9 Commits
Author SHA1 Message Date
maziggy 8e9821dd2a fix(mqtt): never wait for a wedged paho network thread (issue #3068)
The reporter's A1 had been offline 38 hours and still answered on 8883, so
the connection watchdog did exactly what it exists for: rebuild the session
with a fresh client, since anything left in the old one's QoS 1 queue would
otherwise replay onto the next print (#1136). The rebuild ended in paho's
loop_stop(), which sets a terminate flag and then joins the network thread
with no timeout.

That thread only reads the flag between iterations of loop_forever, so it
cannot read it while parked inside reconnect() -> _ssl_wrap_socket() ->
do_handshake(). paho gives that handshake the keepalive as its socket
timeout -- 30s here -- and a socket timeout is per operation, renewed by
every byte the peer sends. A printer that answers TCP and then trickles
holds the join open for as long as it likes.

The join ran on the asyncio thread. Bambuddy stopped answering anything --
UI, API, /health -- while the process stayed up, which is why a
restart: unless-stopped container never restarted.

Retiring a client no longer waits for it. The replacement is built at once
and the old one is shut down on a thread of its own that nobody joins. Its
callbacks are detached first, inline: blocking until the network thread was
gone is what used to guarantee a client we had let go of could no longer
touch our state, and with the teardown detached a zombie that finishes its
handshake would otherwise auto-reconnect and report itself connected behind
its replacement's back. disconnect() still goes out, still promptly, because
that is what stops paho's auto-reconnect and the replay with it.

The reported watchdog is one of six callers. The queue's dispatch recovery
and check_staleness -- reached from an ordinary status poll -- share
_hard_reset_client; editing, deleting and hand-disconnecting a printer share
disconnect(); the relay and smart-plug services had the same join on their
shutdown path, where a wedged broker stopped the process from exiting at
all. #1445 was this join too, from the add-printer probe, and its off-loop
teardown stays as it is.

disconnect() stays quiet on the way out, as it always effectively did.
paho's callback used to land during the join, but it suppresses itself for a
clean disconnect of a printer that reported in the last ten seconds, so a
healthy printer disconnected by hand never announced itself offline.
Announcing it now would tell the user their printer had gone offline a
minute after they disconnected it on purpose (#1752).

A retirement that takes more than five seconds logs which printer it was.
The whole point is that the next one of these should not have to be
diagnosed from a thread dump.
2026-09-18 17:13:26 +02:00
Gabe 9ee162d51a feat(printers): expose P2S/X2D accessory fans (left aux + exhaust)
The P2S/X2D have two fans bambuddy didn't fully handle. On the P2S both are
add-on kits; on the X2D they ship from the factory.

1. Left auxiliary part cooling fan — not shown or controllable. It is reported
   ONLY as device.airduct part id 10 (raw id 160 >> 4; FAN_REMOTE_COOLING_1 in
   Bambu Studio's DevFan::ParseV3_0) and is never mirrored into a flat
   big_fanX_speed field, which is why it was invisible. This is the gap
   identified in #2576, where the single 'Auxiliary' fan (big_fan1 / M106 P2)
   only reaches the right-hand aux fan.

2. Chamber exhaust fan — shown on every P2S labelled 'Chamber Fan'. On P2S/X2D
   Bambu's firmware/UI (and Bambu Studio's FAN_CHAMBER_0_IDX) call it 'Exhaust',
   and it is a kit on the P2S rather than built in.

Both are now detected from device.airduct.parts, which lists only the fans that
physically exist, so each tile appears only when the hardware is present.

