484 Commits
Author SHA1 Message Date
maziggy bf7fc67dc0 Choose what a spool label shows, preview it, and save it as PNG (#2981, #2980) 2026-09-30 11:08:05 +02:00
Kouki Ojima cb924e5c4a Match a Bambu roll to its own product line, not just its colour (issue #2907) (#2944) 2026-09-30 10:15:42 +02:00
maziggy 29e6d28205 Resolve LDAP groups on lldap and OpenLDAP (#3197)
lldap and OpenLDAP's memberof overlay omit memberOf from "*", so every
lldap login fell through to the default group. Request memberOf by name
when the schema defines it, and on non-AD directories also search the
directory root for groupOfNames/groupOfUniqueNames entries listing the
user, since groups often sit outside the user search base and the
overlay tracks only one group class.

Also: skip ldap3's anonymous schema read after StartTLS, which AD and
Samba AD reject, so StartTLS works there; reword a server's StartTLS
refusal with an LDAPS hint; stop the bundle sanitizer masking part of
an OID as an IP; skip the sync right after auto-provisioning so the
default-group warning logs once.
2026-09-30 09:46:54 +02:00
maziggy 2f7f17a891 Use the Spoolman spool's own initial_weight as its label weight (#3194)
Spoolman keeps a full spool's net weight on the spool (initial_weight)
and falls back to the filament's weight, but Bambuddy read only the
filament, so a 250 g spool of a 1000 g filament showed and synced as
1000 g. The list, weigh, AMS sync, SpoolBuddy scale, remain-% tracking,
fill bar and cost now share one lookup. Create writes initial_weight,
and a label-weight edit writes it instead of patching or duplicating the
filament. The spool form's cost per kg is converted at the spool's size
to and from Spoolman's per-spool price.
2026-09-30 09:12:45 +02:00
Thomansky 71d4b2f70d Material number as a first-class spool field (#2994) 2026-09-29 15:11:50 +02:00
Kouki Ojima cb5f04d287 Give the Low Filament notification something that fires it (issue #2913) (#2940) 2026-09-29 13:50:52 +02:00
maziggy 3497cf0d46 Hold an automatic slot unlink until the slot stays empty (issue #3186) 2026-09-29 09:37:04 +02:00
maziggy 033eff1254 Show Bambu's own HMS descriptions and the real alert level (issue #2728)
Document HMS levels, Bambu's descriptions and uncounted faults (issue #2728)
2026-09-28 13:57:02 +02:00
M2ABRAMSTANK 6c0292b09a fix(ams): show a parked drying command as not started instead of an active cycle (#3096) 2026-09-28 12:09:59 +02:00
Kouki Ojima ff07a82358 Keep the consumed-counter reset out of Spoolman's own numbers (issue #2906) (#2939) 2026-09-28 09:58:16 +02:00
maziggy 37502719b7 Fix external-spool usage charged to an AMS spool (#3166)
Print commands carry the external spool as -1 in the flat ams_mapping
(the firmware rejects 254/255 there) and the real target only in
ams_mapping2. We captured only the flat list, so external-spool prints
looked unmapped and the usage tracker's position-based fallback
charged them to the first loaded AMS tray.

- Resolve external spools from ams_mapping2 when capturing a
  project_file (dual-nozzle keeps 254/255, single-nozzle -> 254)
- Tracker: an explicit -1 no longer falls back to a positional tray;
  a mapping naming no tray for any used slot defers to tray_now
- Keep the #1822 H2S tray_now override working with resolved mappings
2026-09-27 09:34:19 +02:00
maziggy 1a84dfea5b feat(print-modal): show each printer slot's colour in the filament mapping (issue #3159)
The Print / Schedule dialog's filament mapping is where the colour a slice
asked for is compared against the colour actually loaded, and only the
left-hand side of that comparison had a swatch. The slot, and every slot in
its dropdown, was text -- and the text cannot be trusted: a slot's colour name
is resolved from the Color Catalog or, failing that, from hue, so a
third-party beige is announced as "Orange". A "Color mismatch" warning then
gives no way to tell a real mismatch from two names for the same hex without
opening the printer card in another tab, which on a farm swapping twenty or
thirty non-Bambu colours between machines is a check made many times a day.

Each slot now carries its colour and its hex, and the slot whose colour is
exactly the one the slice asked for is ticked. This works for a slot bound to
an inventory spool and for one configured through Configure Slot or on the
printer itself: the second kind has no inventory row behind it, and the
printer's own tray colour is then what draws. A bound spool contributes what a
tray record cannot -- SlotSpoolIdentity gains extra_colors and effect_type, so
a two-tone or glittery spool draws as itself rather than as its base colour.

The same treatment goes to the filament-override picker used for model-based
assignment. It is the same choice on the other dispatch path, and leaving it
text-only would have made one decision read two ways.

Both controls stop being <select>s to do it, because an <option> renders text
and nothing else. SlotPicker keeps what the select gave for free -- arrow,
Home/End, Enter and Escape keys, listbox semantics, and the border colouring
that encodes match, same-type-different-colour and not-loaded -- and is
portaled with position:fixed so it is not clipped by the dialog's own scroll
container, flipping above the row when there is no room below.
2026-09-25 11:38:13 +02:00
maziggy fc6b953816 fix(virtual-printer): give each install's CA a name of its own (issue #3014)
A slicer holding the CA of two Bambuddy installs could only connect to
one of them. Each CA worked on its own; together, one stopped, with the
generic "Connect ... failed! [SN:..., code=-1]" that an install whose
CA was never imported gives.

Every install signed as exactly CN=Virtual Printer CA. A slicer's trust
store is a flat list of certificates and OpenSSL resolves an issuer by
Subject DN: it takes the first authority whose name matches and fails
the chain when that one turns out not to have signed the certificate,
rather than trying the next match. Whichever CA landed second in the
file lost -- decided by nothing but the order they were appended in.
Reproduced with openssl verify against a bundle holding two CAs: the
first leaf verifies, the second fails with "certificate signature
failure".

- certificate.py: a newly generated CA takes a suffix from its own key
  identifier (CN=Virtual Printer CA D55808BE) and publishes that
  identifier, which the printer certificate points back at.
- Existing CAs are untouched, so nothing has to be re-imported. A
  printer certificate signed by one keeps exactly the shape it has
  today: the authority key identifier is added only when the CA has an
  identifier to name.
- tests: unique names per install, the identifier reaching the leaf,
  an existing CA being reused unchanged, and both chains verifying
  through openssl from a single trust store.

The collision goes away as soon as one of the two CAs is newer than
this change. Two installs that both predate it still collide until one
has its bbl_ca.crt/.key deleted and regenerated, which is a re-import
for that one -- documented in the wiki.

Reported by @Steven-Pierce.
2026-09-24 11:22:40 +02:00
maziggy 1b20d1a968 fix(notifications): send the ntfy priority the dialog was collecting (issue #3139)
The per-event Priority header from #990 never reached ntfy. The dialog
builds its rows from the provider's event toggles and stores the map
under those names -- on_print_complete, on_print_failed -- while every
sender is called with the bare event name, print_complete. The lookup
missed for all 18 events the dialog offers, so every notification went
out at the ntfy server's default with the configured priority sitting
untouched in the database.

Both ends looked healthy, which is why it shipped. The stored config
held exactly what was set, and the tests were green because they called
_send_ntfy directly with the prefixed name -- the one spelling the
running system never produces.

- notification_service.py: accept either spelling, bare first, so
  existing configs keep working and nothing needs migrating.
- schemas/notification.py: document both key forms, and which one the
  UI writes.
- tests: use the bare names, and add one that runs from a finished
  print through to the outgoing request. Without the fix it fails on a
  header dict holding only Title, which is the assertion that was
  missing.

The daily digest is unchanged: send_digest sends with no event_type at
all, and the dialog offers no priority for it -- it is one message for
several events.
2026-09-24 10:00:33 +02:00
maziggy 0eb083b32e fix(slicer): read the plate model once per part for the post-slice thumbnail (issue #3135)
The post-slice thumbnail loaded the sliced 3MF with trimesh, whose reader
mishandles the Bambu Studio / OrcaSlicer layout: for every component that
references a file in 3D/Objects/ it re-parses that file and appends all
of its meshes again. N copies of a part came back as N^2 copies of its
triangles, and each component carried every other part of the same file.
25 bins of 10k faces loaded as 6.4M faces; the render took 54 s and
8.4 GB on the event loop, and the server was OOM-killed.

Parse the 3MF directly (lxml, entities/DTD/network off, streamed and
freed element by element), walk objects, components and build items
(p:path on either) with their transforms, and keep each mesh once.
Decimate per unique mesh to its share of a face budget before placing
instances, flip winding on mirrored placements, and skip the thumbnail
above a face ceiling checked both on what decimation can reach and on
what it delivered.

Both slice routes run the render in a thread. The renderer uses
matplotlib's Figure/Agg API instead of pyplot, whose process-global
figure state let a threaded plate render and stl_thumbnail's
event-loop render lay out and close each other's figures.
2026-09-22 10:47:00 +02:00
Pascal Heidmann 036f0a688f Merge pull request #2845 from pascalheidmann/refactor/modular-import
(Refactor): modularize import ("Makerworld tab")
2026-09-20 12:12:56 +02:00
maziggy 0db028f9e6 fix(inventory): one structured 409 for a tag another spool holds (issue #3110)
The two tag-link routes answered the same conflict differently. The
built-in one said "Tag UID already linked to another active spool" and
named nobody -- while holding the conflicting spool row it had just
loaded -- and Spoolman mode named the spool inside a different English
sentence. Neither was machine-readable, so a client had to parse prose
to learn which spool to look at, and could only do it in one mode.

