Pull a Bambu ABS Orange out of A1, put a PLA Matte Dark Blue in, and the
slot card still read "Bambu ABS" against the new colour until the page
was reloaded.
Three things stood between the swap and a correct card.
The RFID auto-assign rewrites the slot's slot_preset_mappings row and
then broadcast an event that refreshed everything except the query that
reads it. Only the manual assign path invalidated that one.
Those queries then sat behind the 3s cascade debounce, which exists for
print completion, where one event fans out across half the app. A swap
touches one slot and the user is standing at the printer looking at the
card; worse, the timer restarts on every further event, so a busy moment
could defer it indefinitely. Slot changes now invalidate immediately.
And the card trusted the stored preset over live telemetry outright.
That priority is why a hand-picked preset name stays on a slot, but it
also let a cached row outrank what the printer was reporting. The row is
now skipped when it names a different official Bambu filament than the
tray does, so the card is right from the status push alone. User and
local presets carry ids that genuinely cannot be compared and are left
exactly as they were.
Spoolman mode was the worse half of the same bug: its AMS sync writes
the same row but announced nothing at all, so there was no event to
refresh on. It now reports each slot it changed or cleared.