- bambu_mqtt: parse airduct part 10 -> left_aux_fan_speed (None when absent) and
  part 3 presence -> exhaust_fan_present; set_fan_speed() accepts index 10 plus a
  set_left_aux_fan() helper
- schema / status route / printer_manager broadcast / mqtt_relay expose both fields
- POST /printers/{id}/fan-speed accepts fan=aux2 -> M106 P10, the command Bambu's
  official P2S machine profiles use
- frontend: 'Left Auxiliary Fan' tile shown when reported; big_fan2 tile labelled
  'Exhaust' and presence-gated on P2S/X2D, unchanged 'Chamber Fan' elsewhere
- i18n: leftAuxiliary + exhaust for all 12 locales

Verified fan -> field map on a live P2S (fw 01.02.00.00), stable across cooling
and heating airduct modes:
  Part cooling -> cooling_fan_speed / airduct id 1  (built in)
  Aux          -> big_fan1_speed    / airduct id 2  (built in)
  Exhaust      -> big_fan2_speed    / airduct id 3  (kit)
  Left aux     -> airduct id 10 only (kit; forced off in heating by mode config)

Tests: airduct id-10 parsing (raw 160 -> id 10, not literal 160), id-3 presence,
base-P2S absence, diff-push survival, clamping, malformed entries, M106 P10
emission, invalid-index rejection; fan-speed API aux2->10 mapping; frontend tile
presence and labelling per model/kit.
2026-07-28 11:16:22 -05:00
maziggy 8fd1f884dc feat(mqtt): publish the plate-clear gate and add a notification for it (#2525)
When a print reaches a terminal state Bambuddy holds the queue until
someone confirms the build plate is clear. That gate was visible only in
the Web UI: the printer's own MQTT push reports nothing beyond RUNNING,
PAUSE, FAILED, FINISH and IDLE, so an external automation could not tell
"finished" from "finished and still waiting for a human".

The per-printer status topic now carries an awaiting_plate_clear field,
and every transition is additionally published on a new retained topic,
bambuddy/printers/{serial}/plate_clear. Retained, and published from the
flag itself rather than from printer telemetry: a subscriber learns the
state of every printer the moment it connects, and the state stays
correct after Auto Off powers a printer down - telemetry stops there,
which would otherwise leave the status topic frozen at false.

Publishing is edge-triggered. The queue clears the gate on every
dispatch whether or not it was up, and no subscriber should see a
"plate cleared" for a plate that was never dirty. Persistence and the
WebSocket broadcast stay unconditional; they are idempotent and predate
this.

A matching Plate Clear Required notification event was added, off by
default on every provider because it fires after every print at the
same moment as the print-complete alert. Only the rising edge notifies.
Acknowledging still goes through POST /printers/{id}/clear-plate.

Two tests in test_printer_manager_status_broadcast.py asserted
_schedule_async.call_count == 2 for the setter. The new emission makes
it three on a transition, so they now assert that the persist and
broadcast coroutines are actually scheduled - which is the contract

Translated in all locales; wiki updated. Covered by backend and
frontend tests.
2026-07-28 13:36:55 +02:00
maziggy ed36eafbec Fix timestamps off by timezone offset in non-UTC containers (#504)
All backend timestamps used datetime.now() (server local time) or the
deprecated datetime.utcnow(). The frontend's parseUTCDate() assumes
timestamps without timezone indicators are UTC and appends 'Z', so
stored timestamps were off by the timezone offset when the container's
timezone wasn't UTC.

Backend: replaced datetime.now() and datetime.utcnow() with
datetime.now(timezone.utc) across 16 files (~80 call sites) for all
database fields and DB comparisons. Cosmetic timestamps (filenames,
user-facing local time formatting) intentionally left as local time.

Frontend: replaced 13 new Date(backendTimestamp) calls with
parseUTCDate() across 8 files to correctly interpret UTC timestamps.
2026-02-24 08:18:02 +01:00
Jeff Kletsky c45568bc7e Shut down MQTT relay and smart plug services explicitly
Existing code did not allow the MQTT relay to be shut down gracefully.

Moved _client.loop_stop() after _client.disconnect() call to allow
Paho to be notified to disconnect and shut down without reconnecting.

Added _client._disconnection_event to help prevent a race condition where
a disconnection is requested but the loop is immediately stopped.
Modify _client.disconnect() to take a timeout parameter (default: 0).
Wait in that routine for the disconnection event with the given timeout.

Apply same logic to MQTTSmartPlugService and add to shutdown sequence.

Shutdown the MQTT relay last in lifespan() with a hard-coded 2 sec timeout.