Both now raise one shared constructor: code tag_already_linked, the
holder's id, and which identifier collided. That is the detail shape
insufficient_filament and printer_connection_failed already use, so
ApiError parses it with no frontend change.

Two active spools can carry one tag -- no unique index on either
column, no conflict check on PATCH /spools/{id}, and /spools/bulk
copies one payload including the tag into every row it creates -- and
the lookup read that with scalar_one_or_none(), which raises on two
rows. The exception escaped into the auth middleware's fail-closed
handler, so the caller was told the authentication service was
unavailable. Both lookups are now ordered and take the first row, as
get_spool_by_tag earlier in the same file always has.

Naming the lowest id means the Spoolman scan reads every row where it
used to stop at its first match, so it now reads extra.tag defensively:
that field is edited outside Bambuddy, and a single null further down
the list would otherwise take the request down in place of the 409.

The kiosk reads the new code: a refused link showed a flat "Failed to
assign spool" and now names the spool holding the tag, reusing the
inventory.tagAlreadyLinked key that no code referenced.
2026-09-20 11:49:00 +02:00
maziggy 905bda4f3f fix(ams): read the firmware presence bit, not the tray state (issue #3084)
Swapping a Bambu spool for one the AMS cannot read left Assign Spool
publishing no ams_filament_setting at all. The printer kept showing "?"
on its screen and in the slicer, and only Configure, which publishes
unconditionally, put anything there.

Four places asked the tray's `state` field whether a spool was in the
slot. It cannot answer that. An AMS-HT reports its LOADED tray as 9
rather than 11, because it does not feed into a shared buffer the way a
4-slot AMS does -- the merge has skipped its own state heuristic for HT
units since #2594 for exactly this reason. And the field is partly our
own writing: apply_tray_exist_bits stamps state=9 on every slot whose
tray_exist_bits bit is 0, and when the bit comes back it refreshes only
the `exists` annotation beside it. Either way the slot sits at
exists=True, state=9 until something configures it.

That 9 also kept the deferred-configuration replay from firing -- its
own "has a spool appeared" test was the same heuristic -- which is the
deadlock #1322 removed from the assign path, still in place one step
further along. And it is what deleted the assignments in #3100: with the
replay never firing, the row kept the empty fingerprint it was stored
with, and the first tray report naming a filament was read as a swap.

All four now read tray_exist_bits first, which is the mask firmware
answers this question with and the one the printer card has drawn its
"?" from since #2527. The bit is allowed to overrule an "empty" state
and nothing else: a bit reading empty deliberately does not start
suppressing pushes that go out today, because the cost of computing a
bit position wrong is a slot that silently stops configuring, against a
saving of one message firmware would have dropped.

A blank tray report from a slot the bit calls occupied no longer unlinks
anything, off a print as well as during one, in both inventory modes --
Spoolman's parse_ams_tray calls a tray with no type empty, so a tag-less
spool assigned through the UI had its row deleted by the first idle push
after it went in. A filament the AMS cannot identify is not a filament
that was removed.
2026-09-20 11:13:20 +02:00
maziggy 4a85e033c0 fix(finance): show the currency the install is configured for (issue #3123)
The Finance page was the only surface in Bambuddy that read its currency
from a data row rather than the `currency` setting, and it fell back to EUR
where every other page falls back to USD. One variable drives every amount
on that page, so the personal balance, the cost-center budgets and the whole
transaction list were wrong together on any install not set to euros. It now
takes the configured currency from /settings/ui-flags, which is readable by
anyone who can see Finance -- /settings needs SETTINGS_READ, which a
cost_centers:read_own user does not have.

The backend was the other half. Of the four places that settle on a
currency, three wrote a hardcoded "EUR": the wallet the API mints on demand,
the wallet a print charge mints when none exists, and the balance returned
for a user with no wallet row at all. All four now go through one resolver,
which lives beside the rest of the balance logic.

The wallet's currency column is removed outright rather than merely ignored.
An install has one currency and nothing here converts between them, so a
per-wallet copy could only ever drift from the setting -- and a column
nothing reads is a trap for whoever finds it next. A startup migration drops
it on both SQLite and PostgreSQL, after the raw CREATE TABLE that would
otherwise re-add it on an install whose finance tables predate the ORM.
SQLite builds older than 3.35 have no DROP COLUMN and keep it, harmlessly,
since it has a default and no reader.

Saving settings now invalidates the ui-flags query too. Nothing did, so a
changed currency sat behind that query's staleTime before showing up. The
sponsor prompt's own EUR fallback is now USD, matching AppSettings.
2026-09-20 10:06:47 +02:00
maziggy 74173eab8d fix(vp): offer every host IP as a bind target, not one per adapter (issue #3121)
Each enabled virtual printer needs its own IP address, and the documented
way to get several is to add secondary addresses to the adapter already in
use. Linux reads those back through `ip -j addr show`, which reports every
address. Windows and macOS have no `ip` command and fell through to a psutil
enumeration that stopped at the first IPv4 of each adapter, so a host with
three addresses on one NIC offered exactly one bind target and the second
virtual printer could only fail with "Bind IP ... is already in use".

The psutil path now collects every address, marking the ones after an
adapter's first as aliases the way the iproute2 path does. Callers that want
interfaces rather than addresses -- the discovery scan and the support bundle
-- project the primaries back out, so their view is unchanged.

The ioctl fallback that a Linux host without iproute2 used to get is now
reached only when psutil itself is missing, which gains that host aliases
too. The interface-name exclusions stay Linux-only: they are Linux device
names, and a Windows adapter called "Local Area Connection" matches the "lo"
prefix.
2026-09-20 09:32:22 +02:00
maziggy 1ccaf74dd5 fix(install): sign the Python that macOS grants local network access to (issue #3114)
macOS attributes Local Network permission to a code signature and judges a
launchd-spawned process on its own, rather than letting it inherit the grant
of the Terminal that started it. Homebrew ships Python unsigned on Intel, so
there is no identity for the grant to attach to: every connection to a LAN
address is dropped with no error the application can log and no permission
prompt. The printer reads as unreachable and nothing says why, and the entry
in Privacy & Security cannot be made to work because it refers to an identity
that no longer resolves.

install.sh signs during a macOS install; update_macos.sh re-checks on every
update, because `brew upgrade python` installs a fresh unsigned binary under
a new versioned path.

Both sign only what is currently unsigned. That gate is load-bearing: on
arm64 the linker ad-hoc signs every binary and the identity is a hash of the
file, so re-signing would rotate it and revoke a working grant on each update.
A python.org build carries a real Developer ID and must not be downgraded for
the same reason.

The interpreter and the framework's Python.app are both signed. The first is
what sys._base_executable resolves to and what the reporter's TCC log names;
the second is what his fix actually targeted. Which one macOS attributes
could not be established from either, and signing both costs nothing.

-----

fix(diagnostics): name the macOS permission that silently blocks the printer (issue #3114)

The port checks reported all three ports unreachable while the subnet check
passed, and port_mqtt's fix text sent the reporter after firewalls and IP
addresses. On a macOS native install that pattern has a cause neither of
those covers: no Local Network grant, denied with no error and no prompt.

A new macos_local_network check, appended on macOS only so no permanently
dimmed row appears for anyone else. It passes when the control port answered,
which is proof the permission is in place and means the signature probe never
runs on a healthy diagnostic. Otherwise it probes the interpreter: an
unsigned one gets the repair that fixes it, a signed one gets System Settings
— the arm64 case, where the identity is a hash of the binary, so a Python
upgrade presents macOS with a new application and strands the old grant.

Always warn, never fail, and only once port_mqtt has already failed, so this
can never be why a green diagnostic turns red. A printer that is simply
switched off produces the same all-ports-dead pattern, which is why the
signature, not the pattern, is what earns the specific advice. An
undeterminable signature is reported as the generic case rather than as
unsigned: that advice rewrites a file in the user's Python installation and
must not be offered on a guess.
2026-09-19 16:03:52 +02:00
maziggy 3a5f802cdc fix(diagnostics): read the subnet the host is actually on (issue #3092)
The Network subnet check told the reporter that 192.168.98.170 and
192.168.96.9 were on different networks and to go configure routing
between them. They are four hundred addresses apart inside one
192.168.96.0/22 LAN.

An IPv4 address does not carry its prefix, and the check supplied /24
for both sides. That is the most common LAN and not the only one, and
the guess is wrong in both directions: it splits a /22 and it merges a
/25. Read the prefix off the interface that owns the address instead.

find_local_ipv4_network() enumerates every interface, including the ones
EXCLUDED_INTERFACE_PREFIXES hides. That list keeps docker0 and friends
out of the Virtual Printer's bind dropdown; here the caller is asking
about an address the kernel has already picked as a route source, and
answering "unknown" because it sits on a bridge would be a worse answer
than the truth. When nothing claims the address the check skips, which
is what it always did with no host IP at all -- it must not assert a
split it cannot see.

The same check chose which of Bambuddy's own addresses to compare by
probing a route toward 10.255.255.255, which on a multi-homed host is
not the interface the printer is on. It asks for the route toward the
printer now. On a two-NIC dev box that alone was warning about a printer
sitting on the second card's own subnet.

The probe takes IPv4 literals only. connect() on a name would resolve
it on the event loop, and _same_subnet rejects names anyway, so nothing
is lost. Resolving the prefix shells out to `ip -j addr show`, so it
moves off the loop too.

-----

fix(diagnostics): name the container engine instead of asking about Docker (issue #3092)

"Not running in Docker - not applicable", said to a Bambuddy inside a
Podman container. It reads as "you are on bare metal", and it sent the
reporter looking for his problem somewhere else.

