mirror of
https://github.com/maziggy/bambuddy.git
synced 2026-10-22 03:49:18 +02:00
fix: reduce MQTT log noise at INFO level (#365)
Downgrade 58 diagnostic logger.info calls to logger.debug in bambu_mqtt.py — payload dumps, detector state changes, field discovery, H2D disambiguation, and periodic status updates no longer flood logs at the default INFO level. User-initiated actions (print, stop, calibration, AMS load/unload) remain at INFO. Also suppress paho-mqtt library INFO messages in production mode.
This commit is contained in:
@@ -106,10 +106,12 @@ def _apply_log_level(debug: bool):
|
||||
logging.getLogger("sqlalchemy.engine").setLevel(logging.INFO)
|
||||
logging.getLogger("httpcore").setLevel(logging.DEBUG)
|
||||
logging.getLogger("httpx").setLevel(logging.DEBUG)
|
||||
logging.getLogger("paho.mqtt").setLevel(logging.DEBUG)
|
||||
else:
|
||||
logging.getLogger("sqlalchemy.engine").setLevel(logging.WARNING)
|
||||
logging.getLogger("httpcore").setLevel(logging.WARNING)
|
||||
logging.getLogger("httpx").setLevel(logging.WARNING)
|
||||
logging.getLogger("paho.mqtt").setLevel(logging.WARNING)
|
||||
|
||||
logger.info("Log level changed to %s", "DEBUG" if debug else "INFO")
|
||||
|
||||
|
||||
@@ -165,6 +165,7 @@ if not app_settings.debug:
|
||||
logging.getLogger("sqlalchemy.engine").setLevel(logging.WARNING)
|
||||
logging.getLogger("httpcore").setLevel(logging.WARNING)
|
||||
logging.getLogger("httpx").setLevel(logging.WARNING)
|
||||
logging.getLogger("paho.mqtt").setLevel(logging.WARNING)
|
||||
|
||||
logging.info("Bambuddy starting - debug=%s, log_level=%s", app_settings.debug, log_level_str)
|
||||
from fastapi.responses import FileResponse
|
||||
|
||||
@@ -372,7 +372,7 @@ class BambuMQTTClient:
|
||||
# TEMP: Dump full payload once to find extruder state field
|
||||
if not hasattr(self, "_payload_dumped"):
|
||||
self._payload_dumped = True
|
||||
logger.info("[%s] FULL MQTT PAYLOAD DUMP:\n%s", self.serial_number, json.dumps(payload, indent=2))
|
||||
logger.debug("[%s] FULL MQTT PAYLOAD DUMP:\n%s", self.serial_number, json.dumps(payload, indent=2))
|
||||
# Log message if logging is enabled
|
||||
if self._logging_enabled:
|
||||
self._message_log.append(
|
||||
@@ -400,7 +400,7 @@ class BambuMQTTClient:
|
||||
# Handle xcam data (camera settings and AI detection) at top level
|
||||
if "xcam" in payload:
|
||||
xcam_data = payload["xcam"]
|
||||
logger.info("[%s] Received xcam data at top level: %s", self.serial_number, xcam_data)
|
||||
logger.debug("[%s] Received xcam data at top level: %s", self.serial_number, xcam_data)
|
||||
self._parse_xcam_data(xcam_data)
|
||||
# Fire state change callback for top-level xcam (not nested in "print")
|
||||
if "print" not in payload and self.on_state_change:
|
||||
@@ -409,7 +409,7 @@ class BambuMQTTClient:
