set
when there's exactly one plate - for multi-plate exports the
archive represents all plates and a single index doesn't apply at
the file level. bed_type keeps the first plate's value as a
best-effort default. Malformed prediction / weight on individual
plates skip cleanly rather than poison the sum.
Root cause 2 - project rollup aggregated PrintArchive, not the
per-run log.
compute_project_stats and list_projects quick-stats summed
PrintArchive.print_time_seconds / filament_used_grams / cost /
energy_* WHERE project_id. A reprint reuses the source archive row
and writes a new PrintLogEntry, so 3 sequential runs collapsed to 1
archive - and that archive's numbers were already plate-1-only from
cause 1. The Archive Print Log path was already correct because it
drove off print_log_entries (archives.py:420 comment).
Fix: both compute_project_stats and the list_projects quick-stats
block inner-join print_log_entries -> print_archives WHERE
archives.project_id. total_archives becomes COUNT(PrintLogEntry.id),
failed_prints counts runs in failed/aborted/cancelled/stopped,
completed_items is SUM(PrintArchive.quantity) for runs where
status='completed', time/filament/cost/energy from PrintLogEntry.
Orphan log rows (archive_id IS NULL post archive deletion) are
excluded by the inner join.
Same-shape fixes carried forward (no follow-ups per project rule):
system.py system-info totals: total_print_time / total_filament
had the same bug shape - summed PrintArchive directly so reprints
collapsed to one row. Now sums PrintLogEntry.duration_seconds /
filament_used_grams. The semantic shift is also a correctness
improvement: the field now reflects time the printer actually spent
printing, not slicer-estimated time.
archives.py time-accuracy metric: estimate / actual per run where
estimate = PrintArchive.print_time_seconds. Post-parser-fix
multi-plate archives have file-level estimate but per-run actual =
one plate, so ratio = N x 100% for an N-plate file. The calc now
clamps each row to the [50%, 200%] plausibility band before
contributing to the printer-level average; single-plate accuracy
(the case the metric is designed for) stays fully included.
Backfill: users with AMS spool tracking - the reporter's case - have
per-run filament_used_grams from the tracked spool delta, so stats
become correct immediately. Users without tracking fall back to the
archive estimate and undercount until they reprint. Archive card
still reads PrintArchive.filament_used_grams directly so old
multi-plate archives keep plate-1-only numbers until reslice -
forward-only as the reporter accepted.
Re-slicing a 3MF authored for a single-nozzle printer (X1C, P1S, A1, P2S)
onto a dual-nozzle printer (H2D / H2D Pro) — or vice versa — previously
failed with "G-code in unprintable area of multi-extruder printers" (the
source's bed-coordinate layout lands in the H2D's per-nozzle dead zone)
or, on multi-color projects, a hard SIGSEGV inside the slicer's ZFiller
polygon-clipping. Earlier shipped a fail-fast 400 guard; this drop lifts
it and actually does the conversion by forwarding the sidecar's existing
--arrange flag when the source and target nozzle classes differ. BS
itself reconciles the embedded project_settings.config against the new
printer that way, the same way the GUI's "Switch Printer" operation
does. The guard becomes a kept-for-compat no-op.
Slice-all-plates added to the SliceModal: a checkbox for multi-plate
sources sends plate=0 to the backend, which forwards --slice 0 to the
BS CLI. Same-class slice-all produces one multi-plate output 3MF in a
single sidecar call. Cross-class slice-all loops per plate (BS's
--arrange is project-wide and would otherwise consolidate every plate's
objects onto one bed) and merges the per-plate outputs into one
multi-plate 3MF locally via the new merge_plate_3mfs helper. The toast
shows "Plate 2 of 5 — Generating G-code (47%)" through the loop.
Three side fixes surfaced during testing:
- substitute_unused_plate_filaments overwrites unused-slot filaments
with the slot-1 selection before slicing so BS's loaded-filament
temperature validator doesn't reject a PLA print whose unused slot 2
defaulted to ABS in the dropdown
- re-sliced archive thumbnail now prefers the source's per-plate
render (Metadata/plate_N.png) over the project-wide MakerWorld cover
art, because BS CLI with --arrange skips writing a fresh per-plate
preview
- re-sliced archive bed_type now lifts from the sliced output's
curr_bed_type onto the PrintArchive column the card actually reads
Schema: SliceRequest.plate range relaxed from ge=1 to ge=0 to admit
the "all plates" sentinel; SlicerApiService.slice_with_profiles /
slice_with_bundle take an `arrange` parameter.
