67 Commits
Author SHA1 Message Date
WATARIE fa25956738 Easy management of printer locations (groups) (issue #2962)- #2970 (#2995) 2026-10-03 14:28:35 +02:00
maziggy 8b5d8e3170 Add layers, job id, HMS faults and serial to the API-key printer status (#2919) 2026-09-30 11:45:31 +02:00
maziggy 033eff1254 Show Bambu's own HMS descriptions and the real alert level (issue #2728)
Document HMS levels, Bambu's descriptions and uncounted faults (issue #2728)
2026-09-28 13:57:02 +02:00
M2ABRAMSTANK 6c0292b09a fix(ams): show a parked drying command as not started instead of an active cycle (#3096) 2026-09-28 12:09:59 +02:00
maziggy 1ccaf74dd5 fix(install): sign the Python that macOS grants local network access to (issue #3114)
macOS attributes Local Network permission to a code signature and judges a
launchd-spawned process on its own, rather than letting it inherit the grant
of the Terminal that started it. Homebrew ships Python unsigned on Intel, so
there is no identity for the grant to attach to: every connection to a LAN
address is dropped with no error the application can log and no permission
prompt. The printer reads as unreachable and nothing says why, and the entry
in Privacy & Security cannot be made to work because it refers to an identity
that no longer resolves.

install.sh signs during a macOS install; update_macos.sh re-checks on every
update, because `brew upgrade python` installs a fresh unsigned binary under
a new versioned path.

Both sign only what is currently unsigned. That gate is load-bearing: on
arm64 the linker ad-hoc signs every binary and the identity is a hash of the
file, so re-signing would rotate it and revoke a working grant on each update.
A python.org build carries a real Developer ID and must not be downgraded for
the same reason.

The interpreter and the framework's Python.app are both signed. The first is
what sys._base_executable resolves to and what the reporter's TCC log names;
the second is what his fix actually targeted. Which one macOS attributes
could not be established from either, and signing both costs nothing.

-----

fix(diagnostics): name the macOS permission that silently blocks the printer (issue #3114)

The port checks reported all three ports unreachable while the subnet check
passed, and port_mqtt's fix text sent the reporter after firewalls and IP
addresses. On a macOS native install that pattern has a cause neither of
those covers: no Local Network grant, denied with no error and no prompt.

A new macos_local_network check, appended on macOS only so no permanently
dimmed row appears for anyone else. It passes when the control port answered,
which is proof the permission is in place and means the signature probe never
runs on a healthy diagnostic. Otherwise it probes the interpreter: an
unsigned one gets the repair that fixes it, a signed one gets System Settings
— the arm64 case, where the identity is a hash of the binary, so a Python
upgrade presents macOS with a new application and strands the old grant.

Always warn, never fail, and only once port_mqtt has already failed, so this
can never be why a green diagnostic turns red. A printer that is simply
switched off produces the same all-ports-dead pattern, which is why the
signature, not the pattern, is what earns the specific advice. An
undeterminable signature is reported as the generic case rather than as
unsigned: that advice rewrites a file in the user's Python installation and
must not be offered on a guess.
2026-09-19 16:03:52 +02:00
maziggy 9500c046c0 Ask which nozzle to feed when a Filament Track Switch is fitted
Load and Unload in the AMS slot menu did nothing on an H2C with the switch
fitted. The ams_change_filament command carries an optional extruder_id and
Bambuddy never sent it. That is correct on every printer without the switch,
and is what BambuStudio does there too -- each AMS is wired to one hotend, so
the firmware works the target out for itself and an explicit value would only
be a guess at something it already knows. Fit the switch and every AMS is
bound to one of its two inlets instead, either hotend is reachable from any
slot, and a command naming neither leaves the firmware nothing to act on. It
was discarded in silence.

Load now asks which hotend to feed, on the same terms as Bambu Studio: no
preselection, so a stray Enter cannot feed the wrong one, and the hotend
already fed from that very slot greyed out. Printers without a switch send a
byte-identical command and still load in one click. A switch fitted but not
yet set up -- any AMS still unassigned to an inlet -- refuses the load up
front rather than publishing one the firmware will drop, mirroring
DevFilaSwitch::IsReady, which likewise demands a switcher position on every
AMS.

Unload was addressed at the same time. It was aimed with tray_now, a single
value for the whole printer, so on any dual-nozzle machine with both hotends
loaded it unloaded whichever that field happened to name regardless of which
slot's menu was used. It now names the slot and resolves the holding hotend
from device.extruder.info, previously read for temperatures only. That
resolution is gated on the printer having reported two extruders:
single-nozzle machines do send the block, but nobody has read a single-nozzle
snow value off the wire, and staking every X1C, P1S and A1 unload on an
unverified encoding buys nothing where tray_now is already unambiguous.

Both new state fields ride the WebSocket and are in the broadcast key, and
both are computed in the REST status route as well -- that response is what
the page has before any push arrives, and leaving them at their defaults
would have told a correctly set-up machine that its switch was not set up.

Verified on H2C-1, AMS-A slot 3: loaded and unloaded from each hotend in
turn, all four correct. Covered by 18 MQTT unit tests, 4 status-dict tests,
7 integration tests and 6 component tests.

Two known stragglers, both deliberately left alone. Load on an AMS-HT slot
has never worked -- an HT unit is addressed by its unit id rather than
ams*4+slot, which these endpoints do not accept -- so unload there keeps the
printer-wide form it always used instead of gaining a slot it cannot name.
And a slot's K-profile still follows the AMS's plumbing rather than the
nozzle just loaded, so loading to the far hotend leaves the other one's
calibration bound; that is the same per-nozzle problem the filament and
K-profile redesign is scoped to fix.
2026-08-26 12:04:42 +02:00
maziggy 6988a30eae Carry a fault's description in the status response (issue #2926)
The HMS catalogue has been in the backend all along and the status
response never carried it, so every consumer that wanted to tell a user
why a print halted resolved the same 853 codes from its own duplicate of
the same sentences -- this repo's Python table, the frontend modal's, and
at least one third-party client whose catalogue exists purely because the
server would not say. Each ages separately, and a relay watching a
printer could only manage "your printer needs attention" while the server
already knew it was "Filament ran out. Please load new filament."

hms_errors[] entries now carry a description, defaulting to null so a
client that has never seen the field is unaffected.

It is resolved where the fault is parsed rather than at the boundary that
prompted the request, because there are three serializers of a fault, not
one: the status response, the WebSocket broadcast, and the completion
payload the queue's failure reason is built from. Adding it to only the
first would have handed half the feature to a relay watching the stream,
which is the likelier consumer of the three. The queue's failure reason
now quotes the resolved sentence instead of looking the code up a fourth
time, and the notification path reads it rather than re-deriving. That
they cannot report different text for one fault is the point, and a test
asserts they agree.

describe_fault is the single mapping from either code shape onto the
table. An 8-char print_error is the catalogue's MMMM_EEEE key with the
separator removed -- the parser derives full_code and that key from the
same 32-bit value -- so it resolves exactly. A 16-char hms[] identifier
is tried whole and then collapsed to its first and last groups.