|
||||
# Handle system responses (accessories info, etc.)
|
||||
if "system" in payload:
|
||||
system_data = payload["system"]
|
||||
logger.info("[%s] Received system data: %s", self.serial_number, system_data)
|
||||
logger.debug("[%s] Received system data: %s", self.serial_number, system_data)
|
||||
self._handle_system_response(system_data)
|
||||
|
||||
# Handle info responses (firmware version info from get_version command)
|
||||
@@ -434,12 +434,12 @@ class BambuMQTTClient:
|
||||
|
||||
# Check if xcam is nested inside print data
|
||||
if "xcam" in print_data:
|
||||
logger.info("[%s] Found xcam inside print data: %s", self.serial_number, print_data["xcam"])
|
||||
logger.debug("[%s] Found xcam inside print data: %s", self.serial_number, print_data["xcam"])
|
||||
self._parse_xcam_data(print_data["xcam"])
|
||||
|
||||
# Log when we see gcode_state changes
|
||||
if "gcode_state" in print_data:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] Received gcode_state: {print_data.get('gcode_state')}, "
|
||||
f"gcode_file: {print_data.get('gcode_file')}, subtask_name: {print_data.get('subtask_name')}"
|
||||
)
|
||||
@@ -508,7 +508,7 @@ class BambuMQTTClient:
|
||||
cmd = print_data.get("command")
|
||||
logger.debug("[%s] Received command response: %s", self.serial_number, cmd)
|
||||
if cmd in ("extrusion_cali_sel", "extrusion_cali_set", "extrusion_cali_del", "ams_filament_setting"):
|
||||
logger.info("[%s] %s response: %s", self.serial_number, cmd, print_data)
|
||||
logger.debug("[%s] %s response: %s", self.serial_number, cmd, print_data)
|
||||
if "command" in print_data and print_data.get("command") == "extrusion_cali_get":
|
||||
self._handle_kprofile_response(print_data)
|
||||
|
||||
@@ -528,7 +528,7 @@ class BambuMQTTClient:
|
||||
# Log response for debugging - but DON'T use it to update nozzle data
|
||||
# because it returns stale values (e.g., 'stainless_steel' when the
|
||||
# actual nozzle is 'HH01' hardened steel high-flow)
|
||||
logger.info("[%s] Accessories response (not used for nozzle data): %s", self.serial_number, data)
|
||||
logger.debug("[%s] Accessories response (not used for nozzle data): %s", self.serial_number, data)
|
||||
|
||||
def _handle_version_info(self, data: dict):
|
||||
"""Handle version info response from get_version command.
|
||||
@@ -624,7 +624,7 @@ class BambuMQTTClient:
|
||||
if should_accept_value("spaghetti_detector", cfg_spaghetti):
|
||||
old_value = self.state.print_options.spaghetti_detector
|
||||
if cfg_spaghetti != old_value:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] spaghetti_detector changed (from cfg): {old_value} -> {cfg_spaghetti}"
|
||||
)
|
||||
self.state.print_options.spaghetti_detector = cfg_spaghetti
|
||||
@@ -632,7 +632,7 @@ class BambuMQTTClient:
|
||||
# Check hold timer for sensitivity before accepting
|
||||
if "halt_print_sensitivity" not in self._xcam_hold_start:
|
||||
if cfg_sensitivity != self.state.print_options.halt_print_sensitivity:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] Sensitivity changed (from cfg): "
|
||||
f"{self.state.print_options.halt_print_sensitivity} -> {cfg_sensitivity}"
|
||||
)
|
||||
@@ -648,7 +648,7 @@ class BambuMQTTClient:
|
||||
else:
|
||||
# Hold expired - accept from cfg
|
||||
if cfg_sensitivity != self.state.print_options.halt_print_sensitivity:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] Sensitivity synced (from cfg after hold): "
|
||||
