Swipe down from the top of the SpoolBuddy display to open a quick-access
menu for toggling printer smart plugs and managing the device (restart
daemon, restart browser, reboot, shutdown). All destructive actions
require confirmation.
Backend: new POST /spoolbuddy/devices/{id}/system/command endpoint
queuing reboot/shutdown/restart_daemon/restart_browser commands.
Daemon: handles commands via subprocess (sudo reboot, systemctl restart).
Frontend: SpoolBuddyQuickMenu component, swipe-down gesture detection,
i18n keys for all 7 locales.
Users can authenticate against an LDAP/AD server with configurable
server URL, bind DN, search base, and user filter. Supports StartTLS
and LDAPS — plaintext is not allowed. Both Active Directory (memberOf)
and POSIX groups (memberUid) are mapped to BamBuddy groups on each
login. Auto-provisioning creates local accounts on first LDAP login.
Local admin accounts remain as fallback when LDAP is unreachable.
Password management is disabled for LDAP users.
When auto_archive was disabled but the print was dispatched by BamBuddy
(queue/reprint), on_print_start discarded the expected print entry and
returned early. The archive was never promoted to _active_prints, so at
completion archive_id and ams_mapping were both None — all tracking paths
failed silently. Now detects expected prints before the auto-archive
early-return and falls through to the normal promotion path. Also injects
the stored ams_mapping into the usage tracker session for printers where
MQTT request topic subscription fails (P1S, A1).
When multiple smart plugs were assigned to the same printer, only the
first plug's automation triggered. All automation paths (print start
auto-on, print complete auto-off, queue auto-off, scheduler power-on)
now iterate every plug linked to the printer. Also fix queue auto-off
hardcoded to Tasmota instead of using the correct service for the plug
type.
Queue status update (printing → completed) failed silently when SQLite
was locked by another writer, leaving ghost jobs permanently stuck in
printing status. Add run_with_retry() for SQLite lock retries and split
runtime tracker into per-printer commits to reduce lock hold time.
The dev mode probe (ams_filament_setting to ext slot) fired on every
auto-reconnect, which destabilized some firmware MQTT brokers (A1/P1)
causing a reconnect-probe-disconnect feedback loop. Now caches the
probe result across reconnects and only probes once on first connect,
with a 5s delay to let the session stabilize.
When auto-archive was off, archive_id was None at print completion so
the entire 3MF tracking path was skipped. AMS remain% fallback also
failed on printers reporting remain=-1. Now searches library files and
previous archives by filename to locate the 3MF without an archive,
and captures the AMS slot-to-tray mapping at print start so it's
available at completion regardless of archive state.
Per-model start/end G-code snippets configurable in Settings (Workflow
tab). Queue items get "Inject G-code" toggle — scheduler injects
snippets into a temp 3MF copy before FTP upload. Supports Farmloop,
SwapMod, AutoClear, Printflow 3D and similar bed-clearing systems.
Original files are never modified.
External folder scan now mirrors disk subfolder structure into the folder
tree instead of flattening all files into root. Hidden directories are
filtered, orphaned subfolders are cleaned up on rescan. Fixes#890.
File manager delete endpoints (folder, file, bulk) now commit before
returning the response — previously relied on post-response auto-commit,
causing a race where the frontend refetch arrived before the commit.
Add timeout and retry to the developer mode probe. After a keep-alive
timeout, paho auto-reconnects but the session can be half-broken: the
printer sends status but ignores commands. The probe had no recovery —
one unanswered probe permanently blocked retries. Now times out after
10s with one retry; two consecutive failures force-close the socket for
a clean reconnect.
New SJF toggle badge on the queue page. When enabled, the scheduler
picks shorter print jobs before longer ones instead of FIFO. A
starvation guard flags jobs that get skipped once, moving them to
the front on the next cycle so long jobs can't be postponed indefinitely.