That collapse is lossy, and keeping it was the decision worth making
carefully. #2728 counts 65 documented faults falling onto 0300_0001
alone, so a hit can attribute a neighbour's sentence to this fault, and
refusing it looks like the stricter reading. It is not: the notification
path, the queue's failure-reason helper and the frontend modal have all
resolved hms[] faults this way for as long as they have existed, and it
resolves real ones -- a 0500_4038 nozzle mismatch arrives in that shape.
Declining to collapse would have stopped describing faults that are
described today, silently suppressed the notifications they raise, and
left this field null while the UI showed text for the same fault.
Narrowing it belongs with #2728, where both key spaces can move together.

So the lookup is exactly what it was, verified rather than asserted:
a test walks every catalogue code in both fault shapes across all three
alert levels and checks the result against the derivation this replaces.
A future change to the lookup cannot quietly stop notifications firing.

The catalogue ships one language, so the field is English and
unlocalized, which the schema and the API reference both say next to it.
The camwall feed is deliberately left alone -- it is code-only because
its token travels in a URL on a screen, and a readable sentence discloses
more than the camera picture already does. The frontend keeps resolving
its own text: switching it would change what filterKnownHMSErrors counts
across eight call sites, which is #1840 and #2728's argument to have.

HMSError.message goes with this -- a text field that was never set or
read anywhere, and an invitation to populate the wrong one now that a
live description sits beside it.

-----

Record a failure code the user can actually look up

The queue's failure reason formats a fault's module and error into
MMMM_EEEE, and that one derivation never masked the error to 16 bits. A
fault arriving from the printer's hms[] array carries its alert level in
the code's high half, so the label came out as 0500_24038 -- five digits
in a group that has four. It is not a code anyone can find on Bambu's HMS
index, and because it matches no catalogue key the sentence explaining
the failure was dropped along with it, leaving the bare number alone.

The nozzle-size mismatch behind #1111 is exactly such a fault. Reported
one way it read "[0500_4038] The nozzle diameter in sliced file is not
consistent with the current nozzle setting"; reported the other, the same
physical fault read "[0500_24038]" and nothing else.

There is already a helper that gets this right, used by the archive's own
failure-reason lookup, so this calls it instead of keeping a fourth copy
of the derivation. It also takes the raw integer code the MQTT payload
carries, which the local version only handled as a string.
2026-08-24 09:47:39 +02:00
Sean K 55cc64c87d Add printer video downloads and range selection (#2853) 2026-08-22 13:22:56 +02:00
maziggy 7a42e0a7e5 Show which Filament Track Switch inlet each AMS feeds
With a switch fitted, an AMS is not wired to a nozzle any more. It is
plumbed into one of the switch's two inlets and reaches both nozzles
through it, so every unit reports its extruder as "not fixed" (0xE) and
ams_extruder_map comes back empty on these machines.

The printer card had nothing to fall back on but the AMS unit number, so
AMS-A was badged R and AMS-B was badged L purely because their unit ids
are 0 and 1, a third unit got no badge at all, and every one of those
labels was wrong. The SpoolBuddy assign modal had the same fallback in a
worse form, mapping anything that was not extruder 1 to R.

The binding turned out to need no new telemetry. BambuStudio reads it out
of bits 24-27 of the same AMS info string we already parse for the AMS
type and the extruder id -- 0 is In-B, 1 is In-A -- and it is only
meaningful when a switch is installed, because without one 0xE really
does mean an uninitialised unit and those bits carry nothing. That gates
the read, which in turn forced the switch block to be parsed before the
AMS block: _handle_ams_data runs early in _process_message and
_update_state only much later, so the binding was lost on every frame
that carried both. _parse_fila_switch is split out and called first, and
left in _update_state as well so that stays a complete absorb step.

The badge keeps L and R rather than A and B, because the lettering is
familiar and matches the physical layout. It is a different colour from
the plain nozzle badge, and its tooltip names the inlet in full, since
the letter is the inlet's position and not a claim about which nozzle
that AMS feeds -- the switch can route either inlet to either outlet. An
AMS still reporting a real extruder id keeps its ordinary badge, which
BambuStudio also treats as authoritative over any switch binding, and a
switch that has been fitted but not yet set up on the printer shows
nothing rather than a guess.

The print dialog's slot dropdown gets the same label. It replaces a
left/right hint that never once rendered: ftsExtruderForSlot compared
snow-encoded in[] values against global tray ids and could not match.
Decoding it correctly would not have saved it -- the firmware reports
which slot sits in each inlet and which nozzle each outlet feeds, but
never which inlet is currently paired with which outlet, so no per-slot
nozzle can be derived. That function is gone rather than fixed.

The dialog also points out when every filament a print needs sits behind
one inlet. Bambu's own guidance is that this is legal but slow: a change
between two filaments on the same inlet retracts the outgoing spool all
the way back to its AMS before the next can be fed up the shared tube,
where a change across the two inlets only retracts as far as the switch.
All on one inlet means every change in the job takes the slow path, and
moving a single spool fixes it. So it advises, it does not block.

Both views update live. Two things were stopping that. fila_switch and
ams_switch_inlet were absent from printer_state_to_dict, and the frontend
shallow-merges each WebSocket push over its cached status, so a field the
push omits keeps whatever the last full fetch left behind. And the
broadcast dedup key had no term for either, so "Join IN-B" on the printer
screen moved nothing: the binding is not in the tray component of that
key, and it is not in the AMS change-hash either, which covers tray
fields only and must stay that way because it drives Spoolman sync.

Assigning an AMS to an inlet remains printer-side. BambuStudio can read
the binding and has no command to write it -- its switch class is parse
and getters only, and the recommended-arrangement popup draws and
publishes nothing -- so there is no wire format for us to copy.

Adding the two fields to PrinterState broke four test modules whose
SimpleNamespace stubs predate them. The stubs are fixed rather than the
production reads made defensive: the real dataclass always carries both,
and a getattr in the dedup key would silently stop tracking the field if
it were ever renamed.
2026-08-16 15:09:00 +02:00
maziggy 18938a10ee fix(kprofiles): stop reporting rejected K-profile writes as saved
Saving a K-profile was fire-and-forget. set_kprofiles_batch published
and returned True, and the printer's extrusion_cali_set answer was
logged at DEBUG and dropped, so a write the printer refused was
reported to the user as saved (#2718, reporter @jmoore-skild).

The reason it could not simply be gated on: the answer itself was
wrong. Single-nozzle firmware returned result:"fail" with
reason:"invalid tray_id" on writes that demonstrably applied.
Measured against an X1C and an H2D over MQTT, the cause is the
tray_id:-1 Bambuddy itself put in the payload. Sending three
otherwise identical writes isolated it: tray_id:-1 fails, tray_id:0
succeeds, and cali_idx:-1 is accepted either way, so only that one
field is at fault. The H2D ignores the value entirely; the X1C
validates it, complains, and applies the write anyway. BambuStudio
always sends a real tray_id and defaults it to 0 for a manually
entered profile.