f"{self.state.print_options.halt_print_sensitivity} -> {cfg_sensitivity}"
|
||||
)
|
||||
@@ -659,14 +659,14 @@ class BambuMQTTClient:
|
||||
cfg_pileup, cfg_pileup_sens = decode_detector(8)
|
||||
if should_accept_value("pileup_detector", cfg_pileup):
|
||||
if cfg_pileup != self.state.print_options.pileup_detector:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] pileup_detector changed (from cfg): {self.state.print_options.pileup_detector} -> {cfg_pileup}"
|
||||
)
|
||||
self.state.print_options.pileup_detector = cfg_pileup
|
||||
# Pileup sensitivity with hold timer
|
||||
if "pileup_sensitivity" not in self._xcam_hold_start:
|
||||
if cfg_pileup_sens != self.state.print_options.pileup_sensitivity:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] pileup_sensitivity changed (from cfg): {self.state.print_options.pileup_sensitivity} -> {cfg_pileup_sens}"
|
||||
)
|
||||
self.state.print_options.pileup_sensitivity = cfg_pileup_sens
|
||||
@@ -675,7 +675,7 @@ class BambuMQTTClient:
|
||||
elapsed = current_time - hold_start
|
||||
if elapsed > self._xcam_hold_time:
|
||||
if cfg_pileup_sens != self.state.print_options.pileup_sensitivity:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] pileup_sensitivity synced (from cfg after hold): {self.state.print_options.pileup_sensitivity} -> {cfg_pileup_sens}"
|
||||
)
|
||||
self.state.print_options.pileup_sensitivity = cfg_pileup_sens
|
||||
@@ -685,14 +685,14 @@ class BambuMQTTClient:
|
||||
cfg_clump, cfg_clump_sens = decode_detector(11)
|
||||
if should_accept_value("clump_detector", cfg_clump):
|
||||
if cfg_clump != self.state.print_options.nozzle_clumping_detector:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] nozzle_clumping_detector changed (from cfg): {self.state.print_options.nozzle_clumping_detector} -> {cfg_clump}"
|
||||
)
|
||||
self.state.print_options.nozzle_clumping_detector = cfg_clump
|
||||
# Clump sensitivity with hold timer
|
||||
if "nozzle_clumping_sensitivity" not in self._xcam_hold_start:
|
||||
if cfg_clump_sens != self.state.print_options.nozzle_clumping_sensitivity:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] nozzle_clumping_sensitivity changed (from cfg): {self.state.print_options.nozzle_clumping_sensitivity} -> {cfg_clump_sens}"
|
||||
)
|
||||
self.state.print_options.nozzle_clumping_sensitivity = cfg_clump_sens
|
||||
@@ -701,7 +701,7 @@ class BambuMQTTClient:
|
||||
elapsed = current_time - hold_start
|
||||
if elapsed > self._xcam_hold_time:
|
||||
if cfg_clump_sens != self.state.print_options.nozzle_clumping_sensitivity:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] nozzle_clumping_sensitivity synced (from cfg after hold): {self.state.print_options.nozzle_clumping_sensitivity} -> {cfg_clump_sens}"
|
||||
)
|
||||
self.state.print_options.nozzle_clumping_sensitivity = cfg_clump_sens
|
||||
@@ -711,14 +711,14 @@ class BambuMQTTClient:
|
||||
cfg_airprint, cfg_airprint_sens = decode_detector(14)
|
||||
if should_accept_value("airprint_detector", cfg_airprint):
|
||||
if cfg_airprint != self.state.print_options.airprint_detector:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] airprint_detector changed (from cfg): {self.state.print_options.airprint_detector} -> {cfg_airprint}"
|
||||
)
|
||||
self.state.print_options.airprint_detector = cfg_airprint
|
||||
# Airprint sensitivity with hold timer
|
||||
if "airprint_sensitivity" not in self._xcam_hold_start:
|
||||