Tests: 26 in test_slicer_3mf_convert (count / merge / substitute /
extract), 3 in test_slicer_api (arrange wire format), 9 in
test_library_slice_api (guard no-op, bed_type lift, thumbnail
fallback, new cross-class slice-all loop integration test), 2 in
test_archive_service (Auxiliaries fallback), 4 in SliceModal.test
(plate=0 toggle), 2 in SliceJobTrackerContext.test (multi-plate toast
prefix). 659 backend + 42 frontend green; backend ruff clean,
frontend build clean, i18n parity green at 4984 keys × 9 locales.
Five follow-up fixes to cross-printer re-slicing, all surfaced while
testing archive re-slices.
1. Re-sliced archive now records the printer it was sliced FOR.
slice_and_persist_as_archive copied sliced_for_model from the source
archive, so re-slicing X1C->H2D still showed "X1C sliced". Read it
from the freshly-sliced 3MF's parsed metadata instead, falling back
to the source only when absent.
2. Real slicer rejections are surfaced instead of silently masked.
_run_slicer_with_fallback retried with the 3MF's embedded settings on
any sidecar 5xx — including genuine content rejections (object off
the bed, incompatible filament temps), which "succeeded" only by
re-slicing for the source's original printer. A new
_slicer_rejection_message detects the slicer's own error string and
surfaces it as a 400; the embedded-settings fallback is kept only for
true CLI crashes.
3. A failed slice opens an error modal, not a 3s toast. The slicer's
reason is actionable and a toast hides it before it can be read. New
AlertModal (acknowledge-only); SliceJobTrackerContext shows it on a
failed job. New slice.failedTitle key in all 9 locales.
4. Sliced files no longer report "0 g" filament usage. The sidecar
doesn't always populate the X-Filament-Used-* headers;
ThreeMFParser._parse_gcode_header now also reads the slicer's own
"total filament weight/length" from the G-code header, and both
slice-persist paths fall back to it when the sidecar reports 0.
5. Nozzle-class re-slice guard. Re-slicing across the single-nozzle <->
dual-nozzle boundary (e.g. X1C -> H2D) fails BambuStudio's
multi-extruder validation; both slice routes now reject it up front
with a clear 400. The dual-nozzle model classification — previously
an inline tuple duplicated across start_print and the K-profile
routes — is centralized into DUAL_NOZZLE_MODELS / is_dual_nozzle_model
in printer_models.py, consumed by all three sites and the guard.
Full cross-nozzle-class re-slicing (dual-nozzle project_settings
reconciliation) remains separately tracked.
Tests: _slicer_rejection_message, _canonical_printer_model,
guard_nozzle_class_reslice, is_dual_nozzle_model, the G-code-header
filament parse, AlertModal, and end-to-end slice-API coverage including
an X1C-archive-to-H2D 400. Backend ruff + i18n parity clean; frontend
build clean.
- Remove 28 unused imports across 22 test files
- Prefix 4 unused local variables with _ in app code
(archives, bambu_mqtt, main) and remove 1 dead store
- Consolidate import/import-from in test_plate_detection.py
- Fix unreachable statement in test_archive_service.py
- Simplify redundant comparison in timelapse_processor.py
Resolves ~50 CodeQL py/unused-import, py/unused-local-variable,
py/import-and-import-from, py/unreachable-statement, and
py/redundant-comparison findings.
Replace xml.etree.ElementTree with defusedxml in test files to satisfy
Bandit B314 scanner. While test XML is trusted, using defusedxml
consistently across the codebase prevents CI failures.
Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
- Add "Recalculate Costs" button to Dashboard that updates all archive
costs using current filament prices (Issue #120)
- Track reprints and add cost to existing archive total on completion,
so statistics accurately reflect total filament expenditure
Closes#120
When reprinting a multi-plate 3MF file exported with "All sliced file",
the system now asks which plate to print and only maps filaments for
that specific plate.