With tray_id:0 the acknowledgement is honest, and the printer echoes
back the sequence_id we sent -- confirmed for extrusion_cali_get,
_set and _del on both printer classes -- so it can be matched to the
write that caused it. Writes now return their sequence_id and the
routes await the verdict, turning a real failure into an error that
carries the printer's own reason. A printer that stays silent is
still treated as success: no answer is not evidence of refusal, and
firmware that never answers must not turn every save into an error.

Raises the ack to INFO. It sat at DEBUG, so the one line that
explains a failed save was absent from every support bundle -- the
same reasoning that put ams_filament_drying at INFO for #1447.

Also fixes extrusion_cali_set building its payload from
str(self._sequence_id) without incrementing first, reusing the
previous command's id. Harmless while nothing correlated on it,
fatal now that the write path does.

Adds supports_nozzle_flow_type() for the Standard / High Flow choice,
which the K-Profiles UI previously showed as "Not reported by
printer" -- not a value anyone can save. Most printers omit the
nozzle identity from their calibration table entirely, and the slicer
treats that as Standard rather than unknown; Bambuddy now does the
same and keeps the choice editable. The field is hidden only where
the model ships a single nozzle variant, using the slicer's own rule
(len(nozzle_volume) // len(nozzle_diameter) > 1 over the machine
preset) evaluated across every bundled Bambu profile. That puts only
A1, A1 Mini and A2L on the hidden side -- it is not the single-
versus-dual-nozzle split, since P1P, P1S, P2S, X1, X1C, X1E and H2S
are all single-nozzle and all carry two variants. Editing a profile
also no longer writes back an empty nozzle_id.

Wiki records that on printers which omit the field the chosen flow
type is discarded by the firmware and reads back as Standard, in
Bambu Studio as well, so it does not get filed as a bug again.
2026-08-01 10:35:22 +02:00
Gabe 9ee162d51a feat(printers): expose P2S/X2D accessory fans (left aux + exhaust)
The P2S/X2D have two fans bambuddy didn't fully handle. On the P2S both are
add-on kits; on the X2D they ship from the factory.

1. Left auxiliary part cooling fan — not shown or controllable. It is reported
   ONLY as device.airduct part id 10 (raw id 160 >> 4; FAN_REMOTE_COOLING_1 in
   Bambu Studio's DevFan::ParseV3_0) and is never mirrored into a flat
   big_fanX_speed field, which is why it was invisible. This is the gap
   identified in #2576, where the single 'Auxiliary' fan (big_fan1 / M106 P2)
   only reaches the right-hand aux fan.

2. Chamber exhaust fan — shown on every P2S labelled 'Chamber Fan'. On P2S/X2D
   Bambu's firmware/UI (and Bambu Studio's FAN_CHAMBER_0_IDX) call it 'Exhaust',
   and it is a kit on the P2S rather than built in.

Both are now detected from device.airduct.parts, which lists only the fans that
physically exist, so each tile appears only when the hardware is present.

- bambu_mqtt: parse airduct part 10 -> left_aux_fan_speed (None when absent) and
  part 3 presence -> exhaust_fan_present; set_fan_speed() accepts index 10 plus a
  set_left_aux_fan() helper
- schema / status route / printer_manager broadcast / mqtt_relay expose both fields
- POST /printers/{id}/fan-speed accepts fan=aux2 -> M106 P10, the command Bambu's
  official P2S machine profiles use
- frontend: 'Left Auxiliary Fan' tile shown when reported; big_fan2 tile labelled
  'Exhaust' and presence-gated on P2S/X2D, unchanged 'Chamber Fan' elsewhere
- i18n: leftAuxiliary + exhaust for all 12 locales

Verified fan -> field map on a live P2S (fw 01.02.00.00), stable across cooling
and heating airduct modes:
  Part cooling -> cooling_fan_speed / airduct id 1  (built in)
  Aux          -> big_fan1_speed    / airduct id 2  (built in)
  Exhaust      -> big_fan2_speed    / airduct id 3  (kit)
  Left aux     -> airduct id 10 only (kit; forced off in heating by mode config)

Tests: airduct id-10 parsing (raw 160 -> id 10, not literal 160), id-3 presence,
base-P2S absence, diff-push survival, clamping, malformed entries, M106 P10
emission, invalid-index rejection; fan-speed API aux2->10 mapping; frontend tile
presence and labelling per model/kit.
2026-07-28 11:16:22 -05:00
maziggy e77e10896f feat(ams): name the expected slot when a paused print hits an AMS runout (#2587)
The firmware's runout HMS text says "insert into the same AMS slot", which is
wrong under AMS Filament Backup: the firmware won't re-accept the depleted slot
and advances to the next compatible one. Bambuddy parsed print.ams.tray_now only
and dropped tray_tar/tray_pre, so the expected slot never reached the UI.

Capture tray_tar/tray_pre on PrinterState and, while paused, resolve them to
global tray IDs (expected_tray/previous_tray) on both the REST and WebSocket
status payloads via a shared resolver: single-AMS passthrough, multi-AMS
snow-mapping resolution, AMS-HT/external passthrough, and an honest null when the
slot can't be placed. The AMS graphic highlights the expected slot (amber) and
the ran-out slot (red); the HMS modal re-describes runout codes to name both,
falling back to "check the printer" when unresolved. Runout copy translated in
all 11 locales.

Reporter @Jostxxl confirmed tray_pre=1/tray_tar=2 during the pause (ran out in
Slot 2, printer expected Slot 3).
2026-07-18 13:06:01 +02:00
maziggy ca3f6e5ee0 fix(drying): P1 AMS drying is screen-only — stop offering it (#2533)
The reporter found what his P1S was doing, and it is in Bambu's P1 manual:
"P1S connected AMS drying functions may only be controlled from the P1S screen."
The firmware acks ams_filament_drying with result: success and then discards it,
which is why three commands on an idle printer left the AMS 2 Pro at dry_status 0.
No command can start a cycle on a P1, on any firmware, so don't offer one.

supports_drying() now excludes the P1 series outright, replacing the 01.08+ gate
carried since #292 — that version is when P1 firmware gained AMS 2 Pro support,
not remote drying, and it was never checked against a live P1. Both drying routes
refuse with a specific 400 instead of publishing a message the printer will drop;
queue and ambient auto-drying skip P1s via the same helper.

A new drying_screen_only flag keeps the control on the card, disabled, saying why
— a P1 owner needs to learn where to dry, not watch the button disappear. A cycle
started at the printer still shows with its countdown; only Stop goes away, since
a P1 ignores stop exactly as it ignores start.