Podman runs Bambuddy in exactly the two shapes Docker does, and the
shape is the thing that breaks printer discovery and the Virtual
Printer. detect_container_runtime() names the engine -- Docker, Podman,
Kubernetes, containerd, LXC, or a container it cannot place -- and the
check became Container network mode.

is_running_in_docker() is deliberately left alone rather than rewritten
on top of it. Three callers key real behaviour off that flag, and one of
them switches the Add Printer flow from SSDP to subnet scanning. SSDP
works for a host-networked Podman container, so answering True there
would take a working feature away to fix a sentence. Widening it is a
separate decision from naming the engine, so it is made separately.

Mode detection keeps the original signal first, which also makes the
Docker path incapable of regressing: a Docker host always has a docker0,
so a container that sees one shares its namespace, and the new rules can
only turn a warning into a pass. That signal says nothing about Podman,
which creates no such interface on a host running no bridge containers --
which is how host networking came to be reported as bridge. The general
form of the same idea answers for Podman: an interface whose iflink
equals its ifindex was created in this namespace, and a NAT-networked
container only ever receives one end of a veth pair. tun/tap is skipped,
because a container may run its own WireGuard and that tun is native to
a namespace it is not evidence of. The interface also has to be the one
the kernel just named -- sysfs is namespace-tagged but a bind-mounted
host /sys is not, and reading a colliding name's numbers would be
reading another namespace's answer.

What is still unreadable now says so and suggests host networking if
discovery is failing, rather than guessing bridge and telling a healthy
install to recreate itself. An LXC or LXD system container is named and
told the question does not apply: it is on the LAN like a small virtual
machine, so there is no network mode to recommend -- and its subnet
check still runs.

An engine we cannot name is a sentinel the frontend localizes, not a
word interpolated into thirteen other languages.

The support bundle carries the engine name beside the Docker flag, so
the next report of this shape is answerable from the bundle.
2026-09-19 12:19:19 +02:00
maziggy 2c7c97c130 fix(jog): send the nozzle-bed gap the API promises on every model (issue #1334)
POST /printers/{id}/bed-jog takes a signed nozzle-bed gap, documented since it
was written: positive asks for more room between the nozzle and the plate. On
an A1 it did the opposite. The reporter sent distance=5 for clearance and
watched the toolhead come down.

The sign had been flipped on A1 models since the original report on this issue,
where an A1 Mini owner clicked an arrow labelled "move the plate up" and watched
the nozzle dive. That is a labelling problem -- a bed-slinger's plate does not
move in Z at all, so closing the gap shows up as the toolhead descending -- and
it was solved in the transport layer, which turned a parameter documented as
model-independent into one that meant the opposite thing on part of the fleet.

Z is the nozzle-to-bed distance on every Bambu model, by definition of the
coordinate system rather than by convention: G1 Z+ opens the gap whether the bed
drops away from a fixed nozzle (X1/P1/H2, whose end G-code parks with
G1 Z{max_layer_z + 100}) or the nozzle rises off a fixed bed (A1/A2L). The
finish-photo plate restore already relies on exactly that and carries no model
branch. So distance goes onto the wire unchanged and one call means one physical
outcome everywhere: positive is the safe direction on every printer.

Which way an arrow points is a different question, about the machine in front of
the user rather than about G-code, so the printer card answers it and asks for
the gap it wants. The buttons move what you would expect them to move, exactly
as before; on a bed-slinger they now say toolhead rather than plate.

The A2L never had the old fix. It slings its bed the same way the A1 does, but
the inversion listed the A1 names and the A2L was not among them, so its up
arrow has been sending the toolhead at the plate for as long as the machine has
been supported. The new classifier also covers the alternate internal codes
A04 / A11 / A12, which LINEAR_RAIL_MODELS and SINGLE_NOZZLE_FLOW_MODELS both
carry and the old gate did not.

is_bed_slinger is gone from the backend rather than widened: with the route
model-independent it had no caller, and a kinematics helper sitting unused in
the service layer invites the next person to assume the backend handles
direction. It does not, deliberately.

Separately, the soft-endstop comments on both jog routes claimed the firmware
clamps a bare move at the travel limit. It does not, and #2579 measured that:
an H2D at its Z limit ran straight past a clean G91/G1 Z-1.00/G90, while its own
touchscreen refuses the identical move. What #2579 removed was M211 S0, which
disabled the limits globally and took the touchscreen's protection with them.
The jog popover has warned about this correctly the whole time; only the code
comments disagreed with it.
2026-09-19 10:38:54 +02:00
maziggy 0b830ac35c fix(ams): stop reading the printer's command acks as status (issue #3040)
Every project_file carried "cfg": "0" — the device-config bitmask, which
Bambu Studio has never sent and the firmware ignores. The printer echoes a
command's fields back in its ack, and the ack was ingested as telemetry, so
bit 18 read as "AMS Filament Backup off" 25 ms after every dispatch.

Families that repeat cfg in their periodic status (P2S, H2C, X2D) corrected
themselves a second later; the P1S, A1, A1 Mini and A2L send it only in a
full status dump, so the wrong value stuck and silently disabled the
prefer-lowest-remaining gate. The A1 family, which reports no cfg at all and
is meant to stay "unknown", was pinned to a definite "off".

Acks are no longer read as status, for the backup bit or the per-job
timelapse flag they also echo, and cfg is gone from the print command.
2026-09-16 09:52:24 +02:00
maziggy 309e64b8a2 fix(ams): resolve a slot's K profile by index when the printer does not file per hotend (issue #3044)
An X2D with two AMS 2 Pro, one per hotend, showed a K value on every slot
of the first and nothing on any slot of the second. Configure Slot was
worse than blank there: the picker offered no matching profile, the slot
read as though nothing were bound, and choosing one changed nothing the
user could see. Both symptoms are one rule.

A calibration index can mean two different profiles on a dual-nozzle
machine -- on the maintainer's H2C, index 16 is the left hotend's black
PLA at K=0.018 and 15 is the right's at K=0.020 -- so the index is
resolved against the slot's own hotend, and a miss shows nothing rather
than the other nozzle's number. That is right whenever the printer files
its calibrations per hotend. This one files them per filament: the second
AMS's slots point at the same entries as the first, every entry tagged
with one extruder, and requiring a match found nothing at all.

The hotend now has to appear in the table the printer actually sent
before it is used to narrow anything. Where it does not, the index stands
on its own, which is what BambuStudio does for this same card --
AMSItem.cpp resolves it through get_pa_k_n_value_by_cali_idx, matching
cali_idx and nothing else. Where it does, nothing changes: the H2C case
still blanks rather than borrowing, and the other hotend's profiles stay
reachable under Other K profiles. The relaxed path still refuses an
answer when the candidates disagree on a value.

The premise that the table is always numbered per nozzle had been written
into three comments and two layers of code; it is corrected where it
appears.

Alongside it, in the same picker: the K-profile options rendered the
hotend suffix twice in the matching group and three times under Other, so
every option on a dual-nozzle printer read "... . Left . Left".
2026-09-07 19:23:48 +02:00
maziggy 9a837d19a1 fix(slicer): strip zero-valued filament-index sentinels, and sanitise the preview slice too (issue #3030)
Bambu Studio writes 0 into wall_filament, sparse_infill_filament and
solid_infill_filament to mean "use whichever filament the object is set
to". Bambu Studio and OrcaSlicer 2.4 define these min 0 and accept it;
OrcaSlicer 2.3 and earlier used the 1-based scheme (min 1, default 1)
and reject it with "0 not in range [1.000000,...]". Sidecar images are
version-tagged, so an install can be pinned to one of those builds.

Same shape as the -1 inherit markers from #1201 with a different marker,
so the allowlist becomes a key-to-marker map rather than one global
constant. The buckets must not bleed: a -1 on a filament index is a real
value, and a 0 on a raft field is a setting the user chose.

The key is removed rather than rewritten, which is what makes it safe on
every build. The CLI then uses its own default: 0 where 0 was legal
(unchanged), 1 on the older builds, which is what "the active filament"
means under that scheme.

The preview slice never ran the sanitiser at all, so a file that sliced
fine could still fail its automatic plate preview and fall back to the
painted-face heuristic. It matters more there than in a real slice: the
preview runs on the file's own embedded settings, so there is no
--load-settings pass that could supply a replacement for a field the
range validator has already rejected. That also explains the reported
"same error on a later attempt of an unchanged file" without any second
copy of the keys -- the validator that emits it reads the merged global
config, which per-object model_settings.config overrides never reach.

The sanitiser moves to utils/threemf_tools so the service can use it
without importing a route module, and both preview callers pick it up
from one place. Drops _strip_3mf_embedded_settings and its constant,
which have had no callers since the strip-everything experiment was
reverted.
2026-09-07 14:37:49 +02:00
maziggy 10f0900fbc feat(ftp): log how every FTP session closes (issue #3009)
disconnect() and _abandon_connection() logged nothing, at any level. A
session closed cleanly and a socket genuinely abandoned therefore produced
identical output -- none -- and the only way to tell them apart was to read
the source.

That is how #3009 was filed. Its trace shows a print completion opening two
FTP connections, deleting one file, and then nothing until the printer was
powered off 21 minutes later, read as connections left open and offered as a
mechanism for the 0500-C010 SD-card error that #645 has been chasing since
April. The two connections are the post-print SD cleanup in main.py walking
its candidate filenames, each through delete_file_async, which closes in a
finally; running that against the mock FTPS server shows the server logging
"FTP session closed (disconnect)" for both the 250 and the 550, holding zero
sessions afterwards. Nothing in a support bundle could have shown that.

Both close paths now log one DEBUG line: the printer, whether QUIT was
acknowledged or the socket had to be dropped without it, why, and how long
the session was held. Every connect in a debug log now has a matching close.

