| binary_sensor | ||
| number | ||
| select | ||
| sensor | ||
| switch | ||
| text_sensor | ||
| README.md | ||
| __init__.py | ||
| commands.cpp | ||
| commands.h | ||
| decode.cpp | ||
| decode.h | ||
| panasonic_heatpump.cpp | ||
| panasonic_heatpump.h | ||
README.md
ESPHome Panasonic Heatpump Component
Usage
What you need
- ESPHome compatible microcontroller (e.g. ESP8266, ESP32, ESP32-S2, ESP32-C3, ...)
- Bi-Directional Logic Level Converter (to convert 5V UART signal from the heatpump to 3.3V UART signal of the ESP controller)
- CN-CNT cable to Heatpump/CZ-TAW1 (see Heishamon github site for more information)
Wiring
You may also connect the +5V pin of the heatpump to the +5V pin of the ESP board.
But for me the current (mA) provided by the heatpump was quite unstable so I powered my ESP board through an USB cable.
CN-CNT Pinout (from top to bottom)
| pin | function |
|---|---|
| 1 | +5V (250mA) |
| 2 | 0-5V TX (from heatpump) |
| 3 | 0-5V RX (to heatpump) |
| 4 | +12V (250mA) |
| 5 | GND |
ESPHome example yaml code
substitutions:
pin_rx_hp: GPIO4 # heatpump reads data (RX) on this pin
pin_tx_hp: GPIO3 # heatpump sends data (TX) on this pin
pin_tx_wm: GPIO1 # WiFi module sends data (TX) on this pin
pin_rx_wm: GPIO0 # WiFi module reads data (RX) on this pin
external_components:
- source:
type: git
url: https://github.com/ElVit/esphome_components/
components: [ panasonic_heatpump ]
uart:
- id: uart_heatpump
tx_pin: $pin_rx_hp
rx_pin: $pin_tx_hp
baud_rate: 9600
data_bits: 8
parity: EVEN
stop_bits: 1
- id: uart_cz_taw1
tx_pin: $pin_rx_wm
rx_pin: $pin_tx_wm
baud_rate: 9600
data_bits: 8
parity: EVEN
stop_bits: 1
panasonic_heatpump:
id: my_heatpump
uart_id: uart_heatpump
uart_client_id: uart_cz_taw1
log_uart_msg: false
update_interval: 3s
sensor:
- platform: panasonic_heatpump
top1:
name: "Pump Flow"
binary_sensor:
- platform: panasonic_heatpump
top0:
name: "Heatpump State"
text_sensor:
- platform: panasonic_heatpump
top4:
name: "Operating Mode State"
number:
- platform: panasonic_heatpump
set5:
name: "Set Z1 Heat Request Temperature"
select:
- platform: panasonic_heatpump
set2:
name: "Set Holiday Mode"
switch:
- platform: panasonic_heatpump
set1:
name: "Set Heatpump"
Configuration variables
- id (Optional, ID): Manually specify the ID used for actions.
- update_interval (Optional, Time): The interval of the polling request message to get the heatpump values. This time applies only if no
uart_client_idis set. Defaults to 3s. - uart_id (Optional, ID): Manually specify the UART ID of the Heatpump. Required if multiple UART buses are defined.
- uart_client_id (Optional, ID): Manually specify the UART ID of an additonal UART client like the Panasonic CZ-TAW1. If this ID is not set then your ESP controller will send the polling request messages.
- log_uart_msg (Optional, boolean): Shows the raw UART messages in the logs, if set to
true. The messages will be written to the log levelINFO. Defaults to false.
Sensors
All sensors are optional and all default sensor variables can be applied.