if cfg_airprint_sens != self.state.print_options.airprint_sensitivity:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] airprint_sensitivity changed (from cfg): {self.state.print_options.airprint_sensitivity} -> {cfg_airprint_sens}"
|
||||
)
|
||||
self.state.print_options.airprint_sensitivity = cfg_airprint_sens
|
||||
@@ -727,7 +727,7 @@ class BambuMQTTClient:
|
||||
elapsed = current_time - hold_start
|
||||
if elapsed > self._xcam_hold_time:
|
||||
if cfg_airprint_sens != self.state.print_options.airprint_sensitivity:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] airprint_sensitivity synced (from cfg after hold): {self.state.print_options.airprint_sensitivity} -> {cfg_airprint_sens}"
|
||||
)
|
||||
self.state.print_options.airprint_sensitivity = cfg_airprint_sens
|
||||
@@ -833,7 +833,7 @@ class BambuMQTTClient:
|
||||
pending_slot = pending_target % 4
|
||||
if pending_slot == parsed_tray_now:
|
||||
# Slot matches our pending target - use the full global ID
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] H2D tray_now disambiguation: "
|
||||
f"slot {parsed_tray_now} matches pending_tray_target {pending_target} -> using global ID {pending_target}"
|
||||
)
|
||||
@@ -862,7 +862,7 @@ class BambuMQTTClient:
|
||||
snow_slot = snow_tray % 4 if snow_tray < 128 else -1
|
||||
if snow_slot == parsed_tray_now:
|
||||
if self.state.tray_now != snow_tray:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] H2D tray_now from snow: "
|
||||
f"extruder[{active_ext}] snow={snow_tray} (slot {snow_slot})"
|
||||
)
|
||||
@@ -890,7 +890,7 @@ class BambuMQTTClient:
|
||||
# Single AMS on this extruder - unambiguous
|
||||
active_ams_id = ams_on_extruder[0]
|
||||
global_tray_id = active_ams_id * 4 + parsed_tray_now
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] H2D tray_now fallback: "
|
||||
f"slot {parsed_tray_now} + single AMS {active_ams_id} -> global ID {global_tray_id}"
|
||||
)
|
||||
@@ -1036,7 +1036,7 @@ class BambuMQTTClient:
|
||||
slot_exists = (tray_exist_bits >> global_bit) & 1
|
||||
if not slot_exists and tray.get("tray_type"):
|
||||
# Slot is marked empty but has data - clear it
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] Clearing empty slot: AMS {ams_id} slot {tray_id} "
|
||||
f"(tray_exist_bits bit {global_bit} = 0)"
|
||||
)
|
||||
@@ -1098,7 +1098,7 @@ class BambuMQTTClient:
|
||||
if ams_hash != self._previous_ams_hash:
|
||||
self._previous_ams_hash = ams_hash
|
||||
if self.on_ams_change:
|
||||
logger.info("[%s] AMS data changed, triggering sync callback", self.serial_number)
|
||||
logger.debug("[%s] AMS data changed, triggering sync callback", self.serial_number)
|
||||
# Pass merged AMS data (not raw ams_list) — partial MQTT updates
|
||||
# may lack fields like 'remain' that the merged state preserves
|
||||
self.on_ams_change(merged_ams)
|
||||
@@ -1164,7 +1164,7 @@ class BambuMQTTClient:
|
||||
if not hasattr(self, "_fan_fields_logged"):
|
||||
fan_fields = {k: v for k, v in data.items() if "fan" in k.lower()}
|
||||
if fan_fields:
|
||||
logger.info("[%s] Fan fields in MQTT data: %s", self.serial_number, fan_fields)
|
||||
logger.debug("[%s] Fan fields in MQTT data: %s", self.serial_number, fan_fields)
|
||||
self._fan_fields_logged = True
|
||||
|
||||
if "cooling_fan_speed" in data:
|
||||
@@ -1181,7 +1181,7 @@ class BambuMQTTClient:
|
||||
new_stg = data["stg_cur"]
|
||||
# Always log ANY stg_cur change for debugging filament operations
|
||||