The duration comes from a stamp taken when the control socket opens rather
than after login, so a session that dies during login is accounted for too;
where no socket was ever established the line says "held unknown" rather
than claiming a number. The four connect() failure paths pass their own
reason, so a close line stands on its own next to the warning above it.

Nine tests, seven of which fail against the unlogged version. The other two
assert silence -- a bare disconnect(), and a connect skipped by the handshake
cool-off -- where no socket was opened and a close line would pair with no
connect.
2026-09-07 10:54:55 +02:00
maziggy 9434875fa1 fix(ams): resolve a custom filament's own id from every preset source (issue #3003)
A custom filament profile reaches an AMS slot as itself through exactly one
field, tray_info_idx, and every source we can read that id from was reading it
from the wrong place or not reading it at all.

Bambu Cloud returns a preset's own filament_id either on the response envelope
or inside the preset JSON under `setting`, and only the envelope was read.
Presets of the second shape fell through to the base_id branch and reached the
slicer as the Bambu filament they inherit from. filament_type next door already
handled both spreads; filament_id now does too.

Orca Cloud was absent from the resolver entirely. A spool stores the bare
profile UUID, which matched no branch and fell through normalize_slicer_filament
-- a function that passes anything it does not recognise straight through -- so
a 36-character UUID went into the field. Orca profiles carry their own
filament_id in the slicer JSON that OrcaProfileDetail already exposes under
`setting`, so the lookup is the same one the Bambu branch does. It is
best-effort: no pairing, a dead token or a missing orca_cloud:auth permission
degrades to the fallback rather than failing the assignment, and it passes
clear_on_auth_failure=False because a background caller cannot tell a real
revocation from a lost refresh-rotation race.

configure_ams_slot sent the cloud setting_id as tray_info_idx when it found no
real filament id. That field is 8 characters on the printer -- exactly the width
of a local preset id, less than half a cloud one. Measured on the reporter's A1:
sent PFUS9ddc938fe3ab8f, the tray read back PFUS9DDC, acknowledged as a success.
The slot then resolved to nothing, so the slicer showed Generic anyway and the
calibration table, keyed by the same field, lost the slot. It now falls back to
the slot's existing filament id or the generic for the material, and the route's
guard was aligned with the resolver's so both refuse the same four shapes from
one shared definition.

This reverses the contract #1053 pinned. Six tests asserted that the PFUS
belonged in tray_info_idx; the A1 capture shows it never worked, so they were
rewritten with the measurement in their docstrings.

Verified against 874 AMS trays across twelve models in the support archive: 92
already carry a custom "P" + 7 hex filament id, which is what confirms the
mechanism works and this is a lookup failure rather than a platform limit. No
tray on any model carries a setting_id, so a profile with no filament_id of its
own still cannot be told apart from its base.
2026-09-07 10:15:06 +02:00
maziggy 0dfcff5925 Keep the RTSPS proxy's handler set off the server object (issue #3001)
asyncio's Server has a __dict__ and uvloop's, a Cython cdef class, does
not, so the attribute added in 1.2.5.4 raised AttributeError under uvloop.
Every RTSP camera failed before opening a socket, which is the
diagnostic's capture_exception at 0 ms.

Our own unit files all pin --loop asyncio for #1896 and were never
affected. The reports come from units we do not write: the Proxmox VE
Helper-Scripts LXC pins no loop, and installs predating that fix never
gained the flag because update.sh does not rewrite unit files. The loop
is not ours to assume, so fix the code rather than add another flag.

The set moves to a module-level WeakKeyDictionary, keyed weakly so an
abandoned proxy retires its own entry rather than leaking one and later
handing a new server a dead one's handlers.

Pinned on a real uvloop loop and, for hosts without uvloop, against a
__slots__ server; conftest builds its loop from the default policy, so
nothing in the suite had ever run the branch that broke.

Also routes the two external-camera teardowns through close_tls_proxy,
which #2968 introduced and left them out of.

-----

Say so at startup when running on uvloop (issue #3001)

An install on the wrong loop had no way to find out it was. #3001 was
loud enough to notice; the #1896 upload truncation it is also exposed to
is silent, and shows up as a print failing from a file that was corrupt
on arrival.

One WARNING in the lifespan naming the loop, the risk and the flag to
add. A warning and not a refusal: uvicorn has already chosen its loop by
the time any application code runs, and a server that answers requests
beats one that will not boot.

Asks the running loop what it is rather than whether uvloop imports --
uvicorn[standard] installs uvloop everywhere, so its presence says
nothing -- and matches on the module name so the question never imports
uvloop on a host without it.

-----

Repair a service file written before the --loop asyncio pin (issue #3001)

install.sh has pinned the loop since #1896, but nothing has ever
rewritten an existing service file, so every native install created
between 2025-11-28 (when uvicorn[standard] brought uvloop into the venv)
and 2026-07-05 still runs on uvloop no matter how often it is updated.

Both update scripts now add the flag themselves while the service is
stopped, so it takes effect on the same restart -- systemd via sed,
launchd via PlistBuddy, each backing the file up first and inserting
nothing but the flag.

Refuses to edit and explains instead when the shape is not a plain
single-line uvicorn unit: a wrapper script, a continued ExecStart,
several of them, a read-only file, or a service with drop-ins, since a
drop-in may be what defines ExecStart and editing the fragment would
change nothing while reporting success. A deliberate --loop uvloop is
left alone. Reads the effective ExecStart from systemd rather than the
file, so it is idempotent.
2026-08-30 08:01:42 +02:00
maziggy 49c948d01a Pin the TLS floor on the cleartext-probe test's context
CodeQL reports the context as allowing TLS 1.0 and 1.1, and it is right
about the mechanism: create_default_context() leaves minimum_version at
MINIMUM_SUPPORTED, which is the build's floor rather than a guarantee.
That is the reason every context in backend/app pins it, the reason
bambu_ftp.py carries a comment saying so, and the reason this same file
already pins it for the TLS-1.3 case further down. Line 127 was the one
that did not.

The floor cannot change what the test measures. The fixture answers with
a plain FTP banner and speaks no TLS, so the handshake still fails as
WRONG_VERSION_NUMBER, which is the assertion this test exists to make.
2026-08-29 15:29:59 +02:00
maziggy 0d21239e18 Send AMS tray colours as uppercase hex (issue #2987)
Assigning a spool to an AMS slot unassigned it again seconds later, and
the slot's colour changed at the same time. It presented as Bambu Studio
and Bambuddy fighting over the slot. The reporter's log shows Bambuddy
losing to itself.

P1S firmware 01.10.00.00 reads every lowercase hex letter in an AMS
tray_color as a zero, and hides it completely: the command response
echoes back the value that was sent and reports result "success", so
only the next AMS push says what was really stored. The spool-assign
path sent spool.rgba verbatim and that column stores lowercase. From the
bundle:

  sent 09ff00ff  ->  AMS reports 09000000
  sent ff5100ff  ->  AMS reports 00510000
  sent 090000FF  ->  AMS reports 090000FF

That is the visible colour change, and it is also what deleted the
assignment. The auto-unlink sweep asks whether the slot still matches
the spool assigned to it; the mangled colour no longer did, so the
assignment Bambuddy had made four seconds earlier was removed.
colors_similar('09000000', '09FF00FF') is False, which is the whole of
it.

Re-assigning could not recover, because the Configure Slot dialog seeds
its colour from whatever the printer currently reports. It wrote the
mangled colour back and cemented it, which is the loop the report
describes in its steps 4 and 5.

Colours are now uppercased where the command is assembled rather than in
each of the four routes that configure a slot. A caller that forgets is
exactly how this arrived. Nothing else changes: no padding, no invented
alpha, no six-to-eight widening, and tray_type and tray_sub_brands keep
their case, where it carries meaning -- "PLA Matte" is a product line,
"PLA MATTE" is not.

Two paths deliberately left alone. The developer-mode probe re-sends the
colour the printer itself just reported so that the probe is inert;
uppercasing there would turn it into a write. And the Virtual Printer
forwards the slicer's own command verbatim -- Studio could in principle
hit the same firmware bug, but nothing here evidences that it sends
lowercase, and rewriting a slicer payload inside a transparent proxy is
not a change to make on a hunch.

Two more defects from the same log.

A spool with a brand and no subtype was configured with the string
"None" in its name: the branded branch interpolated spool.subtype
without checking it while the unbranded branch guarded it, so
"Sunlu PLA Matte None" went on the wire and into Studio's display.

And the FTP log is readable again. A 426 whose bytes Bambuddy has
already verified against the printer is how Bambu FTPS normally ends a
transfer, not a fault, so it drops from WARNING to INFO. It fired 54
times in this one bundle, every one followed by a completed upload, and
it was burying the 26 TLS handshake failures in the same log that
actually cost the reporter two prints. A 426 whose bytes do not verify
is still an error and still fails the upload.

The handshake failures themselves are printer-side FTPS cool-off under
load and are not touched here.
2026-08-28 12:18:27 +02:00
maziggy 4d2c6debf7 Ask Spoolman which extra fields it has, once (issue #2983)
Bambuddy checked whether one of its four custom spool fields existed with
GET /field/spool/{name}. Spoolman has never served that. Its API declares
only POST and DELETE at that path -- confirmed against the live server's
own OpenAPI document -- so the probe answered 405 Method Not Allowed
every time and the check could not succeed on any version.

Every call therefore fell through to POST /field/spool/{name}, and that
endpoint is an upsert rather than a create. It answers 200 whether or not
the field is already there, so a field the user had renamed, retyped or
given a default to in Spoolman's own UI was reset to Bambuddy's version
of it, and an untrue "Created Spoolman extra field" was logged beside it.
The reporter's log carried 60 of those lines over three days -- once per
field per client init, which is every restart and every settings save.