- Add print_time_seconds and been_jumped columns to PrintQueueItem
- Cache print duration from 3MF metadata at queue item creation
- SJF query: printer_id, target_model, been_jumped DESC, print_time_seconds ASC, position
- Mark jumped items in-memory after each print start
- Toggle badge on queue page header with live state indicator
- Frontend auto-sorts to match scheduler order when SJF enabled
- Settings schema, boolean parsing, and migration (SQLite + PostgreSQL)
- i18n badge keys for all 7 locales
- 10 integration tests for SJF ordering and starvation logic
- Wiki, website, README, and changelog updated
Move H2S from the drying-unsupported blocklist to the firmware-gated
list, requiring minimum firmware 01.02.00.00 (released end of March
2026). Both remote AMS drying and queue auto-drying now work on H2S.
Bambuddy can now use an external PostgreSQL database via the
DATABASE_URL environment variable. SQLite remains the default.
Dialect-aware helpers handle upserts, PRAGMAs, FTS (FTS5 vs
tsvector+GIN), backup/restore, and health checks. All migration
blocks use savepoints to prevent Postgres transaction poisoning.
Backups are always portable SQLite format regardless of backend.
Cross-database restore imports SQLite backups into PostgreSQL
with automatic boolean/datetime conversion, NOT NULL default
filling, and FK constraint handling.
REST/Webhook smart plugs can now fetch power and energy data from
individual URLs instead of requiring all values in a single status
response. Each value falls back to the shared Status URL when no
separate URL is set, preserving backward compatibility. Added power
and energy multipliers for unit conversion (e.g. 0.001 for Wh→kWh).
Race condition in _update_state: dev mode probe released GIL via MQTT
publish between raw_data overwrite and vt_tray list restoration, letting
the event loop iterate over raw dict keys (strings) instead of spool
dicts. Affects A1, P1, and X1Plus firmware that don't send the fun field.
Fix: normalize vt_tray dict→list before raw_data assignment, restore
preserved fields before any GIL-releasing work, add defensive guard in
printer_state_to_dict.
The test conftest.py model import list was out of sync with database.py,
missing slot_preset, project_bom, spool_k_profile, and spoolbuddy_device.
Base.metadata.create_all() never created those tables in the test DB.
GitHub backup can now optionally include spool inventory (with usage
history) and print archive metadata as JSON. Both toggles are off by
default. No binary files (gcode/3MF) are included.
Single-nozzle printers (X1C, P1S, A1) report tray_now=254 for external
spool, but BambuStudio sends ams_id=255 (VIRTUAL_TRAY_MAIN_ID) in the
print command's ams_mapping2 field. Bambuddy was passing 254 as-is,
causing firmware to target AMS tray 0 instead of external spool —
resulting in 07FF_8012 "Failed to get AMS mapping table" or prints stuck
at heatbed heating when an AMS is connected but empty.
Map external spool to ams_id=255 for all non-H2D printers. H2D
dual-nozzle printers retain 254 (deputy) / 255 (main) distinction.
When multiple AMS spools match the same type/color criteria, an optional
setting now prefers the spool with the lowest remaining filament. This
helps consume partial spools before starting new ones. Sorting applies
to all matching paths: queue scheduler, print modal, and multi-printer
mapping. Unknown remain values (-1) sort to end.
Admins can now filter the Statistics page by user via a new
stats:filter_by_user permission. A user dropdown appears in the stats
header showing all users plus "No User (System)" for prints without
attribution. The filter applies to all stats widgets, failure analysis,
and CSV/Excel exports. Backend validates the permission on all 4 stats
endpoints, returning 403 if the filter is used without authorization.
Stagger option now available when printing directly to multiple printers,
not just in queue mode. Prints are automatically queued with staggered
start times using group size/interval from Settings. New "Require
plate-clear confirmation" setting lets farm users disable per-printer
plate confirmations so queued prints start automatically on finished
printers.
Also fixes settings API type parsing for require_plate_clear (boolean),
stagger_group_size and stagger_interval_minutes (integer) — without this,
saved values returned as strings would cause the settings toggle to
always show enabled and trigger a permanent save loop.
Printers with no AMS hardware (P1S/P1P with only external spool)
rejected print commands with "Failed to get AMS mapping table"
because use_ams was always sent as true. Now auto-sets use_ams=false
when all filament slots map to external spools or are unmapped.
H2D-series excluded since they use use_ams for nozzle routing.
When adding a print to the queue for multiple printers, users can now
enable "Stagger printer starts" to avoid power spikes from simultaneous
bed heating. Configurable group size and interval — first group starts
immediately (ASAP) or at scheduled time, subsequent groups get offset
scheduled_time values. No backend queue/scheduler changes — leverages
existing scheduled_time field.
