esp32: board: lolin_s2_mini variant: ESP32S2 framework: type: esp-idf esphome: name: panasonic-heatpump friendly_name: Panasonic Heatpump ota: platform: esphome password: !secret ota_password api: encryption: key: !secret ha_api_key wifi: ssid: !secret wifi_ssid password: !secret wifi_password ap: ssid: "Panasonic Heatpump Fallback" password: !secret fallback_password logger: external_components: - source: type: git url: https://github.com/ElVit/esphome_components/ components: [ panasonic_heatpump ] uart: - id: uart_heatpump tx_pin: GPIO37 # heatpump reads data (RX) on this pin (yellow) rx_pin: GPIO39 # heatpump sends data (TX) on this pin (green) baud_rate: 9600 data_bits: 8 parity: EVEN stop_bits: 1 - id: uart_cz_taw1 tx_pin: GPIO16 # WiFi module reads data (RX) on this pin (blue) rx_pin: GPIO18 # WiFi module sends data (TX) on this pin (white) baud_rate: 9600 data_bits: 8 parity: EVEN stop_bits: 1 panasonic_heatpump: id: my_heatpump uart_id: uart_heatpump uart_client_id: uart_cz_taw1 log_uart_msg: true update_interval: 3s sensor: - platform: panasonic_heatpump top1: name: "Pump Flow" top5: name: "Main Inlet Temp" top6: name: "Main Outlet Temp" top7: name: "Main Target Temp" top8: name: "Compressor Freq" top9: name: "DHW Target Temp" top10: name: "DHW Temp" top11: name: "Operations Hours" top12: name: "Operations Counter" top14: name: "Outside Temp" top15: name: "Heat Power Production" top16: name: "Heat Power Consumption" id: heat_power_consumption top21: name: "Outside Pipe Temp" top22: name: "DHW Heat Delta" top23: name: "Heat Delta" top24: name: "Cool Delta" top25: name: "DHW Holiday Shift Temp" top27: name: "Z1 Heat Request Temp" top28: name: "Z1 Cool Request Temp" top29: name: "Z1 Heat Curve Target High Temp" top30: name: "Z1 Heat Curve Target Low Temp" top31: name: "Z1 Heat Curve Outside High Temp" top32: name: "Z1 Heat Curve Outside Low Temp" top33: name: "Room Thermostat Temp" top34: name: "Z2 Heat Request Temp" top35: name: "Z2 Cool Request Temp" top36: name: "Z1 Water Temp" top37: name: "Z2 Water Temp" top38: name: "Cool Power Production" top39: name: "Cool Power Consumption" id: cool_power_consumption top40: name: "DHW Power Production" top41: name: "DHW Power Consumption" id: dhw_power_consumption top42: name: "Z1 Water Target Temp" top43: name: "Z2 Water Target Temp" top45: name: "Room Holiday Shift Temp" top46: name: "Buffer Temp" top47: name: "Solar Temp" top48: name: "Pool Temp" top49: name: "Main Hex Outlet Temp" top50: name: "Discharge Temp" top51: name: "Inside Pipe Temp" top52: name: "Defrost Temp" top53: name: "Eva Outlet Temp" top54: name: "Bypass Outlet Temp" top55: name: "Ipm Temp" top56: name: "Z1 Temp" top57: name: "Z2 Temp" top62: name: "Fan1 Motor Speed" top63: name: "Fan2 Motor Speed" top64: name: "High Pressure" top65: name: "Pump Speed" top66: name: "Low Pressure" top67: name: "Compressor Current" top70: name: "Sterilization Temp" top71: name: "Sterilization Max Time" top72: name: "Z1 Cool Curve Target High Temp" top73: name: "Z1 Cool Curve Target Low Temp" top74: name: "Z1 Cool Curve Outside High Temp" top75: name: "Z1 Cool Curve Outside Low Temp" top77: name: "Heating Off Outdoor Temp" top78: name: "Heater On Outdoor Temp" top79: name: "Heat To Cool Temp" top80: name: "Cool To Heat Temp" top82: name: "Z2 Heat Curve