Enhanced MQTT support with separate topics and multipliers (#173)

- Add separate MQTT topics for power, energy, and state monitoring
  - mqtt_power_topic, mqtt_power_path, mqtt_power_multiplier
  - mqtt_energy_topic, mqtt_energy_path, mqtt_energy_multiplier
  - mqtt_state_topic, mqtt_state_path, mqtt_state_on_value
- Support different MQTT topics per data type (e.g., Zigbee2MQTT with
  separate power/energy/state topics)
- Individual multipliers for power and energy (e.g., mW→W, Wh→kWh)
- Configurable ON value for state monitoring (e.g., "ON", "true", "1")
- Maintain backward compatibility with legacy mqtt_topic/mqtt_multiplier
- Database migration auto-copies legacy fields to new fields
- Update backup/restore to handle new MQTT fields
- Add backend tests for new MQTT configurations
- Update frontend form with organized Power/Energy/State sections

Closes #173
This commit is contained in:
maziggy
2026-01-30 14:17:26 +01:00
parent 00e3478a3e
commit 04f4dccd41
15 changed files with 836 additions and 306 deletions
+38 -9
View File
@@ -848,11 +848,21 @@ export interface SmartPlug {
ha_energy_today_entity: string | null;
ha_energy_total_entity: string | null;
// MQTT fields (required when plug_type="mqtt")
mqtt_topic: string | null; // e.g., "zigbee2mqtt/shelly-working-room"
// Legacy field - kept for backward compatibility
mqtt_topic: string | null; // Deprecated, use mqtt_power_topic
mqtt_multiplier: number; // Deprecated, use mqtt_power_multiplier
// Power monitoring
mqtt_power_topic: string | null; // Topic for power data
mqtt_power_path: string | null; // e.g., "power_l1" or "data.power"
mqtt_power_multiplier: number; // Unit conversion for power
// Energy monitoring
mqtt_energy_topic: string | null; // Topic for energy data
mqtt_energy_path: string | null; // e.g., "energy_l1"
mqtt_energy_multiplier: number; // Unit conversion for energy
// State monitoring
mqtt_state_topic: string | null; // Topic for state data
mqtt_state_path: string | null; // e.g., "state_l1" for ON/OFF
mqtt_multiplier: number; // Unit conversion (e.g., 0.001 for mW→W)
mqtt_state_on_value: string | null; // What value means "ON" (e.g., "ON", "true", "1")
printer_id: number | null;
enabled: boolean;
auto_on: boolean;
@@ -891,11 +901,21 @@ export interface SmartPlugCreate {
ha_energy_today_entity?: string | null;
ha_energy_total_entity?: string | null;
// MQTT fields (required when plug_type="mqtt")
// Legacy fields - kept for backward compatibility
mqtt_topic?: string | null;
mqtt_power_path?: string | null;
mqtt_energy_path?: string | null;
mqtt_state_path?: string | null;
mqtt_multiplier?: number;
// Power monitoring
mqtt_power_topic?: string | null;
mqtt_power_path?: string | null;
mqtt_power_multiplier?: number;
// Energy monitoring
mqtt_energy_topic?: string | null;
mqtt_energy_path?: string | null;
mqtt_energy_multiplier?: number;
// State monitoring
mqtt_state_topic?: string | null;
mqtt_state_path?: string | null;
mqtt_state_on_value?: string | null;
printer_id?: number | null;
enabled?: boolean;
auto_on?: boolean;
@@ -926,12 +946,21 @@ export interface SmartPlugUpdate {
ha_power_entity?: string | null;
ha_energy_today_entity?: string | null;
ha_energy_total_entity?: string | null;
// MQTT fields
// MQTT fields (legacy)
mqtt_topic?: string | null;
mqtt_power_path?: string | null;
mqtt_energy_path?: string | null;
mqtt_state_path?: string | null;
mqtt_multiplier?: number;
// MQTT power fields
mqtt_power_topic?: string | null;
mqtt_power_path?: string | null;
mqtt_power_multiplier?: number;
// MQTT energy fields
mqtt_energy_topic?: string | null;
mqtt_energy_path?: string | null;
mqtt_energy_multiplier?: number;
// MQTT state fields
mqtt_state_topic?: string | null;
mqtt_state_path?: string | null;
mqtt_state_on_value?: string | null;
printer_id?: number | null;
enabled?: boolean;
auto_on?: boolean;