if new_stg != self.state.stg_cur:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] stg_cur changed: {self.state.stg_cur} -> {new_stg} ({get_stage_name(new_stg)})"
|
||||
)
|
||||
self.state.stg_cur = new_stg
|
||||
@@ -1193,15 +1193,15 @@ class BambuMQTTClient:
|
||||
# Log all fields for debugging dual-nozzle temperature discovery (only once)
|
||||
if "bed_temper" in data and not hasattr(self, "_temp_fields_logged"):
|
||||
temp_fields = {k: v for k, v in data.items() if "temp" in k.lower() or "chamber" in k.lower()}
|
||||
logger.info("[%s] Temperature-related fields: %s", self.serial_number, temp_fields)
|
||||
logger.debug("[%s] Temperature-related fields: %s", self.serial_number, temp_fields)
|
||||
# Log ALL keys in print data for H2D temperature discovery
|
||||
all_keys = sorted(data.keys())
|
||||
logger.info("[%s] ALL print data keys (%s): %s", self.serial_number, len(all_keys), all_keys)
|
||||
logger.debug("[%s] ALL print data keys (%s): %s", self.serial_number, len(all_keys), all_keys)
|
||||
self._temp_fields_logged = True
|
||||
|
||||
# Log vir_slot data (once) - this may contain per-extruder slot mapping for H2D
|
||||
if "vir_slot" in data and not hasattr(self, "_vir_slot_logged"):
|
||||
logger.info("[%s] vir_slot data: %s", self.serial_number, data["vir_slot"])
|
||||
logger.debug("[%s] vir_slot data: %s", self.serial_number, data["vir_slot"])
|
||||
self._vir_slot_logged = True
|
||||
|
||||
# Log nozzle hardware info fields (once)
|
||||
@@ -1211,7 +1211,7 @@ class BambuMQTTClient:
|
||||
if "nozzle" in k.lower() or "hw" in k.lower() or "extruder" in k.lower() or "upgrade" in k.lower()
|
||||
}
|
||||
if nozzle_fields and not hasattr(self, "_nozzle_fields_logged"):
|
||||
logger.info("[%s] Nozzle/hardware fields in MQTT data: %s", self.serial_number, nozzle_fields)
|
||||
logger.debug("[%s] Nozzle/hardware fields in MQTT data: %s", self.serial_number, nozzle_fields)
|
||||
self._nozzle_fields_logged = True
|
||||
# Parse active extruder from device.extruder.state bit 8
|
||||
# bit 8 = 0 → RIGHT extruder (active_extruder=0)
|
||||
@@ -1223,7 +1223,7 @@ class BambuMQTTClient:
|
||||
# Extract bit 8 for extruder position
|
||||
new_extruder = (state_val >> 8) & 0x1
|
||||
if new_extruder != self.state.active_extruder:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] ACTIVE EXTRUDER CHANGED (state bit 8): {self.state.active_extruder} -> {new_extruder} (0=right, 1=left) [state={state_val}]"
|
||||
)
|
||||
self.state.active_extruder = new_extruder
|
||||
@@ -1238,12 +1238,12 @@ class BambuMQTTClient:
|
||||
state_val = ext_data["state"]
|
||||
# Extract bits 12-14 (3 bits) for switch state
|
||||
switch_state = (state_val >> 12) & 0x7
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] device.extruder.state={state_val} (switch_state bits 12-14: {switch_state})"
|
||||
)
|
||||
# Log 'cur' field if present (might indicate current/active extruder)
|
||||
if "cur" in ext_data:
|
||||
logger.info("[%s] device.extruder.cur: %s", self.serial_number, ext_data["cur"])
|
||||
logger.debug("[%s] device.extruder.cur: %s", self.serial_number, ext_data["cur"])
|
||||
if "bed_temper" in data:
|
||||
temps["bed"] = float(data["bed_temper"])
|
||||
if "bed_target_temper" in data:
|
||||
@@ -1445,7 +1445,7 @@ class BambuMQTTClient:
|
||||
global_tray = ams_id * 4 + (slot & 0x03)
|
||||
old_val = self.state.h2d_extruder_snow.get(ext_id)
|
||||
if old_val != global_tray:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] H2D extruder[{ext_id}] snow: "
|
||||