Existence now comes from GET /field/spool, the listing endpoint, matched
on each row's `key`. Matching on `key` rather than the display `name` is
the part that fixes the overwrite: a renamed field is the same field, and
reading it as a missing one is what re-created it. A field that already
exists is now left completely alone.

The listing is read once per client and banked, so registering all four
fields costs one request instead of four, and a client that has already
looked makes none at all. Only a successful read is banked -- a client
that could not reach the listing asks again for the next field it has not
seen, so one transient failure does not leave it posting blind, and
overwriting, for the rest of its life.

An unreadable listing still falls back to attempting the POST. Registration
is best-effort by contract: it must not turn a write that might still
succeed into one that never happens, so an unexpected Spoolman build is no
worse off than before.

Measured against Spoolman 0.23.1: a field renamed to "Bambu RFID Tag"
survives a full registration pass that previously reset it, the pass makes
one GET and one POST for the single genuinely-missing field where it used
to make four POSTs, and a second pass on the same client makes no requests
at all.

The fake in test_spoolman_extra_field_registration_2903 modelled the
per-field path as a working probe, which is the assumption this bug was
built on; it now answers 405 as the real server does, and its assertions
follow the listing. 18 new tests cover the rest, 10 of which fail against
the old code.
2026-08-28 10:46:40 +02:00
maziggy 73e0787bfd Name an unnamed print stage "Preparing" on the card
New printers report stage numbers before Bambuddy learns their names,
and the H2C still has several. Those reached the printer card verbatim,
as "Unknown stage (72)" -- a number that means nothing to the person
reading it, on the one line that otherwise says what the printer is
doing.

Every stage that has turned out to be unnamed so far has been part of
the run-up to printing, so an unnamed one now reads as "Preparing".
That is the same literal stage 74 already carries rather than a second
spelling of the same idea, so a card cannot show two different words
for the same situation depending on which number the firmware picked.

Display only, and deliberately not pushed down into get_stage_name.
That function also feeds the stage-transition log line and the
once-per-session warning added to capture unnamed stages so they can be
named in a later release; there the number is the entire diagnostic
value, and replacing it with "Preparing" would hide the only thing that
reports these. Both paths are pinned by tests asserting they disagree
for an unnamed stage and agree for a named one, so a later tidy-up
cannot quietly collapse them.

The idle sentinels are untouched: 255 on A1/P1 and -1 on X1 mean "no
stage", not an unnamed one, and still resolve to nothing rather than
being swept up by the fallback.

Nothing keys logic off stg_cur_name -- it is display-only in the printer
card, the print dialog's printer selector and the stream overlay -- so
all three improve and none change behaviour. No i18n either way: the
whole stage table has always been English.
2026-08-28 09:51:14 +02:00
maziggy d5c7047765 Name an AMS slot after the spool assigned to it
The print dialog described every slot from the printer's own telemetry, and
a printer cannot describe a spool it did not sell: a tray record carries no
brand field, tray_sub_brands is left empty for anything that is not a Bambu
spool, and the colour arrives as a bare hex the client resolves against
Bambu's own colour catalogue. A Devil Design PLA Basic Orange assigned in
Bambuddy therefore read as "PLA (Sunflower Yellow)" -- Bambu sell a
Sunflower Yellow at the same FEC600 -- while the printer card, which reads
the assignment, named it correctly. Two views of one slot, disagreeing.

GET /printers/{id}/inventory-remain now carries each bound slot's brand,
material, subtype, colour name and hex alongside the pooling key it already
sent, and the dialog prefers that over telemetry. The fallback is per field,
not all or nothing, so a spool with no stored colour name still gets the
catalogue lookup it had before while its brand and subtype come from the
binding. Resolved server-side because the identity rule differs per
inventory mode -- brand is a column in internal mode and a nested vendor in
Spoolman's, where the subtype is the filament name with its material prefix
stripped and the colour name has a three-step read order Spoolman has no
field for. Spoolman's synthesised colour name, which falls back to the
subtype, is withheld rather than rendered as "PLA Basic (Basic)".

Matching is deliberately untouched and still runs on the printer's
telemetry. The auto-assignment, the colour-mismatch test and the mapping
that actually gets dispatched all read type, colour hex and tray_info_idx,
so renaming a slot cannot make the panel and the dispatcher draw different
conclusions from it. The payload is re-read on every open of the dialog: it
names the slots now, and a spool assigned moments earlier would otherwise
keep its old name for the rest of the thirty-second stale window. Done at
the two readers rather than by invalidating the key from each of the
eighteen places a binding or a spool can change, half of which are internal
paths and half Spoolman ones -- covering some would make freshness depend on
which mode you run.

Two hardening fixes fall out of putting a mapper on this path.
build_slot_materials runs before every queue start through
compute_deficit_for_queue_item, and _map_spoolman_spool walks a dozen nested
fields off the wire, any of which arriving as the wrong type raises
AttributeError rather than ValueError. Naming a slot must never cost a
dispatch, so that call fails soft to no name. The same inputs also reached
_material_identity_spoolman and _normalize_color_for_id, which have always
been on this path and would fail a queue start on a Spoolman record whose
filament is not a dict or whose color_hex is a number; both now read those
as "nothing to pool with". Behaviour for well-formed input is unchanged --
the guards only intercept types that previously raised -- so no pooling key
moves and AMS Filament Backup is untouched.
2026-08-27 16:04:41 +02:00
maziggy 9500c046c0 Ask which nozzle to feed when a Filament Track Switch is fitted
Load and Unload in the AMS slot menu did nothing on an H2C with the switch
fitted. The ams_change_filament command carries an optional extruder_id and
Bambuddy never sent it. That is correct on every printer without the switch,
and is what BambuStudio does there too -- each AMS is wired to one hotend, so
the firmware works the target out for itself and an explicit value would only
be a guess at something it already knows. Fit the switch and every AMS is
bound to one of its two inlets instead, either hotend is reachable from any
slot, and a command naming neither leaves the firmware nothing to act on. It
was discarded in silence.

Load now asks which hotend to feed, on the same terms as Bambu Studio: no
preselection, so a stray Enter cannot feed the wrong one, and the hotend
already fed from that very slot greyed out. Printers without a switch send a
byte-identical command and still load in one click. A switch fitted but not
yet set up -- any AMS still unassigned to an inlet -- refuses the load up
front rather than publishing one the firmware will drop, mirroring
DevFilaSwitch::IsReady, which likewise demands a switcher position on every
AMS.

Unload was addressed at the same time. It was aimed with tray_now, a single
value for the whole printer, so on any dual-nozzle machine with both hotends
loaded it unloaded whichever that field happened to name regardless of which
slot's menu was used. It now names the slot and resolves the holding hotend
from device.extruder.info, previously read for temperatures only. That
resolution is gated on the printer having reported two extruders:
single-nozzle machines do send the block, but nobody has read a single-nozzle
snow value off the wire, and staking every X1C, P1S and A1 unload on an
unverified encoding buys nothing where tray_now is already unambiguous.

Both new state fields ride the WebSocket and are in the broadcast key, and
both are computed in the REST status route as well -- that response is what
the page has before any push arrives, and leaving them at their defaults
would have told a correctly set-up machine that its switch was not set up.

Verified on H2C-1, AMS-A slot 3: loaded and unloaded from each hotend in
turn, all four correct. Covered by 18 MQTT unit tests, 4 status-dict tests,
7 integration tests and 6 component tests.

Two known stragglers, both deliberately left alone. Load on an AMS-HT slot
has never worked -- an HT unit is addressed by its unit id rather than
ams*4+slot, which these endpoints do not accept -- so unload there keeps the
printer-wide form it always used instead of gaining a slot it cannot name.
And a slot's K-profile still follows the AMS's plumbing rather than the
nozzle just loaded, so loading to the far hotend leaves the other one's
calibration bound; that is the same per-nozzle problem the filament and
K-profile redesign is scoped to fix.
2026-08-26 12:04:42 +02:00
Whitigol a68933cb2f Allow Avery label sheets to start at an unused position (#2879) (#2918) 2026-08-26 08:57:44 +02:00
maziggy 14f46510ba File the printer's calibration table under the nozzle it belongs to (issue #2854)
The K value on an AMS slot card went blank after a while and came back after a
backend restart. It is not the MQTT merge: that preserves a tray's k correctly.
H2-series trays have no k to preserve. Verified against the H2 wire capture in
logs/vp_wire -- every tray reports cali_idx and nothing else -- so the number on
the card is resolved from that index against the printer's calibration table in
state.kprofiles, and that table was a single global list.

An extrusion_cali_get response is the complete table for one nozzle diameter,
and the printer answers whoever asks; BambuStudio's queries arrive on the same
report topic we subscribe to. Every response was assigned straight to
state.kprofiles, so any one answer stood for the whole printer. The nightly
GitHub backup asks for 0.2, 0.4, 0.6 and 0.8 in turn and finishes on 0.8, which
holds nothing on a 0.4+0.6 machine: logs/bambuddy.log records exactly that at
17:15 on 2026-08-25, and the table was empty from then until something refilled
it. Responses are now bucketed by the diameter they describe, so an empty answer
for a size the printer does not have clears only that size. The three assign
paths that look an index up by nozzle_diameter get the same fix for free -- they
were quietly finding nothing whenever the last response was for another nozzle,
which is what spoolman_inventory has been logging as a stale kp.