Target High Temp" top83: name: "Z2 Heat Curve Target Low Temp" top84: name: "Z2 Heat Curve Outside High Temp" top85: name: "Z2 Heat Curve Outside Low Temp" top86: name: "Z2 Cool Curve Target High Temp" top87: name: "Z2 Cool Curve Target Low Temp" top88: name: "Z2 Cool Curve Outside High Temp" top89: name: "Z2 Cool Curve Outside Low Temp" top90: name: "Room Heater Operations Hours" top91: name: "DHW Heater Operations Hours" top93: name: "Pump Duty" top95: name: "Max Pump Duty" top96: name: "Heater Delay Time" top97: name: "Heater Start Delta" top98: name: "Heater Stop Delta" top102: name: "Solar On Delta" top103: name: "Solar Off Delta" top104: name: "Solar Frost Protection" top105: name: "Solar High Limit" top113: name: "Buffer Tank Delta" top115: name: "Water Pressure" top116: name: "Second Inlet Temp" top117: name: "Economizer Outlet Temp" top118: name: "Second Room Thermostat Temp" top127: name: "Z1 Valve PID" top128: name: "Z2 Valve PID" top131: name: "Bivalent Start Temperature" top134: name: "Bivalent Advanced Start Temp" top135: name: "Bivalent Advanced Stop Temp" top136: name: "Bivalent Advanced Start Delay" top137: name: "Bivalent Advanced Stop Delay" top138: name: "Bivalent Advanced DHW Delay" top142: name: "Expansion Valve" xtop0: name: "Heat Power Consumption Extra" xtop1: name: "Cool Power Consumption Extra" xtop2: name: "DHW Power Consumption Extra" xtop3: name: "Heat Power Production Extra" xtop4: name: "Cool Power Production Extra" xtop5: name: "DHW Power Production Extra" - platform: total_daily_energy name: Heat Power Consumption Daily power_id: heat_power_consumption unit_of_measurement: kWh state_class: total_increasing device_class: energy accuracy_decimals: 3 filters: - multiply: 0.001 - platform: total_daily_energy name: Cool Power Consumption Daily power_id: cool_power_consumption unit_of_measurement: kWh state_class: total_increasing device_class: energy accuracy_decimals: 3 filters: - multiply: 0.001 - platform: total_daily_energy name: DHW Power Consumption Daily power_id: dhw_power_consumption unit_of_measurement: kWh state_class: total_increasing device_class: energy accuracy_decimals: 3 filters: - multiply: 0.001 binary_sensor: - platform: panasonic_heatpump top0: name: "Heatpump State" top2: name: "Force DHW State" top3: name: "Quiet Mode Schedule" top13: name: "Main Schedule State" top26: name: "Defrosting State" top60: name: "Internal Heater State" top61: name: "External Heater State" top68: name: "Force Heater State" top69: name: "Sterilization State" top99: name: "Buffer Installed" top100: name: "DHW Installed" top108: name: "Alt External Sensor" top109: name: "Anti Freeze Mode" top110: name: "Optional PCB" top119: name: "External Control" top120: name: "External Heat Cool Control" top121: name: "External Error Signal" top122: name: "External Compressor Control" top123: name: "Z2 Pump State" top124: name: "Z1 Pump State" top129: name: "Bivalent Control" top132: name: "Bivalent Advanced Heat" top133: name: "Bivalent Advanced DHW" text_sensor: - platform: panasonic_heatpump top4: name: "Operating Mode State" top17: name: "Powerful Mode Time" top18: name: "Quiet Mode Level" top19: name: "Holiday Mode State" top20: name: "ThreeWay Valve State" top44: name: "Error" top58: name: "DHW Heater State" top59: name: "Room Heater