Backend changes:
- Add GET /archives/{id}/plates endpoint to list available plates
with thumbnails, print times, and per-plate filament requirements
- Add GET /archives/{id}/plate-thumbnail/{index} for plate thumbnails
- Update GET /archives/{id}/filament-requirements to accept plate_id
query parameter for filtering filaments by plate
- Add plate_id field to ReprintRequest schema
- Update POST /archives/{id}/reprint to use plate_id from request body
instead of auto-detecting (maintains backward compatibility)
Frontend changes:
- Add getArchivePlates API method
- Update getArchiveFilamentRequirements to accept optional plateId
- Update reprintArchive to accept plate_id in options
- Add plate selection UI to ReprintModal when multi-plate 3MF detected
- Show plate thumbnails, names, and filament counts in selection grid
- Require plate selection before printing multi-plate files
- Filter filament requirements to show only selected plate's filaments
Tests:
- Add unit tests for multi-plate slice_info.config parsing
- Add unit tests for plate detection from gcode files
- Add integration tests for new plate endpoints
When exporting individual plates from a multi-plate 3MF in Bambu Studio,
all uploaded archives showed plate 1's name and thumbnail regardless of
which plate was actually exported.
Root cause: The 3MF parser used an incorrect XPath lookup (plate_idx
attribute) and didn't extract the plate index from slice_info.config
metadata.
Changes:
- Extract plate index from <metadata key="index" value="N"/> in
slice_info.config
- Remove incorrect plate[@plate_idx='N'] XPath lookup that doesn't
work for single-plate exports
- Set self.plate_number from extracted index so _extract_thumbnail()
uses the correct plate thumbnail (e.g., plate_5.png instead of
plate_1.png)
- Append " - Plate N" to print_name when plate index > 1 to
distinguish multi-plate exports
- Add 7 unit tests for plate index extraction and print_name
enhancement
Track individual parts/objects separately from print plates in projects.
Useful for multi-part builds like Voron where 25 plates produce 150 parts.
Backend:
- Add target_parts_count field to Project model
- Calculate parts_progress_percent and remaining_parts in stats
- Auto-detect quantity from 3MF printable objects when archiving
- Sum archive quantities for completed_count (parts)
- Use archive_count for plates progress
Frontend:
- Add "Target Parts" input in project create/edit modal
- Show separate progress bars for plates vs parts
- Stats footer displays both plates and parts count
- Header badge shows parts progress when target set
Scripts:
- Add update_archive_quantities.py to migrate existing archives
Tests:
- Add 5 integration tests for parts tracking
- Add 3 unit tests for 3MF object extraction
Closes#85
- New APIBrowser component with full OpenAPI schema integration
- Fetches and parses /openapi.json automatically
- Groups endpoints by API tags (printers, archives, settings, etc.)
- Expandable endpoint sections with color-coded method badges
- Path parameter, query parameter, and JSON body editors
- Auto-populates request body with schema examples
- Live API request execution with response display
- Response shows status code, timing, and formatted JSON
- Copy response button with clipboard fallback
- Search to filter endpoints across all categories
- Expand All / Collapse All buttons
- Link to Swagger UI (/docs)
- Two-column layout for API Keys tab
- Left: API key management + webhook documentation
- Right: API Browser with dedicated test key input
- Parameter validation
- Shows warning for missing required parameters
- Validates before sending requests to avoid 422 errors
- UX improvements
- "Use in API Browser" button on newly created keys
- Responsive layout (stacked on mobile, side-by-side on xl+)
Backend:
- pytest configuration with async support and coverage
- Unit tests for notification service (23 tests)
- Unit tests for smart plug manager (12 tests)
- Unit tests for archive service (16 tests)
- Integration tests for API endpoints
- Fix: notifications now send immediately (digest is summary only)
Frontend:
- Vitest configuration with jsdom and coverage
- MSW for API mocking
- Component tests for Toggle, Button, Card, ConfirmModal (77 tests)
- Test utilities with custom render wrapper
CI/CD:
- GitHub Actions workflow for automated testing
- Backend lint, unit tests, integration tests
- Frontend lint, type-check, unit tests, build