Also adds a dedicated Queue tab in Settings (stagger defaults + auto-
drying moved from Filament tab), i18n keys for all 7 locales, frontend
and backend tests.
Auto-off now has a "Keep Enabled" toggle that keeps it active between
prints instead of disabling after each use (one-shot). Useful for HA
accessories like BentoBox filters that should always power off after
prints. Default behavior (one-shot) is unchanged.
The stale connection fix (6ac375a) force-closed the socket to trigger
paho reconnect, but paho's disconnect callback redundantly broadcast
state changes, causing rapid connected/disconnected cycling in the UI.
Now sets a flag before the force-close so _on_disconnect skips the
redundant broadcast. Also relaxed keepalive from 15s to 30s — the
aggressive interval caused spurious disconnects on transient hiccups.
Moved _disconnection_event.set() to the top of _on_disconnect so no
early-return filter can prevent it from unblocking disconnect() callers.
Removed leftover debug payload dump.
The daemon now collects CPU temp, core count, load average, memory/disk
usage, OS info, and system uptime every heartbeat using stdlib-only reads
from /proc and /sys. Stats are sent as a JSON blob in the heartbeat
payload, stored in a new system_stats TEXT column, and displayed in a
new "System" tab in SpoolBuddy Settings with color-coded usage bars.
Assigning or unassigning a spool now broadcasts a spool_assignment_changed
event to all connected WebSocket clients. The frontend handles this event
by invalidating the spool-assignments and slotPresets caches, so other
open tabs update automatically without a page reload.
BambuStudio converts virtual tray IDs (254/255) to -1 in the flat
ams_mapping and relies on ams_mapping2 for external spool routing.
Bambuddy was passing raw 254/255 in the flat array, which H2D firmware
rejects with "Failed to get AMS mapping table".
- Convert external tray IDs to -1 in flat ams_mapping (match BambuStudio)
- Fix ams_mapping2 for external trays: each virtual tray is its own AMS
unit with slot_id 0, not a shared unit differentiated by slot
- Fix main/deputy nozzle ID comment (255=main, 254=deputy per BambuStudio)
- Add 8 unit tests for start_print() mapping construction
External folder scan generated thumbnails for 3mf/stl/gcode files but
skipped image files. Added IMAGE_EXTENSIONS check with
create_image_thumbnail() to the scan loop.
Some printers (e.g. H2D) only send {id, state} in incremental MQTT
tray updates — no tray_type, tray_color, or other fields. When
filament is unloaded (state changes from 11 to 10), the old tray
data persisted indefinitely because the merge logic only updates
fields present in the incoming message.
Backend:
- Detect tray state != 11 without tray_type in incremental updates
and clear stale tray data (bambu_mqtt.py)
- Expose tray `state` field via REST API and WebSocket broadcasts
(printer.py schema, printers.py route, printer_manager.py)
- Include AMS tray content in WebSocket dedup key so load/unload
transitions trigger broadcasts (main.py)
Frontend:
- Add `state` to AMSTray interface (client.ts)
- Show configure/assign buttons for state=10 (spool present, not
loaded) but hide for state=9 (truly empty) on AMS/HT slots
- Hide fill level bar on empty slots
Tests:
- 5 new tests covering state-based clearing, preservation, reload,
and idempotency
When a Bambu Lab spool is detected in the AMS but no tag match exists,
check for an untagged inventory spool with matching material/subtype/color
before creating a new entry. Links the RFID tag to the existing spool
(data_origin="rfid_linked") to prevent duplicate inventory entries.
Host directories (NAS, USB, network shares) can now be mounted
into the File Manager without copying files. Files are indexed
into the database on scan but read directly from their original
location. Supports read-only mode, hidden file filtering, and
automatic thumbnail extraction for 3MF/STL/gcode.
- POST /library/folders/external — create with path validation
- POST /library/folders/{id}/scan — discover/sync files
- Block uploads, moves, and deletes for read-only external folders
- Never delete actual files from external paths (DB-only removal)
- Purple folder icon + info bar with rescan button in UI
- i18n for all 7 languages
- 19 backend + 11 frontend tests
15 backend unit tests covering keypair management, branch detection,
SSH command execution (success/failure/timeout), and full update flow
with error handling. 4 new frontend tests for the Updates tab (version
display, buttons, SSH setup, update available state).