Also corrects the wiki firmware matrix, which listed P1P/P1S as supported and
(separately) P2S/H2S/H2C as unsupported. 8 tests.
2026-07-11 09:33:52 +02:00
maziggy f6c6cfbad3 fix(ams): show "?" not "Empty" for non-RFID spools using tray_exist_bits (#2527)
A spool with no readable RFID was reported by the standard AMS with an empty
tray_type and state=9 — structurally identical to a truly-empty slot at the
tray level — so the AMS card rendered it "Empty" while Bambu Studio correctly
showed "?". The authoritative "a spool is physically here" signal is firmware's
AMS-level tray_exist_bits bitmask (what Studio uses), but Bambuddy inferred
emptiness from the per-tray state/tray_type. Confirmed from the reporter's
bundle: tray_exist_bits=f (all four slots present) with tray_is_bbl_bits=5
(only slots 0,2 Bambu) — the present-but-non-Bambu slots were the ones shown
Empty. Supersedes closed #1838.

apply_tray_exist_bits() already parses the bitmask to clear stale fields on
absent slots; it now also annotates each slot with an authoritative `exists`
bool, gated behind a new annotate_exists flag so only the printer-card path
sets it. The VP bridge leaves it off, so the `exists` key never reaches the
slicer wire format. `exists` flows through the AMSTray schema/serialization to
the frontend, where getEmptySlotKind() uses it: exists===true + no tray_type
-> "?" (present, unconfigured), exists===false -> "Empty", exists absent ->
the previous state=9/10 heuristic (AMS-HT and missing-bitmask paths unchanged).
H2D/X1C already reported present-unknown slots with a non-9 state and took the
"?" path; with the fix they reach it via `exists` and are unaffected.
2026-07-09 09:27:13 +02:00
maziggy d4ad41d850 fix(hms): action buttons actually reach the printer (#1830)
Three distinct bugs combined into one user-facing failure: clicking
Stop / Problem-solved-and-resume / Ignore-and-resume returned 200 OK
but the printer didn't act, modal stayed up, print stayed paused.
Verified by injecting candidate command shapes on device/<sn>/request
against a live H2D paused on a wrong-plate HMS (print_error=0x05008051).

(1) hms_resume / hms_stop dispatched the "err"-bearing shape that
BambuStudio doesn't actually send; Bambu firmware silently rejects it.
Both now send the plain shape ({"print":{"command":"<x>","param":"",
"sequence_id":"0"}}). PAUSE -> FAILED in 1.7s for stop, PAUSE -> RUNNING
in <2s for resume.

(2) IGNORE_RESUME mapped to idle_ignore, which is BambuStudio's
"dismiss a warning" command and only works for non-pause warnings.
hms_ignore now branches on state.state == "PAUSE": paused -> plain
resume; not-paused -> idle_ignore with the full-length err.

(3) 64-bit hms[]-array faults were truncated to a non-matching err.
short_code in _parse_status discarded 32 of the 64 identifier bits, so
the firmware didn't match it to the active fault. HMSError.full_code
now carries the canonical hex identifier (16 chars for hms[] faults,
8 chars for print_error faults). Catalog lookup tries 16-char first,
falls back to 8-char. HmsActionBody.print_error pattern relaxed to
^[0-9A-Fa-f]{8}([0-9A-Fa-f]{8})?$.

(4) execute_hms_action returned publish-success as success, masking
every silent-rejection bug above as 200 OK. Route now snapshots
(state.state, len(state.hms_errors)) before dispatch, awaits
HMS_ACTION_ACK_WAIT_SECONDS (default 2.5s, module-level so tests
override), and returns 502 with "Printer did not acknowledge HMS
action within 2.5s" if state didn't move.
2026-06-27 09:18:57 +02:00
Zelda 3ddf8d847e [Feature]: HMS Actions (#1743) 2026-06-26 14:40:25 +02:00
maziggy fd61812d01 feat(drying): show active-cycle filament + target temperature on the AMS drying badge
Bambu's per-tick AMS push carries only the dry_time countdown — the
  filament name and target temperature the user chose are never echoed on
  the wire. The AMS card had no source of truth for them and rendered the
  bare "Drying · 11h 35m left". The badge now shows
  "Drying · PETG @ 65°C · 11h 35m left", matching the cycle the user
  actually started.

  BambuMQTTClient caches {ams_id: {filament, temp}} on send_drying_command
  (mode=1), clears on mode=0 and on the dry_time falling edge to 0 — the
  same per-AMS edge detector that drives the smart-plug-after-drying
  callback. PrinterManager.get_drying_targets exposes it, the four
  printer_state_to_dict call sites thread it through, AMS schema gains
  dry_target_temp + dry_filament, and routes/printers.py builds the same
  fields into the manually-constructed AMSUnit response.

  When no cached target exists (drying started in a previous backend
  lifetime, or initiated outside Bambuddy), the badge falls back to the
  first loaded tray's tray_type + RFID-recommended drying_temp — the
  heuristic the popover already uses to seed defaults.

  i18n: printers.drying.targetSummary = "{{filament}} @ {{temp}}°C" in
  all 11 locales. Parity check 5356 leaves per locale.

  Note: a user reported the H2D's own physical display still labels the
  cycle by the loaded tray's filament (e.g. "PLA" instead of the
  Bambuddy-requested "PETG"). The wire payload is correct end-to-end —
  journalctl shows filament: "PETG" sent and result: success ACKed — and
  the badge in Bambuddy's own UI now reflects what we actually sent,
  independent of the firmware's display choice.
2026-06-25 13:27:32 +02:00
maziggy 8d6f701f1d feat(drying): continue drying while printing + gate rotate-spool when tray loaded (issue #1816)
Continue Auto-Drying while a print is running on capable hardware.
  New Settings > Print Queue > "Continue drying while printing" toggle
  (default OFF). Extends _check_auto_drying in print_scheduler.py to
  evaluate running printers when supports_drying_while_printing(model,
  firmware) returns true. Strict allowlist verified per Bambu wiki
  release notes for "Print While Drying" / "printing while filament is
  drying": H2D 01.03.00.00+, H2C/H2S/P2S/H2D Pro 01.02.00.00+, X2D/A2L
  01.01.00.00+, X1C 01.11.02.00+. P1*, A1, A1 Mini, X1 (non-C), X1E
  intentionally excluded. Mid-print drying temperature is capped at
  max(40, preset_temp - 5) to protect spools from heat damage inside the
  hot enclosure during a print, matching Bambu's own "lower drying
  temperature during printing" guidance.

  Rotate-spool toggle in the drying popover is now disabled when any tray
  in the targeted AMS has filament threaded into the feed tube
  (tray.state === 11). The whole AMS rotates as one mechanism, so a
  single loaded slot locks the entire unit. Previously the toggle was
  always clickable and the firmware rejected with dry_sf_reason=[3]
  (ConsumableAtAmsOutlet) after the click. The first cut keyed on the
  printer-level tray_now but missed the H2D's typical post-print state
  where tray_now resets to 255 while filament stays in the tube — the
  per-tray state field reports it correctly. Submission also clamps
  rotateTray off so a stale-true state from a previous AMS can't leak
  through.