State" top76: name: "Heating Mode" top81: name: "Cooling Mode" top92: name: "Heat Pump Model" top94: name: "Zones State" top101: name: "Solar Mode" top106: name: "Pump Flowrate Mode" top107: name: "Liquid Type" top111: name: "Z1 Sensor Settings" top112: name: "Z2 Sensor Settings" top114: name: "External Pad Heater" top125: name: "TwoWay Valve State" top126: name: "ThreeWay Valve State2" top130: name: "Bivalent Mode" top139: name: "HeatingControl" top140: name: "SmartDHW" top141: name: "Quiet Mode Priority" top143: name: "DHW Sensor Selection" number: - platform: panasonic_heatpump set5: name: "Set Z1 Heat Request Temperature" set6: name: "Set Z1 Cool Request Temperature" set7: name: "Set Z2 Heat Request Temperature" set8: name: "Set Z2 Cool Request Temperature" set11: name: "Set DHW Temp" set15: name: "Set Max Pump Duty" set16_01: name: "Set Zone1 Heat Target High" set16_02: name: "Set Zone1 Heat Target Low" set16_03: name: "Set Zone1 Heat Outside Low" set16_04: name: "Set Zone1 Heat Outside High" set16_05: name: "Set Zone2 Heat Target High" set16_06: name: "Set Zone2 Heat Target Low" set16_07: name: "Set Zone2 Heat Outside Low" set16_08: name: "Set Zone2 Heat Outside High" set16_09: name: "Set Zone1 Cool Target High" set16_10: name: "Set Zone1 Cool Target Low" set16_11: name: "Set Zone1 Cool Outside Low" set16_12: name: "Set Zone1 Cool Outside High" set16_13: name: "Set Zone2 Cool Target High" set16_14: name: "Set Zone2 Cool Target Low" set16_15: name: "Set Zone2 Cool Outside Low" set16_16: name: "Set Zone2 Cool Outside High" set18: name: "Set Floor Heat Delta" set19: name: "Set Floor Cool Delta" set20: name: "Set DHW Heat Delta" set21: name: "Set Heater Delay Time" set22: name: "Set Heater Start Delta" set23: name: "Set Heater Stop Delta" set27: name: "Set Buffer Delta" set29: name: "Set Heating Off Outdoor Temp" set36: name: "Set Bivalent Start Temp" set37: name: "Set Bivalent AP Start Temp" set38: name: "Set Bivalent AP Stop Temp" set46: name: "Set Heater On Outdoor Temp" set47: name: "Set Heat To Cool Temp" set48: name: "Set Cool To Heat Temp" switch: - platform: panasonic_heatpump set1: name: "Set Heatpump" set10: name: "Set Force DHW" set12: name: "Set Force Defrost" set13: name: "Set Force Sterilization" set14: name: "Set Pump" set24: name: "Set Main Schedule" set25: name: "Set Alt External Sensor" set28: name: "Set Buffer" set30: name: "Set External Control" set31: name: "Set External Error" set32: name: "Set External Compressor Control" set33: name: "Set External Heat Cool Control" set34: name: "Set Bivalent Control" error_reset: name: "Error Reset (Restart Heatpump)" select: - platform: panasonic_heatpump cool_mode: true set2: name: "Set Holiday Mode" set3: name: "Set Quiet Mode" set4: name: "Set Powerful Mode" set9: name: "Set Operation Mode" set17: name: "Set Zones" set26: name: "Set External PadHeater" set35: name: "Set Bivalent Mode" set39: name: "Set Heating Control" set40: name: "Set Smart DHW" set41: name: "Set Quiet Mode Priority" set42: name: "Set Pump Flow Rate Mode" set43: name: "Set DHW Sensor Selection" set44: name: "Set DHW Heater State" set45: name: "Set Room Heater State" climate: - platform: panasonic_heatpump cool_mode: true zone1: name: "Zone 1" zone2: name: "Zone 2" water_heater: - platform: panasonic_heatpump tank: name: "DHW"