f"raw={snow} (AMS {ams_id} slot {slot}) -> global tray {global_tray}"
|
||||
)
|
||||
@@ -1455,7 +1455,7 @@ class BambuMQTTClient:
|
||||
normalized = 254 if slot != 255 else 255
|
||||
old_val = self.state.h2d_extruder_snow.get(ext_id)
|
||||
if old_val != normalized:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] H2D extruder[{ext_id}] snow: "
|
||||
f"raw={snow} -> {'external' if normalized == 254 else 'unloaded'}"
|
||||
)
|
||||
@@ -1464,7 +1464,7 @@ class BambuMQTTClient:
|
||||
# External spool with hub mapping
|
||||
old_val = self.state.h2d_extruder_snow.get(ext_id)
|
||||
if old_val != ams_id:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] H2D extruder[{ext_id}] snow: "
|
||||
f"raw={snow} -> external hub {ams_id}"
|
||||
)
|
||||
@@ -1489,7 +1489,7 @@ class BambuMQTTClient:
|
||||
if "modeCur" in airduct_data:
|
||||
new_mode = airduct_data["modeCur"]
|
||||
if new_mode != self.state.airduct_mode:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] airduct_mode changed: {self.state.airduct_mode} -> {new_mode}"
|
||||
)
|
||||
self.state.airduct_mode = new_mode
|
||||
@@ -1597,7 +1597,7 @@ class BambuMQTTClient:
|
||||
# Parse HMS (Health Management System) errors
|
||||
if "hms" in data:
|
||||
hms_list = data["hms"]
|
||||
logger.info("[%s] HMS data received: %s", self.serial_number, hms_list)
|
||||
logger.debug("[%s] HMS data received: %s", self.serial_number, hms_list)
|
||||
self.state.hms_errors = []
|
||||
if isinstance(hms_list, list):
|
||||
for hms in hms_list:
|
||||
@@ -1641,7 +1641,7 @@ class BambuMQTTClient:
|
||||
# code stores the short format string for lookup
|
||||
short_code = f"{module:04X}_{error:04X}"
|
||||
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] print_error: {print_error} (0x{print_error:08x}) -> short_code={short_code}"
|
||||
)
|
||||
|
||||
@@ -1676,7 +1676,7 @@ class BambuMQTTClient:
|
||||
home_flag = home_flag & 0xFFFFFFFF
|
||||
store_to_sdcard = bool((home_flag >> 11) & 1)
|
||||
if store_to_sdcard != self.state.store_to_sdcard:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] store_to_sdcard changed: {self.state.store_to_sdcard} -> {store_to_sdcard}"
|
||||
)
|
||||
self.state.store_to_sdcard = store_to_sdcard
|
||||
@@ -1700,21 +1700,21 @@ class BambuMQTTClient:
|
||||
if "timelapse" in ipcam_data:
|
||||
timelapse_enabled = ipcam_data.get("timelapse") == "enable"
|
||||
if timelapse_enabled != self.state.timelapse:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] timelapse changed (from ipcam): {self.state.timelapse} -> {timelapse_enabled}"
|
||||
)
|
||||
self.state.timelapse = timelapse_enabled
|
||||
# Track if timelapse was ever active during this print
|
||||
if self.state.timelapse and self._was_running:
|
||||
self._timelapse_during_print = True
|
||||
logger.info("[%s] Timelapse detected during print (from ipcam)", self.serial_number)
|
||||
logger.debug("[%s] Timelapse detected during print (from ipcam)", self.serial_number)
|
||||
else:
|
||||
self.state.ipcam = ipcam_data is True
|
||||
|
||||
# Parse WiFi signal strength (dBm)
|
||||
if "wifi_signal" in data:
|
||||
wifi_signal = data["wifi_signal"]
|
||||
logger.info("[%s] wifi_signal received: %s", self.serial_number, wifi_signal)
|
||||
logger.debug("[%s] wifi_signal received: %s", self.serial_number, wifi_signal)
|
||||
if isinstance(wifi_signal, (int, float)):
|
||||
self.state.wifi_signal = int(wifi_signal)
|
||||
elif isinstance(wifi_signal, str):
|
||||