Bucketing makes state.kprofiles a union, and cali_idx is numbered per nozzle, so
the index alone no longer identifies a profile. The REST serializer has keyed on
(extruder, cali_idx) since c5e005586; the WebSocket one still keyed on the index
alone, which meant the first render of a card could be right and every update
after it wrong. Both now share one resolver. It goes through the extruder the
slot feeds, and where that does not single out one profile -- a single-nozzle
printer that has been swapped, so both its tables sit under extruder 0 -- it
falls back to which diameters are actually fitted. Where neither settles it the
card shows nothing, because a blank space is a smaller error than confidently
printing the other nozzle's number. Deliberately no loosening to a bare cali_idx
lookup on a miss: that is the cross-nozzle bleed the extruder keying was added
to stop.

Nothing read the table on connect, which is the other half of the report. It
arrived by luck -- a visit to Profiles or Configure Slot, a backup, or the
printer answering someone else -- so a Bambuddy nobody had opened showed a card
with no K values at all, and "restart and they come back" was the printer
happening to broadcast rather than anything we did. It is now read once per
connection, on the same latch the stale-print reconcile uses. Only the fitted
diameters are asked for, one request on a single-nozzle printer and two on a
dual; probing the four sizes blind is what the backup does and what blanked the
table. The edge is gated on a nozzle diameter being known as well as on the
state being known, because the first push_status is what makes the state known
and does not always carry the nozzle fields -- latching there would spend the
connection's one attempt on a printer that could not yet say what was fitted.

Adopting an unsolicited table now logs at debug. It was the quietest way for the
card to change underneath us and there was no way to see it in a support bundle.

Three test files gained nozzles=[] on their PrinterState stubs. The field has
always been on the dataclass; the connect edge is simply the first thing on that
path to read it.
2026-08-25 17:52:02 +02:00
maziggy 08a58b1ef4 Keep both modes' slot assignments across an inventory mode switch (issue #2812)
Turning Spoolman mode on ran an unfiltered delete(SpoolAssignment) across every
printer. Turning it straight back off cleared the other table instead, so the
two directions were symmetric in code and one-way in effect, and the setting
auto-saves on a 500 ms debounce with no save button and no confirmation.
Opening the settings page to see what the option did was enough to destroy the
configuration: the reporter's log shows four toggles in 85 seconds, which is
someone looking and reverting, and the assignments never came back.

The deletion was not careless. Checks that read both assignment tables would
otherwise let a row in the mode you are not using answer for the mode you are,
which is how #1473 was fixed, and emptying the inactive table made that
impossible by construction. The cost was that the guarantee was bought with the
user's data. That decision belongs to the readers -- the mode is a property of
the install, not of the rows -- so spoolman_owns_assignments now answers it and
nothing is deleted on a toggle. Each mode keeps its own assignments and
switching is reversible. Existing installs need no migration: their inactive
table is already empty, because it was being emptied.

Six sites had to be told which mode they meant, and only two of them are the
reads you would guess at, the missing-assignment notification and the queue cost
estimate. The per-slot K-profile lookup consults the built-in table first and,
on a hit with no matching profile, deliberately stops rather than falling
through to Spoolman, so a leftover row would have shadowed the Spoolman binding
for that slot -- the symptom #1556 reported from the other direction.
configure_ams_slot *writes* a K-profile against whichever table answers first,
so the same leftover would have filed a calibration against a spool the printer
is not drawing on and never written the local one, leaving a calibration that
appeared to succeed and then did not apply.

The auto-unlink pass in on_ams_change is the one that would have made this
change worthless. It drops any assignment whose tray no longer matches the
fingerprint it recorded, and it ends in db.delete. Ungated, it would have
removed the preserved rows one slot at a time as the AMS contents changed under
the other mode -- the same loss, arriving slowly enough not to be connected to
the toggle that caused it.

The sixth is the built-in remaining-weight fallback inside the Spoolman AMS
sync, and it is deliberately left inert rather than woken up. It could never
fire while the table it reads was being emptied, it is keyed by slot rather than
by spool, and create_spool writes remaining_weight unconditionally where the
update path does not -- so preserving the rows would have seeded a stale figure
into a brand new Spoolman spool the first time a tray reported an unusable
remain%. The query stays, gated off, so the intent survives for whoever
revisits the cross-mode fallback.

Separately, a print that could not debit a spool said nothing about it, and that
is what turned a mis-click into lost filament. The reporter's print was already
running when they toggled. At completion it resolved its 3MF, read its
per-filament grams, resolved its tray, and then skipped the debit because the
assignment row no longer existed -- logged at INFO, invisible under the default
log level, while the completion notification fired as usual. 65.49 g was never
deducted and they only noticed because a spool's remaining weight looked wrong.
_resolve_spool_id_for_tray has no tag or fingerprint fallback, so there was
nothing else to catch it.

The skip is now a warning naming the grams, and a completed print that failed to
charge a tray it drew from raises the missing-spool-assignment notification. The
print-start check cannot cover this and was right to stay quiet: the assignments
existed when it ran. The two are different statements -- the first says the
weight may not be tracked, the second says it was not -- so a print warned at
start will notify twice, which is the right trade. Collected across the print
rather than fired per slot, and given the caller's session, because this runs
inside on_print_complete's transaction and opening a second one to read the
printer's name would deadlock against it on SQLite. This is independent of the
toggle and catches any other cause of an assignment disappearing mid-print.
2026-08-25 17:17:26 +02:00
maziggy 39835437a3 Price a print from the spool that fed it, not the default rate (issue #2591)
Spoolman holds per-spool pricing, and #261 gave that as the reason for
integrating with it. Nothing ever read it. A print's cost is set once, at
archive time, from the built-in Filament catalogue matched on the primary type
and falling back to a global default rate -- and in Spoolman mode nothing
revisited that figure afterwards. The per-spool recompute that would have fixed
it, in usage_tracker.on_print_complete, runs only over rows the built-in
inventory writes, and Spoolman mode hands the usage tracker spoolman_owns_usage
at print start so it writes none. The reporter's catalogue was empty, which is
the ordinary state of one in Spoolman mode, so every print came out at the
default no matter what the linked spool cost.

Multi-material was wrong twice over there: the primary type's rate applied to
the whole print's weight, so a slot of expensive PA was billed at the price of
the PLA beside it.

Each slot is now priced from the spool it was actually charged to, at the
moment of the charge, and the per-slot costs are summed -- which is what fixes
the multi-material case, rather than a separate change. All three charge paths
feed it: per-slot, tray-split, and the remain%-delta fallback. The rate is the
spool's own price when set, else the filament's, over filament.weight. That is
net grams excluding the core, and the same field the remain-delta path already
divides by to turn a percentage into weight, so a spool that can be charged by
percentage can always be priced. The price comes out of the get_spool call the
colour and material rewrites already pay for, so the tagged path costs no extra
round trip.

Grams no spool could price are covered at the global default in one subtraction
against the archive's own total. A spool with no price, a tray with no Spoolman
row, and filament the sliced file never attributed are the same case from here,
and without the top-up a print with one priced slot out of four would report a
quarter of its cost -- #1344 in the other inventory mode. Only the first run
writes the archive, matching the built-in writer (#1378); reprint actuals live
in PrintLogEntry. If no slot could be priced at all, whatever archive.py
recorded is left alone, so an install with prices in neither place stays where
it was.

Applied even when the slot-to-tray mapping was a positional guess, unlike the
colour and material rewrites beside it. Those overwrite what the slicer
recorded, which is why a guess must not touch them. The cost has no such
original -- archive.py's figure is itself derived from a default rate -- and the
grams have already been deducted from these spools, so the archive should say
what that deduction was worth.

Both cost recalculations would have undone it on the next run. /rescan and
/recalculate-costs rebuild an archive's cost from SpoolUsageHistory and fall
back to the catalogue or the default when there are no rows, which in Spoolman
mode is always, so the fallback was not a recalculation but a downgrade. The
spool-to-slot resolution a price is derived from exists only while a print is
completing and cannot be rebuilt from the archive row, so both now leave a cost
alone rather than replacing it with a worse one, and the bulk endpoint reports
how many it kept. An archive with no cost yet is still priced, and with
Spoolman off both behave exactly as before.

The rate parser refuses more than it looks like it needs to, because everything
it refuses was reachable. A non-dict filament raised through a call that sits
after a successful use_spool, which would have abandoned the remaining slots of
a multi-material print with the charges already made. NaN compares False
against every bound, including the applier's own total <= 0, so a NaN price
would have been written to the archive with nothing downstream able to clear
it; two finite operands can produce it by overflow, so the quotient is checked
as well as the inputs. A bool is an int in Python, and float(True) is 1.0 -- a
weight of 1 g prices a spool per-gram at its whole cost. And a spool-level price
of 0 now falls through to the catalogue rather than reading as free: Spoolman
leaves the override null when unset, but importers write 0 often enough that
treating it literally would price a whole print at the default with a good
catalogue price one level down.
2026-08-25 16:45:50 +02:00
maziggy 935d4b5bbf Charge the tray the printer said it used, not the first one loaded (issue #2953)
A sliced file numbers its filaments 1..4; which AMS tray each came from is
decided when the job is sent. #2768 gave the Spoolman writer two ways to
recover that decision when the print did not come through Bambuddy: the
printer's own mapping field, and a colour match of the 3MF's slots against the
loaded trays. An A1 satisfies neither. It publishes no mapping field, and it
drops the MQTT connection when we subscribe to its request topic, so the
slicer's instruction never arrives either. That leaves the colour match, and it
compares hex strings exactly.

The reporter sliced with a generic black profile against a tray they had set to
charged slot 1 to whatever sat in the first tray -- 2.17 g onto a grey PLA+
spool, while the print was fed from tray 3. Their bundle carries the printer's
own answer: "Tray change during print: tray=3 at layer=0", recorded 90 seconds
in, and read further down the same completion pass by _print_used_tray_keys to
decide which slots the print had touched. The same pass then charged tray 0 on
a guess, and logged "AMS0-T3: remain% did not fall over the print" about the
tray that had actually done the work.