The daemon's self-update mechanism (git fetch/reset on its own code) was
fragile: .git permission errors, self-modifying code mid-run, hardcoded
main branch. Bambuddy now SSHes into the SpoolBuddy Pi and drives the
update remotely — matching its own branch, with step-by-step progress
via WebSocket. Install script updated with SSH access, sudoers entry,
and --ssh-pubkey flag for pairing.
BambuStudio connects to undocumented proprietary ports 2024-2026
on A1/P1S models during the print flow. The proxy wasn't forwarding
these ports, causing connection refused (RST) and triggering the
access code dialog instead of printing. MQTT and FTP worked fine —
port 2024 was the sole blocker.
Added transparent TCP pass-through proxies for ports 2024-2026,
following the same pattern as the existing FileTransfer (6000) and
RTSP (322) proxies. Silently ignored on models that don't use them.
When targeting a specific printer, the scheduler's power-on-wait loop
created new MQTT clients on each attempt. Each new client re-tried the
request topic subscription, which some brokers (e.g. A1) reject by
disconnecting. This caused a 170s thrash loop leaving the connection
fragile, so the eventual print command silently failed to reach the
printer.
Cache request topic support per serial number at the class level so
new client instances inherit the knowledge and skip the subscription.
When a printer shuts down it sends a final MQTT message with
tray_exist_bits=0 and power_on_flag=false. The tray_exist_bits
clearing code processed this all-zero value, wiping every AMS
slot's filament data. On reconnect, the auto-unlink check saw
empty tray data (no color, no type) and deleted all spool
assignments as "fingerprint mismatch".
Fix: skip tray_exist_bits slot clearing when power_on_flag is
false. Defaults to true when absent for backwards compatibility.
Adds 3 regression tests covering shutdown preservation, genuine
removal still working, and missing power_on_flag fallback.
Replace fixed 30-second debug log collection with an interactive
3-step flow: start logging, reproduce the issue, stop & submit.
Users now control timing instead of racing a countdown.
Backend: split _collect_debug_logs() into POST /start-logging and
POST /stop-logging endpoints; add debug_logs field to submit request.
Frontend: 3-step progress indicator with elapsed timer, pulsing
active state, and 5-minute auto-stop. Updated all 7 locale files.
Add a "Rotate spool during drying" checkbox to the manual drying popover
for AMS 2 Pro and AMS-HT units. The firmware-level rotate_tray field was
already sent (hardcoded to false) — this makes it user-configurable.
The checkbox defaults to unchecked and resets each time the popover opens.
Firmware silently disables rotation if filament is currently loaded.
When all matching printers were busy and a job was queued with ASAP
timing, the scheduler immediately fired a "Job Waiting for Filament"
notification even though the job was just waiting for a printer to
finish — no user action required.
Added _is_busy_only() check to skip the waiting notification when the
only reason is "Busy". Notifications still fire for actionable reasons
(missing filament, offline, wrong color). Also renamed the default
notification template title to "Queue Job Waiting" and updated
descriptions across all 7 locales.
The closed-source bambu_networking DLL validates TLS connection parameters
and rejects connections where the certificate doesn't match the printer's
real BBL CA certificate. The TLS-terminating proxy presented Bambuddy's
own certificate, causing X1C/X1 prints to silently fail after verify_job.
Switch to transparent TCP proxying for FTP, FileTransfer, Camera, and FTP
data — only MQTT remains TLS-terminated (required for IP rewriting). The
slicer now gets end-to-end TLS directly with the printer's real certificate.
Changes:
- SlicerProxyManager uses TCPProxy for FTP (990), FileTransfer (6000),
Camera (322), and pre-listens on FTP data ports (50000-50100)
- Only MQTT (8883) uses TLSProxy for IP rewriting
- Remove debug logging from MQTT and FTP proxy code
- Fix install.sh missing AmbientCapabilities=CAP_NET_BIND_SERVICE
- Update module docstring, migration docs, README proxy description
- Add tests verifying transparent proxy architecture