@@ -1728,7 +1728,9 @@ class BambuMQTTClient:
|
||||
if "spd_lvl" in data:
|
||||
new_speed = data["spd_lvl"]
|
||||
if new_speed != self.state.speed_level:
|
||||
logger.info("[%s] speed_level changed: %s -> %s", self.serial_number, self.state.speed_level, new_speed)
|
||||
logger.debug(
|
||||
"[%s] speed_level changed: %s -> %s", self.serial_number, self.state.speed_level, new_speed
|
||||
)
|
||||
self.state.speed_level = new_speed
|
||||
|
||||
# Parse skipped objects from printer status (s_obj field)
|
||||
@@ -1739,7 +1741,7 @@ class BambuMQTTClient:
|
||||
# Update skipped objects from printer's list
|
||||
new_skipped = [int(oid) for oid in s_obj if isinstance(oid, (int, str))]
|
||||
if new_skipped != self.state.skipped_objects:
|
||||
logger.info("[%s] skipped_objects updated from printer: %s", self.serial_number, new_skipped)
|
||||
logger.debug("[%s] skipped_objects updated from printer: %s", self.serial_number, new_skipped)
|
||||
self.state.skipped_objects = new_skipped
|
||||
|
||||
# Parse chamber light status from lights_report
|
||||
@@ -1751,7 +1753,7 @@ class BambuMQTTClient:
|
||||
if isinstance(light, dict) and light.get("node") == "chamber_light":
|
||||
new_light_state = light.get("mode") == "on"
|
||||
if new_light_state != self.state.chamber_light:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
f"[{self.serial_number}] chamber_light changed: {self.state.chamber_light} -> {new_light_state}"
|
||||
)
|
||||
self.state.chamber_light = new_light_state
|
||||
@@ -1816,7 +1818,7 @@ class BambuMQTTClient:
|
||||
)
|
||||
if not hasattr(self, "_nozzle_rack_logged") and nozzle_info:
|
||||
self._nozzle_rack_logged = True
|
||||
logger.info(
|
||||
logger.debug(
|
||||
"[%s] Nozzle info: %d entries, IDs: %s",
|
||||
self.serial_number,
|
||||
len(nozzle_info),
|
||||
@@ -1868,11 +1870,11 @@ class BambuMQTTClient:
|
||||
# Track RUNNING state for more robust completion detection
|
||||
if self.state.state == "RUNNING" and current_file:
|
||||
if not self._was_running:
|
||||
logger.info("[%s] Now tracking RUNNING state for %s", self.serial_number, current_file)
|
||||
logger.debug("[%s] Now tracking RUNNING state for %s", self.serial_number, current_file)
|
||||
# Check if timelapse was enabled in the same message (xcam parsed before this)
|
||||
if self.state.timelapse:
|
||||
self._timelapse_during_print = True
|
||||
logger.info("[%s] Timelapse detected when entering RUNNING state", self.serial_number)
|
||||
logger.debug("[%s] Timelapse detected when entering RUNNING state", self.serial_number)
|
||||
self._was_running = True
|
||||
self._completion_triggered = False
|
||||
|
||||
@@ -1890,7 +1892,7 @@ class BambuMQTTClient:
|
||||
# We preserve that value instead of blindly resetting to False.
|
||||
if self.state.timelapse:
|
||||
self._timelapse_during_print = True
|
||||
logger.info("[%s] Timelapse detected at print start", self.serial_number)
|
||||
logger.debug("[%s] Timelapse detected at print start", self.serial_number)
|
||||
else:
|
||||
self._timelapse_during_print = False
|
||||
|
||||
@@ -2006,7 +2008,7 @@ class BambuMQTTClient:
|
||||
if not self._client or not self.state.connected:
|
||||
logger.warning("[%s] request_status_update: not connected", self.serial_number)
|
||||
return False
|
||||
logger.info("[%s] Requesting status update (pushall)", self.serial_number)
|
||||
logger.debug("[%s] Requesting status update (pushall)", self.serial_number)
|
||||
self._request_push_all()