Here a list of all supported sensors:
sensor:
- platform: panasonic_heatpump
top1:
name: "Pump Flow"
top5:
name: "Main Inlet Temp"
top6:
name: "Main Outlet Temp"
top7:
name: "Main Target Temp"
top8:
name: "Compressor Freq"
top9:
name: "DHW Target Temp"
top10:
name: "DHW Temp"
top11:
name: "Operations Hours"
top12:
name: "Operations Counter"
top14:
name: "Outside Temp"
top15:
name: "Heat Power Production"
top16:
name: "Heat Power Consumption"
top21:
name: "Outside Pipe Temp"
top22:
name: "DHW Heat Delta"
top23:
name: "Heat Delta"
top24:
name: "Cool Delta"
top25:
name: "DHW Holiday Shift Temp"
top27:
name: "Z1 Heat Request Temp"
top28:
name: "Z1 Cool Request Temp"
top29:
name: "Z1 Heat Curve Target High Temp"
top30:
name: "Z1 Heat Curve Target Low Temp"
top31:
name: "Z1 Heat Curve Outside High Temp"
top32:
name: "Z1 Heat Curve Outside Low Temp"
top33:
name: "Room Thermostat Temp"
top34:
name: "Z2 Heat Request Temp"
top35:
name: "Z2 Cool Request Temp"
top36:
name: "Z1 Water Temp"
top37:
name: "Z2 Water Temp"
top38:
name: "Cool Power Production"
top39:
name: "Cool Power Consumption"
top40:
name: "DHW Power Production"
top41:
name: "DHW Power Consumption"
top42:
name: "Z1 Water Target Temp"
top43:
name: "Z2 Water Target Temp"
top45:
name: "Room Holiday Shift Temp"
top46:
name: "Buffer Temp"
top47:
name: "Solar Temp"
top48:
name: "Pool Temp"
top49:
name: "Main Hex Outlet Temp"
top50:
name: "Discharge Temp"
top51:
name: "Inside Pipe Temp"
top52:
name: "Defrost Temp"
top53:
name: "Eva Outlet Temp"
top54:
name: "Bypass Outlet Temp"
top55:
name: "Ipm Temp"
top56:
name: "Z1 Temp"
top57:
name: "Z2 Temp"
top62:
name: "Fan1 Motor Speed"
top63:
name: "Fan2 Motor Speed"
top64:
name: "High Pressure"
top65:
name: "Pump Speed"
top66:
name: "Low Pressure"
top67:
name: "Compressor Current"
top70:
name: "Sterilization Temp"
top71:
name: "Sterilization Max Time"
top72:
name: "Z1 Cool Curve Target High Temp"
top73:
name: "Z1 Cool Curve Target Low Temp"
top74:
name: "Z1 Cool Curve Outside High Temp"
top75:
name: "Z1 Cool Curve Outside Low Temp"
top77:
name: "Heating Off Outdoor Temp"
top78:
name: "Heater On Outdoor Temp"
top79:
name: "Heat To Cool Temp"
top80:
name: "Cool To Heat Temp"
top82:
name: "Z2 Heat Curve Target High Temp"
top83:
name: "Z2 Heat Curve Target Low Temp"
top84:
name: "Z2 Heat Curve Outside High Temp"
top85:
name: "Z2 Heat Curve Outside Low Temp"
top86:
name: "Z2 Cool Curve Target High Temp"
top87:
name: "Z2 Cool Curve Target Low Temp"
top88:
name: "Z2 Cool Curve Outside High Temp"
top89:
name: "Z2 Cool Curve Outside Low Temp"
top90:
name: "Room Heater Operations Hours"
top91:
name: "DHW Heater Operations Hours"
top93:
name: "Pump Duty"
top95:
name: "Max Pump Duty"
top96:
name: "Heater Delay Time"
top97:
name: "Heater Start Delta"
top98:
name: "Heater Stop Delta"
top102:
name: "Solar On Delta"
top103:
name: "Solar Off Delta"
top104:
name: "Solar Frost Protection"
top105:
name: "Solar High Limit"
top113:
name: "Buffer Tank Delta"
top115:
name: "Water Pressure"
top116:
name: "Second Inlet Temp"
top117:
name: "Economizer Outlet Temp"
top118:
name: "Second Room Thermostat Temp"
top127:
name: "Z1 Valve PID"
top128:
name: "Z2 Valve PID"
top131:
name: "Bivalent Start Temperature"
top134:
name: "Bivalent Advanced Start Temp"
top135:
name: "Bivalent Advanced Stop Temp"
top136:
name: "Bivalent Advanced Start Delay"
top137:
name: "Bivalent Advanced Stop Delay"
top138:
name: "Bivalent Advanced DHW Delay"
Binary Sensors
All binary sensors are optional and all default binary sensor variables can be applied.
