diff --git a/components/panasonic_heatpump/README.md b/components/panasonic_heatpump/README.md index 0520be9..bac95ee 100644 --- a/components/panasonic_heatpump/README.md +++ b/components/panasonic_heatpump/README.md @@ -555,6 +555,10 @@ number: name: "Set Bivalent AP Stop Temp" set46: name: "Set Heater On Outdoor Temp" + set47: + name: "Set Heat To Cool Temp" + set48: + name: "Set Cool To Heat Temp" ``` ### Switches diff --git a/components/panasonic_heatpump/number/__init__.py b/components/panasonic_heatpump/number/__init__.py index d731d2a..4c8d57f 100644 --- a/components/panasonic_heatpump/number/__init__.py +++ b/components/panasonic_heatpump/number/__init__.py @@ -51,6 +51,8 @@ CONF_SET36 = "set36" # Set Bivalent Start Temp CONF_SET37 = "set37" # Set Bivalent AP Start Temp CONF_SET38 = "set38" # Set Bivalent AP Stop Temp CONF_SET46 = "set46" # Set Heater On Outdoor Temp +CONF_SET47 = "set47" # Set Heat To Cool Temp +CONF_SET48 = "set48" # Set Cool To Heat Temp TYPES = [ CONF_SET5, @@ -87,6 +89,8 @@ TYPES = [ CONF_SET37, CONF_SET38, CONF_SET46, + CONF_SET47, + CONF_SET48, ] @@ -264,6 +268,14 @@ CONFIG_SCHEMA = cv.Schema( PanasonicHeatpumpNumber, unit_of_measurement=UNIT_CELSIUS, ).extend(number_options(-15.0, 20.0, 1.0)), + cv.Optional(CONF_SET47): number.number_schema( + PanasonicHeatpumpNumber, + unit_of_measurement=UNIT_CELSIUS + ).extend(number_options(11.0, 25.0, 1.0)), + cv.Optional(CONF_SET48): number.number_schema( + PanasonicHeatpumpNumber, + unit_of_measurement=UNIT_CELSIUS + ).extend(number_options(5.0, 14.0, 1.0)), } ).extend(cv.COMPONENT_SCHEMA) diff --git a/components/panasonic_heatpump/number/panasonic_heatpump_number.cpp b/components/panasonic_heatpump/number/panasonic_heatpump_number.cpp index d1b3bde..8fa2430 100644 --- a/components/panasonic_heatpump/number/panasonic_heatpump_number.cpp +++ b/components/panasonic_heatpump/number/panasonic_heatpump_number.cpp @@ -114,6 +114,12 @@ void PanasonicHeatpumpNumber::control(float value) { case NumberIds::CONF_SET46: this->parent_->set_command_byte(PanasonicCommand::setPlus128(value_int), 85); break; + case NumberIds::CONF_SET47: + this->parent_->set_command_byte(PanasonicCommand::setPlus128(value_int), 95); + break; + case NumberIds::CONF_SET48: + this->parent_->set_command_byte(PanasonicCommand::setPlus128(value_int), 96); + break; default: return; }; @@ -302,6 +308,16 @@ void PanasonicHeatpumpNumber::publish_new_state(const std::vector& data if (this->has_state() && this->state == new_state) return; break; + case NumberIds::CONF_SET47: + new_state = PanasonicDecode::getByteMinus128(data[95]); + if (this->has_state() && this->state == new_state) + return; + break; + case NumberIds::CONF_SET48: + new_state = PanasonicDecode::getByteMinus128(data[96]); + if (this->has_state() && this->state == new_state) + return; + break; default: return; }; diff --git a/components/panasonic_heatpump/number/panasonic_heatpump_number.h b/components/panasonic_heatpump/number/panasonic_heatpump_number.h index 6d15614..2fe3361 100644 --- a/components/panasonic_heatpump/number/panasonic_heatpump_number.h +++ b/components/panasonic_heatpump/number/panasonic_heatpump_number.h @@ -42,6 +42,8 @@ enum NumberIds : uint8_t { CONF_SET37, CONF_SET38, CONF_SET46, + CONF_SET47, + CONF_SET48, }; class PanasonicHeatpumpNumber : public number::Number, diff --git a/example_panasonic_heatpump.yaml b/example_panasonic_heatpump.yaml index 3f1d465..0eb9b57 100644 --- a/example_panasonic_heatpump.yaml +++ b/example_panasonic_heatpump.yaml @@ -392,6 +392,8 @@ text_sensor: name: "SmartDHW" top141: name: "Quiet Mode Priority" + top143: + name: "DHW Sensor Selection" number: - platform: panasonic_heatpump @@ -461,6 +463,12 @@ number: name: "Set Bivalent AP Start Temp" set38: name: "Set Bivalent AP Stop Temp" + set46: + name: "Set Heater On Outdoor Temp" + set47: + name: "Set Heat To Cool Temp" + set48: + name: "Set Cool To Heat Temp" switch: - platform: panasonic_heatpump @@ -490,6 +498,8 @@ switch: name: "Set External Heat Cool Control" set34: name: "Set Bivalent Control" + error_reset: + name: "Error Reset (Restart Heatpump)" select: - platform: panasonic_heatpump @@ -516,6 +526,12 @@ select: name: "Set Quiet Mode Priority" set42: name: "Set Pump Flow Rate Mode" + set43: + name: "Set DHW Sensor Selection" + set44: + name: "Set DHW Heater State" + set45: + name: "Set Room Heater State" climate: - platform: panasonic_heatpump