|
||||
# Note: get_accessories returns stale nozzle data on H2D.
|
||||
# The correct nozzle data comes from push_status response.
|
||||
@@ -2163,7 +2165,7 @@ class BambuMQTTClient:
|
||||
}
|
||||
|
||||
if is_h2d:
|
||||
logger.info(
|
||||
logger.debug(
|
||||
"[%s] H2D series detected: using integer format for calibration fields (use_ams stays boolean)",
|
||||
self.serial_number,
|
||||
)
|
||||
@@ -2172,7 +2174,7 @@ class BambuMQTTClient:
|
||||
# P2S printer doesn't support vibration calibration like X1/P1 series
|
||||
if self.model and self.model.upper().strip() in ("P2S", "N7"):
|
||||
command["print"]["vibration_cali"] = False
|
||||
logger.info("[%s] P2S detected: disabling vibration_cali", self.serial_number)
|
||||
logger.debug("[%s] P2S detected: disabling vibration_cali", self.serial_number)
|
||||
|
||||
# Add AMS mapping if provided
|
||||
if ams_mapping is not None:
|
||||
@@ -2251,7 +2253,7 @@ class BambuMQTTClient:
|
||||
|
||||
command_json = json.dumps(command)
|
||||
self._client.publish(self.topic_publish, command_json, qos=1)
|
||||
logger.info(
|
||||
logger.debug(
|
||||
"[%s] Set xcam option: %s=%s, sensitivity=%s", self.serial_number, module_name, enabled, sensitivity
|
||||
)
|
||||
logger.debug("[%s] MQTT command sent: %s", self.serial_number, command_json)
|
||||
@@ -2330,7 +2332,7 @@ class BambuMQTTClient:
|
||||
|
||||
command_json = json.dumps(command)
|
||||
self._client.publish(self.topic_publish, command_json, qos=1)
|
||||
logger.info("[%s] Set print option: %s=%s", self.serial_number, option_name, enabled)
|
||||
logger.debug("[%s] Set print option: %s=%s", self.serial_number, option_name, enabled)
|
||||
|
||||
# Set hold timer
|
||||
hold_key = f"print_option_{option_name}"
|
||||
@@ -2691,7 +2693,7 @@ class BambuMQTTClient:
|
||||
logger.info(
|
||||
f"[{self.serial_number}] Setting K-profile: {name} = {k_value} (cali_idx={effective_cali_idx}, new={slot_id == 0})"
|
||||
)
|
||||
logger.info("[%s] K-profile SET command: %s", self.serial_number, command_json)
|
||||
logger.debug("[%s] K-profile SET command: %s", self.serial_number, command_json)
|
||||
self._client.publish(self.topic_publish, command_json, qos=1)
|
||||
return True
|
||||
|
||||
@@ -2759,7 +2761,7 @@ class BambuMQTTClient:
|
||||
|
||||
command_json = json.dumps(command)
|
||||
logger.info("[%s] Setting %s K-profiles in batch", self.serial_number, len(filament_entries))
|
||||
logger.info("[%s] K-profile SET batch command: %s", self.serial_number, command_json)
|
||||
logger.debug("[%s] K-profile SET batch command: %s", self.serial_number, command_json)
|
||||
self._client.publish(self.topic_publish, command_json, qos=1)
|
||||
return True
|
||||
|
||||
@@ -2828,7 +2830,7 @@ class BambuMQTTClient:
|
||||
logger.info(
|
||||
f"[{self.serial_number}] Deleting K-profile: cali_idx={cali_idx}, filament={filament_id}, setting_id={setting_id}, dual={is_dual_nozzle}"
|
||||
)
|
||||
logger.info("[%s] K-profile DELETE command: %s", self.serial_number, command_json)
|
||||
logger.debug("[%s] K-profile DELETE command: %s", self.serial_number, command_json)
|
||||
# Use QoS 1 for reliable delivery (at least once)
|
||||
self._client.publish(self.topic_publish, command_json, qos=1)
|
||||
return True
|
||||
|
||||
Reference in New Issue