_single_slot_tray_from_state adds the third rung. For a print with exactly one
slot carrying usage, the one slot came from the one tray, so the printer's tray
reporting answers the question directly: the mid-print tray-change log, then
the tray loaded at print start, then the current one, then the last real tray
seen. That is the ladder usage_tracker.on_print_complete has consulted since it
started resolving mappings at completion -- Spoolman users were the only ones
not getting it, which is why an install running the built-in inventory has
never shown this. On this printer only the first and last rungs can fire:
tray_now_at_start is 255 because print start runs before the filament is
loaded, and the A1 parks tray_now back at 255 the moment a print ends.

Gated on exactly one slot with usage, like the internal writer: a multi-colour
print moves tray_now on every change, so one reading cannot then be attributed
to one slot. It also declines when the log holds more than one switch, because
an AMS-backup runout is split per segment (#1793) and a single-tray mapping
would land the whole print on one spool.

That gate needed the guess warning to exclude the split path too. The split
never reads slot_to_tray at all -- it charges each segment to the tray the
printer announced switching to, which is the same evidence this fallback is
built on -- so a declined mapping there is not a guess, and calling it one
suppressed the archive rewrite for exactly the prints whose attribution is best
supported. Nothing covered that combination; a test does now.

Where nothing names a tray the positional default still stands, because it is
right for an AMS loaded in slicer order. It now says so at warning level so a
support bundle carries the reason, and it no longer restamps the archive's
filament colour and material from a spool it picked by position. That restamp
is what made the fault read as data loss: the grams can be put back, whereas
overwriting what the slicer recorded leaves nothing to compare against, and the
reporter's archive had already been rewritten from #000000 to the wrong spool's
grey. A slot that consumed nothing also stops claiming a tray in the handled
set -- it was never charged, so the remain-delta path should stay free to cover
it rather than be suppressed by an estimate of zero.

The request-topic probe is the same failure reached from the other side. A
printer that refuses kills the TCP connection instead of returning a SUBACK
failure, so the only signal is "we subscribed, then got disconnected", and that
was believed the first time it happened. Every other reason a connection drops
inside the same window looks identical -- a network blip, the printer
rebooting, the container stopped mid-probe -- and the verdict was cached per
serial with no re-probe anywhere, so on a printer that supports the topic one
unlucky drop cost mapping capture for the rest of the process and every slicer
print after it was charged by tray position. It now takes two consecutive
drops, and a disconnect we asked for is not counted. A printer that genuinely
refuses answers the same way every time and pays one extra reconnect; one
already known to refuse still skips the subscription outright rather than
reopening a reconnect loop.
2026-08-25 16:22:43 +02:00
Kouki Ojima 73912d4f05 Let a clear spool stay clear on the way to Spoolman (issue #2912) (#2924) 2026-08-25 13:45:57 +02:00
MagicMelody84 54af3146a3 [Feature]: Bind Home Assistant sensors to storage locations (dryboxes/bins) (#2827) 2026-08-25 12:17:23 +02:00
maziggy 5dd7bd213f Read a print's destination from the report topic, not just the request one (issue #1820)
current_project_url was assigned in exactly one place, _handle_request_message,
and _on_message calls that only for the request topic. A print started from the
printer's own screen publishes nothing there, so the field stayed None for the
one case the storage verdict exists for: the file is already in the printer's
model library under /userdata/model/history/, which port 990 does not serve.

The verdict then fell through to the sdcard flag, and @ojimpo's H2S reports that
flag true -- its "card" is the internal eMMC -- so every such print ran the full
sweep before giving up. He measured one: 16 filename-and-directory attempts over
22 FTPS connections, 18 of them refused, 6.4 seconds, then a fallback archive
holding a name and nothing else.

The printer does announce where the file lives, as an unsolicited project_file
*response* on the report topic about two seconds before gcode_state reaches
PREPARE. _process_message now reads the url off it, gated on result SUCCESS and
a non-empty value so a refused dispatch cannot name a file that was never
written. Reading it there rather than only at the request topic also covers an
install neither of us had in view: some brokers refuse the request-topic
subscription, and on those no print of any kind had ever populated the field.

The new branch captures state and nothing else. The "External project_file
payload" diagnostic stays with the request-topic handler: our own dispatch is
echoed on both topics, the request-topic echo lands first and clears
_own_project_file_key, so reusing the diagnostic here would have logged every
Bambuddy-started print as somebody else's. A test pins that.

What the print names is now what gets tried -- the five directories a copy could
be in, rather than the ~110 connections that cannot succeed. The probe is still
worth running: an H2S keeps recently used jobs under /cache and archives them in
full while they last, which is why the reporter's two prints on the same day
behaved differently. Slicer-sent prints are unchanged.

The banner no longer describes a step that never happened. With no reason
recorded, a blank archive fell back to the original wording -- "Store sent files
on external storage" is off in your slicer -- which on that printer is on, and
which the internal-storage wording from #2780 already explains would not help on
an H2. The archive that most needed that explanation was the only one that could
not be given it.

So file:///userdata/ now earns its own reason, internal_history, separate from
the brtc://emmc dispatch case. A dispatch chose internal storage and can be
aimed elsewhere; a print of a file that was already there had no dispatch at
all, and telling that operator to pick External in Send names a dialog they
never opened. The banner and the connection diagnostic both read the verdict's
reason rather than a fixed one, so the two surfaces cannot give the same printer
different advice. Thirteen locales, and a wiki section the banner links to.

-----

Read the K-profile selection when the mutation runs, not when it is captured

Configure Slot sends cali_idx from selectedKProfile, and the mutation read it
through its own closure. React Query hands a mutation its options from an
effect, so a click landing between a commit and that effect flushing runs the
previous render's mutationFn -- one that captured the selection as it was before
the K-profile query resolved. The payload then carries cali_idx -1 and the
printer binds the default 0.020 instead of the calibrated K, while the dialog
shows the right profile selected throughout.

It surfaced as an intermittent failure of the per-nozzle K-profile test, about
one full-suite run in six. Reproducing it with staggered query resolution showed
the divergence directly: the select element held the correct profile immediately
before and after the click, and the payload still carried -1. That test's slot is
the most exposed case in the file -- a right-hotend slot carrying the left
hotend's index, where the "keep showing the active profile" safety net cannot
repair an empty recompute.

The selection now goes through a ref written during render, so the mutation
resolves it at execute time. An effect would have inherited the same flush
ordering this exists to escape. The K value and the profile's ids travel in the
same payload and had the same exposure, so they move with it.

Measured over a staggered-resolution grid: 2 failures in 15 runs before, 0 in 12
after. api.getSlicerPrinterModels was also missing from the test file's mock, so
that query ran with no query function and rejected in all 37 tests -- mocked now,
though on its own it changed nothing, which is how the ref was confirmed as the
fix rather than assumed.
2026-08-25 11:19:46 +02:00
maziggy ed84f0f74c Anchor a plug-energy test to local midnight, not the wall clock (issue #2938)
test_nothing_derivable_before_the_first_midnight failed for 31 minutes of
every day and passed for the other 23.5 hours -- the shape that reads as
ordinary flakiness and gets re-run rather than fixed. @ojimpo hit it running
the full suite at 22:10 UTC, stashed his branch to confirm it reproduced on
clean dev, and measured the window minute by minute instead of guessing.

The test asserts that nothing can be derived when the only snapshot was
taken after this local midnight, and it placed that snapshot at a raw
wall-clock offset -- now minus thirty minutes. Its comment, "taken this
morning, after midnight", is the premise, and it is only true away from
the boundary. For the first half hour of each local day, now minus thirty
minutes lands before local midnight, where it is a perfectly good baseline:
_counter_at finds it and today comes back 1.5 rather than None.

The window is local 00:00 to 00:30, which is 22:00 to 22:30 UTC under CEST
and 23:00 to 23:30 under CET -- it moves with DST, since the module pins
Europe/Berlin in an autouse fixture and an outer TZ makes no difference.

Nothing is wrong with the production code. A snapshot from before local
midnight genuinely is a valid baseline for today, and derive_today_yesterday
is right to treat it as one. Only the test's premise breaks at the boundary.

The snapshot is now anchored to local_day_start(now) plus thirty minutes,
which is the idiom the other nine snapshot writes in this file already use
and the reason none of them can drift. Replayed across 5760 minutes covering
four days, including both DST switch days: the old expression fails 31
minutes per day, the new one fails none.
2026-08-24 13:29:28 +02:00
Kouki Ojima f95c81e6cd Take an RFID spool's core weight from the row that names it (issue #2909) (#2923) 2026-08-24 11:51:22 +02:00
maziggy 6988a30eae Carry a fault's description in the status response (issue #2926)
The HMS catalogue has been in the backend all along and the status
response never carried it, so every consumer that wanted to tell a user
why a print halted resolved the same 853 codes from its own duplicate of
the same sentences -- this repo's Python table, the frontend modal's, and
at least one third-party client whose catalogue exists purely because the
server would not say. Each ages separately, and a relay watching a
printer could only manage "your printer needs attention" while the server
already knew it was "Filament ran out. Please load new filament."

hms_errors[] entries now carry a description, defaulting to null so a
client that has never seen the field is unaffected.