The disconnect timeout is also available to printer MQTT clients.
It is left to the default of 0 at this time. If later enabled,
it should be a configuration parameters, especially for large farms.

Fixes: #327

Signed-off-by: Jeff Kletsky <git-commits@allycomm.com>
2026-02-12 10:25:05 -08:00
maziggy 53bd4fadb3 Fix safe security findings: hashlib, log injection, broad excepts
- Add usedforsecurity=False to MD5 (AMS fingerprint) and SHA1 (git blob
  hash) calls to silence Bandit B303 / CodeQL weak-crypto findings
- Convert ~996 f-string logging calls to parameterized %s-style across
  55 files to prevent log injection (Bandit G201 / CodeQL log-injection)
- Narrow ~199 broad except Exception blocks to specific types:
  OperationalError for DB migrations, OSError for network/file cleanup,
  (OSError, ftplib.error_reply) for FTP, and targeted tuples for
  ZIP/XML/JSON parsing — 36 intentionally left broad (mixed async,
  re-raise patterns)
2026-02-06 11:37:59 +01:00
maziggy 00e3478a3e Add MQTT smart plug support for energy monitoring (Issue #173)
Add support for MQTT-based smart plugs that subscribe to external MQTT
topics and extract power/energy data from JSON payloads. This enables
integration with Zigbee2MQTT, Shelly, Tasmota discovery, and other
MQTT-enabled energy monitoring devices.

Features:
- New "mqtt" plug type alongside tasmota and homeassistant
- Subscribe to any MQTT topic with configurable JSON paths
- Extract power, energy, and state values using dot notation
- Optional multiplier for unit conversion (mW to W, etc.)
- Monitor-only mode (no on/off control) with teal color scheme
- Reuses existing MQTT broker settings from network configuration
- Energy data included in statistics and per-print tracking
- Full backup/restore support for MQTT plug configurations

Closes #173
2026-01-30 08:31:12 +01:00
maziggy 5d6ba0f875 Root cause: Frontend was firing multiple concurrent PUT requests when toggling MQTT, causing SQLite "database is locked" errors after 6-second timeout.
Fixes:
1. frontend/src/pages/SettingsPage.tsx - Added isSavingRef to prevent concurrent saves while a mutation is in progress
2. backend/app/services/mqtt_relay.py - Added 3-second timeout for MQTT connect to prevent blocking on unreachable brokers
2026-01-19 13:29:37 +01:00
maziggy 368999a234 Add MQTT publishing for external automation integration
New feature: Publish BamBuddy events to external MQTT brokers for integration
with Home Assistant, Node-RED, and other automation platforms.

Backend changes:
  - New MQTTRelayService (backend/app/services/mqtt_relay.py) with paho-mqtt
  - MQTT settings added to AppSettings schema (enabled, broker, port, auth, TLS)
  - New /settings/mqtt/status endpoint for connection status
  - Event hooks in main.py, print_queue.py, print_scheduler.py, maintenance.py, smart_plugs.py
  - PrinterInfo class and get_printer() method added to PrinterManager
  - MQTT reconfiguration added to backup/restore flow
  - Printer status throttled to 1 update/sec to avoid flooding

Frontend changes:
  - New "Network" tab in Settings (between Filament and API Keys)
  - FTP Retry settings moved from General to Network tab
  - MQTT configuration card with broker, port, TLS toggle, auth fields
  - Port auto-populates when TLS toggled (1883 ↔ 8883)
  - Connection status indicator (green/red dot) in tab and card header
  - Real-time status polling when on Network tab

Published topics:
  - bambuddy/status - Online/offline
  - bambuddy/printers/{serial}/status - Printer state (throttled)
  - bambuddy/printers/{serial}/print/* - Print lifecycle
  - bambuddy/printers/{serial}/ams/changed - AMS changes
  - bambuddy/queue/* - Queue events
  - bambuddy/maintenance/* - Maintenance alerts
  - bambuddy/smart_plugs/* - Plug state/energy
  - bambuddy/archive/* - Archive events

Tests:
  - Added MQTT settings and status endpoint tests

Closes #78
2026-01-13 12:31:45 +01:00