  Backend: supports_drying_while_printing in printer_manager.py covers
  display names and internal SSDP/MQTT codes (O1D, O1E/O2D, O1C/O1C2,
  O1S, N6, BL-P001, N7, N9). New print_drying_enabled boolean in
  settings schema. Frontend: toggle on SettingsPage, gate + clamp on
  PrintersPage drying popover using existing amsData cache. i18n: 3 new
  keys x 11 locales, no English fallback. Tests: 7 cases on the gate
  matrix (TestSupportsDryingWhilePrinting), 4 cases on the scheduler
  mid-print path (TestMidPrintDrying), 9 cases on the rotate gate state
  transitions. Full backend pytest -n 30 green (4251/4251), ruff clean,
  frontend npm run build clean, i18n parity 5355 leaves per locale.
2026-06-25 12:47:26 +02:00
maziggy b1cb26f6ee feat(ams-backup): add status badge + toggle, fix prefer-lowest (#1766)
Two tightly-coupled deliverables in one drop -- a new AMS Filament Backup
  status/control surface, and the #1766 fix that depends on it.

  Added -- AMS Filament Backup status + control
  - Parse bit 18 of top-level print.cfg into PrinterState.ams_filament_backup
    on every push_status. Verified against OrcaSlicer source
    (DeviceManager.cpp:4961) and a live H2D ON/OFF capture. Tri-state
    (None = A1 family / pre-cfg push) preserves today's behaviour.
  - Hold-timer guard (3 s) prevents stale frames from flickering the badge
    back to the printer's old cfg after a user-initiated toggle.
  - POST /printers/{id}/ams-backup toggle, set_ams_filament_backup() client
    method calling _set_print_option("auto_switch_filament", enabled).
  - GET /printers/{id}/inventory-remain endpoint exposes the same map the
    dispatcher uses (internal and Spoolman modes both work uniformly).
  - Small icon badge in the printer card's "Filaments" section header
    (placement reads as printer-wide because the cfg bit is printer-wide,
    not per-AMS). Click to toggle, success toast.
  - 5 i18n keys x 11 locales for the badge UI.

  Fixed -- #1766: prefer_lowest didn't pick lowest, ignored backup state
  - Backend gate in _compute_ams_mapping_for_printer: coerce prefer_lowest
    to False when status.ams_filament_backup is False; log the skip.
  - New effectivePreferLowest(setting, backup) helper applied at every
    frontend sort entry point: single-printer PrintModal, multi-printer
    hook per-printer, PrinterSelector InlineMappingEditor, FilamentMapping
    standalone editor (the last had NO preferLowest awareness at all
    before this change).
  - New preferLowestSortKey(f, inventoryByTrayId) mirrors backend's two-tier
    key exactly, including the banding tie-break (regular AMS < AMS-HT <
    external) so the client-side pre-compute matches the dispatch-time pick.
    An earlier draft used a flat `amsId * 4 + trayId` priority which gave
    external slots (ams_id = -1) a NEGATIVE priority -- caught in code
    review before commit.
  - Settings -> Filament -> "Prefer lowest remaining filament" gets an
    explanatory note about the printer-side AMS Backup dependency, with
    i18n key in all 11 locales.
2026-06-20 12:07:20 +02:00
Ed 0f99b54d7e feat: Update printer card UI for structure and readability (#1661) 2026-06-18 11:46:07 +02:00
maziggy 9a432f0050 Restrict printer secrets to update-authority callers
GET /api/v1/printers/ and /api/v1/printers/{id} return access_code
  only when the caller holds PRINTERS_UPDATE. Adds PrinterResponseWithSecret
  as the elevated response shape; PrinterResponse no longer carries the
  field. Auth-disabled single-trust mode preserved.
2026-06-18 07:36:16 +02:00
maziggy 76e327f4a1 feat: connection diagnostic for "printer won't connect" triage
A triage review of the last 200 closed issues found ~1/3 were
  user-side setup errors — printer not in LAN developer mode, blocked
  ports, Docker bridge networking, wrong access code, cross-subnet —
  each costing a multi-round-trip support exchange.

  Add a Connection Diagnostic that runs those checks automatically:
  - backend/app/services/printer_diagnostic.py: TCP probes of MQTT
    8883 / FTPS 990 / RTSPS 322, LAN developer mode, Docker network
    mode, printer/host subnet match, MQTT credential class; each
    check returns pass/fail/warn/skip with a localized fix.
  - Routes: GET /printers/{id}/diagnostic (saved printer) and
    POST /printers/diagnostic (pre-save Add-Printer flow).
  - ConnectionDiagnostic.tsx: modal + shared checklist, surfaced from
    the printer card actions menu, an offline-printer quick button,
    the Add-Printer dialog, and a new System-page section.
  - The in-app bug reporter scans configured printers when the form
    opens and always shows the result inline — a healthy confirmation,
    or the detected problem and its fix.
  - config.yml troubleshooting link repointed to the rendered wiki
    page; bug_report.yml gains a diagnostic checkbox.

  Diagnostic strings translated across all 8 locales. Backend service
  unit tests (15) + frontend modal tests (3). Ruff clean, frontend
  build clean, i18n parity green.
2026-05-21 11:00:59 +02:00
maziggy 01787eb1e6 fix(printers): normalize serial numbers + diagnose connect-but-no-reports (#1465)
Reporter's H2C connected over MQTT+TLS but every status field stayed
  unknown. Root cause was layer-8: the MQTT broker is the printer, it
  authenticates on the access code and SUBACKs any topic string, so a
  wrong or mis-cased serial connects fine and silently receives nothing
  (the report topic device/<serial>/report is case-sensitive; Bambu
  serials are uppercase). Bambuddy stored and used the serial verbatim.

  - schemas/printer.py: field_validator strip()+upper()s serial_number on
    create, rejects blank-after-strip. The subscribed topic now always
    matches the printer's correctly-cased one.
  - bambu_mqtt.py: count report-topic messages per connection; when a
    stale reconnect fires with zero reports received, log a one-shot
    hint pointing at the serial number instead of looping silently.
2026-05-21 08:30:17 +02:00
maziggy abc8e97050 feat(camera): optional snapshot URL override for external cameras (#1177)
go2rtc and several IP cameras still emit a warm-up / black frame on every
  fresh MJPEG connection — even with the v0.2.4b2 warm-up-skip fix it
  slipped through intermittently for @nkm8's setup. His own bisect named
  the clean solution: go2rtc exposes /api/frame.jpeg as a dedicated
  single-frame endpoint that never returns the encoder's stale keyframe.

  Adds an optional external_camera_snapshot_url column on printers. When
  set, every single-frame capture path (snapshot endpoint, [SNAPSHOT]
  notification thumbnails, [PHOTO-BG] finish photo, layer timelapse,
  Obico ML, plate-detect / calibrate-plate) routes through _capture_snapshot
  on the override URL via plain HTTP GET, bypassing the warm-up dance.

  Live view stays on the configured stream URL — only single-frame
  captures use the override. Override is camera-type-agnostic. SSRF guard
  applies (existing _sanitize_camera_url allowlist). Empty string treated
  as unset.

  Settings UI: new "Snapshot URL (optional)" input + Test button under
  External Cameras, hidden for camera_type=snapshot since the live URL is
  already a single-frame source. en + de fully translated; 6 other locales
  seeded with English copy.