Here a list of all supported binary sensors:
binary_sensor:
- platform: panasonic_heatpump
top0:
name: "Heatpump State"
top2:
name: "Force DHW State"
top3:
name: "Quiet Mode Schedule"
top13:
name: "Main Schedule State"
top26:
name: "Defrosting State"
top60:
name: "Internal Heater State"
top61:
name: "External Heater State"
top68:
name: "Force Heater State"
top69:
name: "Sterilization State"
top99:
name: "Buffer Installed"
top100:
name: "DHW Installed"
top108:
name: "Alt External Sensor"
top109:
name: "Anti Freeze Mode"
top110:
name: "Optional PCB"
top119:
name: "External Control"
top120:
name: "External Heat Cool Control"
top121:
name: "External Error Signal"
top122:
name: "External Compressor Control"
top123:
name: "Z2 Pump State"
top124:
name: "Z1 Pump State"
top129:
name: "Bivalent Control"
top132:
name: "Bivalent Advanced Heat"
top133:
name: "Bivalent Advanced DHW"
Text Sensors
All text sensors are optional and all default text sensor variables can be applied.
Here a list of all supported text sensors:
text_sensor:
- platform: panasonic_heatpump
top4:
name: "Operating Mode State"
top17:
name: "Powerful Mode Time"
top18:
name: "Quiet Mode Level"
top19:
name: "Holiday Mode State"
top20:
name: "ThreeWay Valve State"
top44:
name: "Error"
top58:
name: "DHW Heater State"
top59:
name: "Room Heater State"
top76:
name: "Heating Mode"
top81:
name: "Cooling Mode"
top92:
name: "Heat Pump Model"
top94:
name: "Zones State"
top101:
name: "Solar Mode"
top106:
name: "Pump Flowrate Mode"
top107:
name: "Liquid Type"
top111:
name: "Z1 Sensor Settings"
top112:
name: "Z2 Sensor Settings"
top114:
name: "External Pad Heater"
top125:
name: "TwoWay Valve State"
top126:
name: "ThreeWay Valve State2"
top130:
name: "Bivalent Mode"
Numbers
All numbers are optional and all default number variables can be applied.
Here a list of all supported numbers:
number:
- platform: panasonic_heatpump
set5:
name: "Set Z1 Heat Request Temperature"
set6:
name: "Set Z1 Cool Request Temperature"
set7:
name: "Set Z2 Heat Request Temperature"
set8:
name: "Set Z2 Cool Request Temperature"
set11:
name: "Set DHW Temp"
set15:
name: "Set Max Pump Duty"
set16_1:
name: "Set Zone1 Heat Target High"
set16_2:
name: "Set Zone1 Heat Target Low"
set16_3:
name: "Set Zone1 Heat Outside Low"
set16_4:
name: "Set Zone1 Heat Outside High"
set16_5:
name: "Set Zone2 Heat Target High"
set16_6:
name: "Set Zone2 Heat Target Low"
set16_7:
name: "Set Zone2 Heat Outside Low"
set16_8:
name: "Set Zone2 Heat Outside High"
set16_9:
name: "Set Zone1 Cool Target High"
set16_10:
name: "Set Zone1 Cool Target Low"
set16_11:
name: "Set Zone1 Cool Outside Low"
set16_12:
name: "Set Zone1 Cool Outside High"
set16_13:
name: "Set Zone2 Cool Target High"
set16_14:
name: "Set Zone2 Cool Target Low"
set16_15:
name: "Set Zone2 Cool Outside Low"
set16_16:
name: "Set Zone2 Cool Outside High"
set18:
name: "Set Floor Heat Delta"
set19:
name: "Set Floor Cool Delta"
set20:
name: "Set DHW Heat Delta"
set21:
name: "Set Heater Delay Time"
set22:
name: "Set Heater Start Delta"
set23:
name: "Set Heater Stop Delta"
set27:
name: "Set Buffer Delta"
set29:
name: "Set Heating Off Outdoor Temp"
set36:
name: "Set Bivalent Start Temp"
set37:
name: "Set Bivalent AP Start Temp"
set38:
name: "Set Bivalent AP Stop Temp"
Switches
All switches are optional and all default switch variables can be applied.