It is resolved where the fault is parsed rather than at the boundary that
prompted the request, because there are three serializers of a fault, not
one: the status response, the WebSocket broadcast, and the completion
payload the queue's failure reason is built from. Adding it to only the
first would have handed half the feature to a relay watching the stream,
which is the likelier consumer of the three. The queue's failure reason
now quotes the resolved sentence instead of looking the code up a fourth
time, and the notification path reads it rather than re-deriving. That
they cannot report different text for one fault is the point, and a test
asserts they agree.

describe_fault is the single mapping from either code shape onto the
table. An 8-char print_error is the catalogue's MMMM_EEEE key with the
separator removed -- the parser derives full_code and that key from the
same 32-bit value -- so it resolves exactly. A 16-char hms[] identifier
is tried whole and then collapsed to its first and last groups.

That collapse is lossy, and keeping it was the decision worth making
carefully. #2728 counts 65 documented faults falling onto 0300_0001
alone, so a hit can attribute a neighbour's sentence to this fault, and
refusing it looks like the stricter reading. It is not: the notification
path, the queue's failure-reason helper and the frontend modal have all
resolved hms[] faults this way for as long as they have existed, and it
resolves real ones -- a 0500_4038 nozzle mismatch arrives in that shape.
Declining to collapse would have stopped describing faults that are
described today, silently suppressed the notifications they raise, and
left this field null while the UI showed text for the same fault.
Narrowing it belongs with #2728, where both key spaces can move together.

So the lookup is exactly what it was, verified rather than asserted:
a test walks every catalogue code in both fault shapes across all three
alert levels and checks the result against the derivation this replaces.
A future change to the lookup cannot quietly stop notifications firing.

The catalogue ships one language, so the field is English and
unlocalized, which the schema and the API reference both say next to it.
The camwall feed is deliberately left alone -- it is code-only because
its token travels in a URL on a screen, and a readable sentence discloses
more than the camera picture already does. The frontend keeps resolving
its own text: switching it would change what filterKnownHMSErrors counts
across eight call sites, which is #1840 and #2728's argument to have.

HMSError.message goes with this -- a text field that was never set or
read anywhere, and an invitation to populate the wrong one now that a
live description sits beside it.

-----

Record a failure code the user can actually look up

The queue's failure reason formats a fault's module and error into
MMMM_EEEE, and that one derivation never masked the error to 16 bits. A
fault arriving from the printer's hms[] array carries its alert level in
the code's high half, so the label came out as 0500_24038 -- five digits
in a group that has four. It is not a code anyone can find on Bambu's HMS
index, and because it matches no catalogue key the sentence explaining
the failure was dropped along with it, leaving the bare number alone.

The nozzle-size mismatch behind #1111 is exactly such a fault. Reported
one way it read "[0500_4038] The nozzle diameter in sliced file is not
consistent with the current nozzle setting"; reported the other, the same
physical fault read "[0500_24038]" and nothing else.

There is already a helper that gets this right, used by the archive's own
failure-reason lookup, so this calls it instead of keeping a fourth copy
of the derivation. It also takes the raw integer code the MQTT payload
carries, which the local version only handled as a string.
2026-08-24 09:47:39 +02:00
maziggy b38022ec5c Draw a spool the way the AMS described it, and correct the tare it was added with
Two faults in the same auto-add path, both found while tracing why an H2C
    slot named a wood roll as plain PLA.

    A spool's swatch is composed from effect_type and extra_colors, and the
    RFID auto-add set neither. It reads the colour catalogue to name the
    colour and took the name alone, even though the row it had in hand also
    carries those two columns -- the spool form's own colour picker hands both
    to a spool a user adds by hand, so the same roll rendered one way when you
    typed it in and another when the printer identified it for you.

    Both columns now travel with the name. That alone changes nothing on a
    stock install, because the shipped catalogue carries an effect on none of
    its 600-odd rows, so the subtype is read where the catalogue has none: it
    is already derived from what the printer reports, and the two vocabularies
    line up -- Wood, Silk, Sparkle, Marble, Glow, Galaxy, Metal, Rainbow,
    Translucent, Matte, and the Gradient, Dual Color and Tri Color that the
    M*/T* colour codes upgrade a subtype to. "Silk+" reads as Silk, since the
    plus is on the product name rather than the finish. A subtype that names
    no effect -- Basic, Tough, CF -- leaves the column empty rather than
    inventing an overlay, and a value already set is never overwritten, so the
    column stays what it is documented to be: a rendering hint the user can
    override without touching Bambu's categorical label.

    ------

    Correct the spool tare an RFID roll was added with (#2909)

    The lookup that gave an auto-added spool its core_weight asked for the
    first catalogue row whose name starts "Bambu Lab" and took whatever came
    back. There are three, and which is first is the database's business:
    SQLite returns insertion order in practice, Postgres promises nothing once
    a table has seen an update. The same roll was therefore recorded with the
    216 g High Temp tare on one install and correctly with the 250 g Low Temp
    one on another. @ojimpo's forward fix picks the row by name; this repairs
    the rows already written, which the forward fix cannot reach -- 22 of 26
    RFID-added spools on the instance this was traced on.

    The tare is not cosmetic. A spool weighed on SpoolBuddy has its remaining
    filament worked out as the scale reading minus the tare, so a 34 g low
    tare credits the roll with 34 g that is not there and writes a used weight
    34 g short. That error is a constant -- every later print adds to the used
    weight on top of it -- so adding the difference back is exact however much
    has been printed since. It is applied only to spools that have been on the
    scale; one that never was has a used weight derived from the AMS remaining
    percentage, which the tare never entered into.

    Rows are identified by the signature of the broken lookup: added by RFID,
    carrying the weight of one of the other Bambu catalogue rows, with the
    weights read out of the catalogue rather than hardcoded so an install
    whose rows have been re-measured is repaired to its own numbers. Keying on
    whether a catalogue row had been recorded would not have worked -- the
    weight picker auto-selects the only row matching the weight and writes its
    id on the next save, so that column says only whether the form was ever
    opened. The one case that cannot be told apart is stated rather than
    hidden: someone who moved an RFID roll onto a genuine High Temp spool and
    set 216 g by hand is normalised with the rest. Runs exactly once, so a
    tare set afterwards is kept.
2026-08-23 14:25:45 +02:00
maziggy 7b181b84f0 Let a filled or foamed filament keep its own name (issue #2902)
The reduction that gave an AMS slot a material type read PLA-AERO,
PLA-GF, ASA-GF and PPS-GF as their base material, so a slot loaded with
foaming or glass-filled filament went out saying plain PLA or ASA. That
is worse than the bug it replaced. "PLA-AERO" matched nothing before,
which was useless but honest; "PLA" matches every PLA plate in the
queue, so the dispatcher would have sent one to filament that will not
print it -- and the contract the first fix claimed, that it could only
ever repair a slot, no longer held. @doncaruana caught PLA Aero on the
issue.

All four are values Bambuddy itself offers: filament_fields.json is the
material list the Profiles editor puts in a dropdown, and the reduction
table was assembled from the cloud filament names and the frontend
preset parser without ever being checked against it. It is checked now,
so the next type added to one and not the other fails a test rather than
a print. ASA-AERO joins them from the cloud catalogue (GFB02).

The table hyphenates because the slicers do, while a spool says "PLA
Aero" and every Bambu preset name says "Bambu PLA Aero". Adjacent words
are joined and taken when the join is a type exactly -- exactly, because
letting the prefix and suffix rules reach across a space would make
"Support for PLA" a type by its tail.

Also from @doncaruana, and the better half of his point: a preset is
chosen from a list the slicer defines, so it already knows its own type
and nothing has to be read out of a product name. The resolver now hands
that answer back and both assign routes prefer it. It cannot be the only
source -- material is required on a spool and slicer_filament is not, and
the spool this issue was reported for had no preset at all -- so the
reduction stays as the fallback for spools without one.

Two things had to move with it. The auto-unlink guard compared the
slot's reported type against the reduced material, so a spool whose
preset outranked its material column would have been unlinked from the
slot it had just been assigned to; it now accepts any type the assign
path could have written. And two lookups keyed by material took the
catch-all for a type they had no row for, which sent an ASA-GF spool out
at 200/240 -- too cold to extrude -- and preheated its chamber to
nothing. Both fall back to the base material last, so PLA-CF, PETG-CF
and PA-CF keep the rows they are listed with, and ASA-CF and ABS-GF pick
up ranges they had been missing all along.

What counts as a material name is decided by the base for the same
reason: saying yes throws the value away and rescues the slot from the
generic-material fallback, so the answer has to be no when that fallback
has nothing to offer. ABS-GF reduces to a generic ABS the printer can
resolve; PPS-CF reduces to nothing and is left as it stands. Adding a
type to the table therefore cannot quietly change that answer, which is
how these five slipped through in the first place.

------

Hand the bundled chamber-preheat table back the way it is read

Every lookup of the per-filament chamber map happens after the keys are
upper-cased, and the parser documents exactly that: keys uppercased,
DEFAULT always present so the resolution loop can index it
unconditionally. The three fallback paths returned the bundled constant
as declared, with the lowercase "default" row the Settings editor writes
and displays, so an install that had never opened the setting got a dict
the loop could not read its fallback out of and used a hardcoded 0 for
any filament without a row of its own.

It reported the right number only because that bundled default is 0.
Raising it would have changed nothing for everyone who had not
customised the map, with the map in Settings still showing the value
that was not being used.

The test that should have caught this asserted the fallback under either
spelling, and its docstring contradicted itself between title and
comment. It pins the contract now, over all four ways the parser can
fall back.
2026-08-23 10:36:50 +02:00
Maksim Sadontsev ed85677913 Light the generated thumbnails so one model differs from another (#2816) (#2861) 2026-08-22 14:16:56 +02:00
Sean K 55cc64c87d Add printer video downloads and range selection (#2853) 2026-08-22 13:22:56 +02:00