  5 backend tests pin the routing contract; 3 frontend tests pin the
  input + debounced PATCH. Documented in
  bambuddy-wiki/docs/features/camera.md with the go2rtc example.
2026-05-03 07:59:02 +02:00
maziggy b45ca2a662 feat(printer): support Filament Track Switch (FTS) accessory in print modal (#1162)
The FTS routes any AMS slot to either extruder, so AMS info reports
  bits 8-11 = 0xE (uninitialized) and ams_extruder_map ends up empty.
  The print modal's per-nozzle dropdown filter then hides every loaded
  slot, leaving the user with an empty filament dropdown.

  Detection: parse print.device.fila_switch from MQTT push_status into a
  new FilaSwitchState dataclass on PrinterState; surface it through the
  GET /printers/{id}/status response as a nullable FilaSwitchResponse.

  Frontend: useFilamentMapping and FilamentMapping skip the per-extruder
  filter when fila_switch.installed is true. Slots currently fed into a
  track display an [L]/[R] routing badge in the dropdown so the user
  can see where the FTS is currently routing them.

  Tests: 4 backend unit (TestFilamentTrackSwitchDetection), 2 backend
  integration (status route), 2 hook regression, 2 component regression.
2026-04-29 16:18:45 +02:00
maziggy fa1c46d9a5 feat(printers): show plate name on card for multi-plate active prints (#881)
When two printers were running different plates of the same multi-plate
  3MF, the Printers page cards displayed the same file name on both and
  there was no way to tell them apart. The Queue view already had this
  information by cross-referencing the archive's plate list; the card
  didn't have the linkage.

  Expose `current_archive_id` (resolved by matching the MQTT `subtask_id`
  against `PrintArchive.subtask_id` — the bridge introduced in #972 for
  restart-resume) and `current_plate_id` (parsed from `gcode_file` by a
  new shared `parse_plate_id` helper) on the status endpoint. The helper
  is also called from the WebSocket push path so plate transitions
  reflect within 100 ms instead of waiting 30 s for the next REST poll;
  the archive id itself stays REST-only since it's stable for the life
  of a print and shouldn't make the push path touch the DB.

  The card fetches plate metadata via the same `api.getArchivePlates()`
  call QueuePage uses — shared React Query cache keeps it cheap across
  polls — and renders the actual plate name (or a "Plate N" fallback)
  only when `is_multi_plate` is true. Single-plate prints stay clean.
  Falls back to the previous `plate_N.gcode` regex path when there's no
  archive linkage (e.g. prints started directly from the printer LCD).

  Tests cover the plate-id extraction across Bambu Studio path shapes
  (backend parse_plate_id, printer_state_to_dict wiring) and the label
  override precedence in formatPrintName (frontend).
2026-04-21 09:46:42 +02:00
maziggy 8af0966e68 feat(printers): airduct mode + status badges + force refresh on printer card
Surface four Home Assistant-style controls on the Printers page card:

  - SD Card badge in the top status row (green / red, icon-only).
  - Enclosure Door badge in the top status row (green / yellow, icon-only).
    Detection per printer family — X1/X1C/X1E read home_flag bit 23, all
    others read top-level `stat` (hex string) bit 23 — so X1 firmware that
    does not flip stat bit 23 stops false-triggering "open". WebSocket
    status-change dedup key now includes door_open so toggling the door
    alone publishes a push, no 30s REST-poll wait.
  - Airduct Mode badge beside the speed control (cooling / heating)
    for P2S/H2D/H2C/H2S; one-click dropdown calls the existing
    set_airduct MQTT command via a new POST /printers/{id}/airduct-mode
    route.
  - Force Refresh entry in the kebab menu — calls the existing
    /printers/{id}/refresh-status endpoint to request a pushall snapshot
    without forcing a reconnect.

  Tests: door-open parsing (X1 home_flag, non-X1 stat, ignore mismatched
  source, invalid hex) and airduct route (validation, not-connected,
  success, failure).
2026-04-13 12:50:17 +02:00
maziggy de7fff0be4 fix: persist plate-clear gate so Auto Off power cycles can't bypass the queue confirmation (#961)
With Auto Off enabled and another job queued, the smart plug cut power when a
  print finished and immediately re-powered the printer because the scheduler
  saw pending items. The printer booted fresh into IDLE and the next job
  auto-dispatched, bypassing the "Clear Plate & Start Next" confirmation.

  Root cause: the plate-clear gate lived only in PrinterManager._plate_cleared
  (in-memory set) and _is_printer_idle treated IDLE as unconditionally idle. On
  power cycle the in-memory flag was lost and the IDLE-on-boot state skipped
  the gate entirely.

  Fix:
  - Replace the in-memory flag with an awaiting_plate_clear column on the
    printers table, rehydrated into the PrinterManager at startup.
  - Set the flag in on_print_complete for completed/failed prints (not user
    cancellations); clear it on ack and on scheduler dispatch.
  - _is_printer_idle now short-circuits to not-idle whenever require_plate_clear
    is on and the flag is set, regardless of the currently reported state —
    so the gate holds through power cycles, Bambuddy restarts, and the printer
    booting back into IDLE.
  - /printers/{id}/clear-plate no longer requires the printer to report
    FINISH/FAILED; it accepts the ack whenever the flag is raised.
  - Frontend widgets (PrinterQueueWidget, Layout, BulkPrinterToolbar) gate on
    the flag rather than reported state.

  Tests: added regression tests for IDLE+awaiting=True (the #961 case) and
  full DB round-trip tests for the persistence layer.
2026-04-13 09:12:12 +02:00
maziggy c9efa4b8bb Fix stale AMS slot data and empty slot button visibility (#784)
Some printers (e.g. H2D) only send {id, state} in incremental MQTT
  tray updates — no tray_type, tray_color, or other fields. When
  filament is unloaded (state changes from 11 to 10), the old tray
  data persisted indefinitely because the merge logic only updates
  fields present in the incoming message.

  Backend:
  - Detect tray state != 11 without tray_type in incremental updates
    and clear stale tray data (bambu_mqtt.py)
  - Expose tray `state` field via REST API and WebSocket broadcasts
    (printer.py schema, printers.py route, printer_manager.py)
  - Include AMS tray content in WebSocket dedup key so load/unload
    transitions trigger broadcasts (main.py)

  Frontend:
  - Add `state` to AMSTray interface (client.ts)
  - Show configure/assign buttons for state=10 (spool present, not
    loaded) but hide for state=9 (truly empty) on AMS/HT slots
  - Hide fill level bar on empty slots

  Tests:
  - 5 new tests covering state-based clearing, preservation, reload,
    and idempotency
2026-03-24 16:03:34 +01:00
maziggy fe3c1983af Add camera image rotation option (#672)
Per-printer camera rotation (0°/90°/180°/270°) for cameras mounted
  in portrait or upside-down. CSS rotation for live views, Pillow
  rotation for notification snapshots. Setting visible in external
  camera config when enabled.
2026-03-17 13:59:01 +01:00
maziggy cffba4a911 Add queue auto-drying, configurable drying presets, and AMS PSU detection (#292)
Queue auto-drying: scheduler automatically starts drying on idle printers
  with scheduled queue prints when AMS humidity exceeds the configured
  threshold. Uses conservative parameters (lowest temp, longest duration)
  for mixed filaments. Drying stops when humidity drops below threshold
  (30-minute minimum prevents oscillation), when scheduled items are
  removed, or when the feature is disabled. Optional "block queue" mode
  delays the next print until drying completes.