Here a list of all supported switches:
switch:
- platform: panasonic_heatpump
set1:
name: "Set Heatpump"
set10:
name: "Set Force DHW"
set12:
name: "Set Force Defrost"
set13:
name: "Set Force Sterilization"
set14:
name: "Set Pump"
set24:
name: "Set Main Schedule"
set25:
name: "Set Alt External Sensor"
set28:
name: "Set Buffer"
set30:
name: "Set External Control"
set31:
name: "Set External Error"
set32:
name: "Set External Compressor Control"
set33:
name: "Set External Heat Cool Control"
set34:
name: "Set Bivalent Control"
Selects
All selects are optional and all default select variables can be applied.
Here a list of all supported selects:
select:
- platform: panasonic_heatpump
set2:
name: "Set Holiday Mode"
set3:
name: "Set Quiet Mode"
set4:
name: "Set Powerful Mode"
set9:
name: "Set Operation Mode"
set17:
name: "Set Zones"
set26:
name: "Set External PadHeater"
set35:
name: "Set Bivalent Mode"
Custom Entities (For Advanced Users)
If you review the ProtocolByteDecrypt.md file you will find also some TOPs and SETs which are not implemented yet in heishamon.
They are usually marked as TOP (without a number).
The nice part of ESPHome is that it is so highly customizeable.
So if you want some additional TOP or SET entities you can easily create your own.
Under the hood the received uart message from the heatpump is stored in a vector.
Here are 2 examples how to create a sensor and a text_sensor:
sensor:
- platform: template
name: "Dry concrete target temperature for actual stage"
update_interval: 3s
device_class: temperature
unit_of_measurement: °C
lambda: |-
// get the requried byte
int byte = my_heatpump->getResponseByte(46);
if (byte < 0) return {};
// convert the byte (see HeishaMon/ProtocolByteDecrypt.md)
// in this case -128
return byte - 128;
text_sensor:
- platform: template
name: "DHW capacity (J-series only)"
update_interval: 3s
lambda: |-
// get the requried byte
int byte = my_heatpump->getResponseByte(9);
if (byte < 0) return {};
// convert the byte (see HeishaMon/ProtocolByteDecrypt.md)
// in this case 3rd and 4th bit (--> b0011 0000)
int state = ((byte >> 4) & 0b11) - 1;
// set text
if (state == 0) return { "Standard" };
if (state == 1) return { "DHW" };
// if state is unkown do not update text
return {};
Known Issues
When the ESP controller is connected initially to the heatpump, the heatpump may not respond to any request messages. If the CZ-TAW1 is also connected to the ESP controller you will probably see some requests like 31 05 10 01 ... These are initial request messages. If the heatpump is not responding, it may help to turn off and on the power of the heatpump (switching the heatpump off is not enough). After a power on the heatpump should respond to the requests.
Sources
❤️ A big THANKS to Egyras and the work done on the repository HeishaMon for decoding the panasonic uart protocol and providing information to build hardware based on an ESP Chip.
❤️ Thanks to the whole home assistant community for sharing their knowlege and helping me to create this ESPHome component!