  Configurable presets: temperature and duration per filament type,
  editable in Settings → Print Queue, used by both manual drying popover
  and queue auto-drying. Separate presets for AMS 2 Pro (n3f) and AMS-HT
  (n3s) reflecting different heating capabilities.

  PSU detection: drying button disabled with tooltip when dry_sf_reason
  indicates insufficient power. Parses drying status bits and dry_sf_reason
  from AMS info hex string via MQTT.

  Backend: print_scheduler.py (+316 lines), bambu_mqtt.py, printer_manager,
  schemas, settings route. Frontend: PrintersPage drying presets prop,
  SettingsPage drying config UI, i18n (7 locales). Tests: 27 new tests in
  test_scheduler_auto_drying.py covering conservative params, presets,
  state sync, stop logic, minimum drying time, and auto-stop regressions.
2026-03-14 14:21:36 +01:00
maziggy f21e502b8f Add remote AMS drying controls (#292)
Start, monitor, and stop drying sessions for AMS 2 Pro (n3f) and
  AMS-HT (n3s) directly from the Printers page. Flame icon in AMS card
  header opens a popover with filament-based temperature/duration presets
  from BambuStudio. Live countdown status bar shows time remaining.

  Backend: cache module_type from MQTT get_version, expose dry_time and
  module_type in both WebSocket and REST paths, add supports_drying()
  with firmware gating, add server-side guard on start_drying endpoint.

  Frontend: drying button, popover with filament select + temp/duration
  sliders, status bar, start/stop mutations. i18n for all 7 locales.

  Supported: X1/X1C (fw 01.09+), P1P/P1S (fw 01.08+), H2D (fw 01.02.30+),
  H2D Pro, X1E. Not supported: P2S, A1, A1 Mini, H2S, H2C.
2026-03-12 16:46:10 +01:00
maziggy 26a3b2172d Fix ethernet badge shown on WiFi-only printers (#585)
home_flag bit 18 is set on all printers regardless of hardware,
    causing the ethernet badge to appear on WiFi-only models (A1, P1P,
    etc.). The previous fix removed the feature entirely, so ethernet
    printers lost their badge too.

    Now only trusts bit 18 on models with an ethernet port (X1C, X1E,
    P1S, P2S, H2D, H2D Pro, H2C, H2S). WiFi-only models always show
    the WiFi signal badge.
2026-03-11 12:56:23 +01:00
maziggy 121b3d53df fix: remove incorrect ethernet badge on printer cards
home_flag bit 18 was incorrectly interpreted as "wired/ethernet
  connection", causing the ethernet badge to always show — even on
  printers without an ethernet port (e.g. A1, P1S). This hid the
  WiFi signal indicator entirely.

  Removed the wired_network field and ethernet badge UI. The WiFi
  signal badge now shows correctly whenever the printer reports
  signal strength.
2026-03-09 12:16:22 +01:00
Thomas RambachandMartinNYHC 7ba67012f6 Feature AMS Info Card (#570)
* AMS Labels addition to PrintersPage

* Added database reinitialization for schema migrations on database restore

* Bug fixes and AMS Label persistence updates

* Update database.py to resolve PR conflicts

* PR Comment Resolution

* Resolve conflicts in database.py for PR#570

* Updates to address PR#570 additional comments

* Optimize visibility handling for popup component

* Improve serial key handling in printers.py

Refactor serial key assignment to handle empty AMS serial gracefully.

* Implement error handling in serial number mapping

Add error handling for serial number mapping.

* Add migration to drop old ams_labels table

---------

Co-authored-by: MartinNYHC <mz@v8w.de>
2026-03-05 08:36:39 +01:00
maziggy 6388b0df9b Show ethernet indicator instead of WiFi signal for wired printers (#585)
Parse home_flag bit 18 (0x00040000) from MQTT to detect ethernet
  connections. When set, the printer card shows a green "Ethernet"
  badge with a cable icon instead of WiFi signal strength in dBm.
  The printer info modal also displays "Ethernet" instead of WiFi
  signal details.
2026-03-04 09:44:08 +01:00
maziggy 0e87c377e6 Add developer LAN mode detection and warning banner
Parse the MQTT "fun" field bit 0x20000000 to detect whether connected
printers have Developer LAN Mode enabled. Show a persistent orange
warning banner when any printer lacks it, since newer firmware silently
rejects MQTT write commands without developer mode.

- Parse fun field into developer_mode on PrinterState
- Add /printers/developer-mode-warnings lightweight polling endpoint
- Include developer_mode in printer status API and support bundle
- Orange banner with affected printer names and wiki link
- Translations for all 6 locales (en, de, fr, it, ja, pt-BR)
- 7 backend + 4 frontend tests
2026-02-21 12:06:16 +01:00
maziggy a0abeba394 fix(queue): persist clear plate state across page refresh (#410)
After clicking "Clear Plate & Start Next", refreshing the page showed
the button again because the frontend determined the state purely from
the printer's FINISH/FAILED status. The backend already tracked a
plate_cleared flag in memory but never exposed it to the frontend.

- Add plate_cleared field to PrinterStatus schema and API response
- Pass plateCleared prop to PrinterQueueWidget
- Skip clear plate UI when plate is already acknowledged
- Add 2 tests for plateCleared=true behavior
2026-02-17 12:14:47 +01:00
maziggy a37dfaf7fb feat: dual external spool support, AMS slot model filtering & pre-population
Backend:
- Add dual external spool support for H2D (vt_tray as list: Ext-L/Ext-R)
- Add cloud filament ID map endpoint (/cloud/filament-id-map)
- Fix RFID spool data erased by periodic AMS updates (skip tag matcher
  for RFID-tagged trays)
- Fix AMS slot config overwrites RFID spool state
- Fix K-profile selection corrupts existing profiles on X1C/P1S
- Resolve K-profiles filament name via cloud filament ID map
- Update print scheduler and usage tracker for dual external spools

Frontend:
- Add printer model filtering to ConfigureAmsSlotModal (cloud/local/builtin
  presets filtered by @BBL model suffix and compatible_printers)
- Add pre-population for configured slots (preset, color, K-profile)
- Add K-Profiles view with accurate filament name resolution
- Internationalize all ConfigureAmsSlotModal strings (en/de/fr/it/ja — 21 keys)
- Add 5 new ConfigureAmsSlotModal tests (model filtering, pre-selection,
  color pre-population, i18n)
- Update PrintersPage for dual external spool rendering

Docs:
- Update CHANGELOG, README, website features, and wiki AMS docs
2026-02-15 08:04:01 +01:00
maziggy 30b8887e79 H2C nozzle rack: show all 6 nozzles, translate types, add flow & filament (#300)
- Show all 6 nozzles including mounted: backend includes all nozzle_info
  entries (removes id >= 2 filter), frontend filters to non-empty
- Translate nozzle type codes to full names: HS→Hardened Steel, 00/01/05
  mapped to Stainless Steel/Hardened Steel/Tungsten Carbide
- Add flow type to hover card: HH→High Flow, HS→Standard
- Show filament material type in hover card (PLA, PETG etc.) from MQTT
  tray_type/filament_type field
- Add filament_type to NozzleRackSlot schema (backend + frontend)
- Add translations (en, de, ja, it): nozzleTungstenCarbide, nozzleFlow,
  nozzleHighFlow, nozzleStandardFlow
2026-02-10 11:34:12 +01:00
maziggy 6661bbf866 Add full nozzle rack metrics and per-slot hover cards for H2C printers
Capture 4 additional fields from MQTT nozzle data (max_temp, serial_number,
filament_color, filament_id) and surface them through REST/WebSocket APIs.
Add per-slot hover popover to the NozzleRackCard showing all metrics, filament
color backgrounds on slots, and i18n labels in all 4 locales.
2026-02-09 15:10:49 +01:00
maziggy 48174d3a08 Add H2C nozzle rack support — store and display 6-position tool-changer dock
The H2C printer has a tool-changer with a 6-nozzle rack, but
device.nozzle.info entries beyond index 1 were being dropped due to a
hardcoded 2-nozzle limit. This adds full nozzle rack storage, API
exposure, and a frontend card showing all dock positions.
2026-02-09 09:21:50 +01:00
maziggy 8944943981 Allow hostnames for printers in addition to IPv4 addresses (fixes #290)
Users with local DNS can now add printers using hostnames like
printer.local or my-printer.home.lan. Updated backend schema
validation, database column width, frontend form patterns/placeholders,
and i18n labels across all locales. Added integration tests for
hostname and FQDN creation plus invalid hostname rejection.
2026-02-07 16:16:43 +01:00
maziggy 9d6164ab1c Add USB camera support (V4L2)
- Add USB camera type to external camera service
- Auto-detect available V4L2 devices on Linux
- New API endpoint: GET /api/v1/printers/usb-cameras
- Use ffmpeg for USB camera capture and streaming
- Add "USB Camera (V4L2)" option in Settings UI
- Debounce camera URL input to avoid saving on every keystroke

Closes #143
2026-01-27 06:40:14 +01:00
maziggy 888891fdc6 Add build plate empty detection feature
Automatically detect if objects are on the build plate before printing
and pause the print immediately if detected.

Features:
- Per-printer toggle to enable/disable plate detection
- Multi-reference calibration: store up to 5 reference images per printer
  for different plate types (textured, smooth, high-temp, etc.)
- Automatic print pause when objects detected at print start
- Push notification and WebSocket alert when print is paused
- ROI (Region of Interest) calibration UI with sliders to adjust
  detection area
- Reference management: view thumbnails, add labels, delete references
- Works with both built-in and external cameras
- Uses buffered camera frames when stream is active (no blocking)
- Split button UI: main button opens modal, chevron toggles on/off
- Green visual indicator when plate detection is enabled
- Included in backup/restore
2026-01-26 13:04:29 +01:00
maziggy 691fb133b7 Add external network camera support for printers
Add support for external network cameras (MJPEG, RTSP, HTTP snapshot)
that replace a printer's built-in camera when configured.

Features:
- Live streaming on printers page (replaces built-in camera)
- Finish photo capture from external camera on print complete
- Layer-based timelapse: captures frame on each layer change,
  stitches to MP4 video on print completion

Backend changes:
- Add external_camera_url, external_camera_type, external_camera_enabled
  fields to Printer model with database migration
- New external_camera.py service: MJPEG/RTSP/snapshot frame capture,
  connection testing, MJPEG stream generation
- New layer_timelapse.py service: TimelapseSession management,
  layer-by-layer frame capture, ffmpeg video stitching
- Add on_layer_change callback to MQTT client and printer manager
- Update camera routes with external camera streaming and tracking
- Update print lifecycle hooks for timelapse start/stitch/cancel
- Add external camera fields to backup/restore
- Rate limiting for external camera streams (prevents browser freeze)

Frontend changes:
- Add external camera configuration UI in Settings > Camera
- Per-printer enable toggle, URL input, type selector, test button
- Toast notification on save

Closes #143
2026-01-24 09:58:45 +01:00
maziggy 6fb71de6a2 Add firmware update helper for LAN-only printers
Enables checking and uploading firmware updates for printers operating
  in LAN-only mode without Bambu Cloud connectivity.

  Features:
  - Automatic firmware version checking against Bambu Lab servers
  - Orange "Update" badge on printer cards when updates available
  - Firmware update modal with version info and release notes
  - One-click firmware upload to printer SD card via FTP
  - Real-time upload progress (actual bytes transferred)
  - Step-by-step instructions for triggering update from printer
  - Local firmware caching for faster re-uploads
  - Supports all Bambu Lab printer models

  New files:
  - backend/app/services/firmware_check.py - Version checking service
  - backend/app/services/firmware_update.py - Upload orchestration
  - backend/app/api/routes/firmware.py - REST API endpoints

  Also includes:
  - FTP upload progress callback support
  - 10-minute upload timeout protection
  - Firmware cache directory in .gitignore
2026-01-04 18:41:24 +01:00
maziggy 94c961dbaf Add real-time fan status monitoring to printer cards
- Controls section: New section before Filaments with fan status and printer controls
  - Part cooling fan (Fan icon, cyan)
  - Auxiliary fan (Wind icon, blue)
  - Chamber fan (AirVent icon, green)
  - Stop/Pause/Resume buttons moved from Temperature section
- Real-time updates: Fan speeds now broadcast via WebSocket
- Backend: Parse MQTT fan data (cooling_fan_speed, big_fan1_speed, big_fan2_speed)
  - Convert 0-15 scale to 0-100%
- Always-visible badges with dynamic coloring based on fan state
- Removed horizontal dividers before Controls and Filaments sections
2026-01-02 16:05:20 +01:00
maziggy 2dcd1a2ef2 - Enhanced skip objects feature with visual improvements and better UX
- Skip Objects Modal:
    - Object ID markers overlaid on preview image (grid layout)
    - Large prominent ID badges to match printer display
    - Info banner explaining to match IDs with printer screen
    - Layer warning when skip unavailable (layer <= 1)
    - Red badge on button showing skipped count
    - Preview image now shown when paused (not just running)
    - Close with ESC key or click outside modal
    - Full light/dark theme support

  - Backend:
    - Extract object positions from 3MF (include_positions=True)
    - API returns x/y coordinates for objects (when available)
    - Parse s_obj from printer MQTT for skipped state persistence
    - Cover URL available in PAUSE/PAUSED states

  - Tests:
    - Added test for objects with position data
2026-01-01 18:01:41 +01:00
maziggy ccdb084f23 - Refactored printer card's AMS section for better experience 2026-01-01 12:08:55 +01:00