Merge pull request #36 from ElVit/heatpump/new_controls
This commit is contained in:
commit
dd48334147
|
|
@ -555,6 +555,10 @@ number:
|
||||||
name: "Set Bivalent AP Stop Temp"
|
name: "Set Bivalent AP Stop Temp"
|
||||||
set46:
|
set46:
|
||||||
name: "Set Heater On Outdoor Temp"
|
name: "Set Heater On Outdoor Temp"
|
||||||
|
set47:
|
||||||
|
name: "Set Heat To Cool Temp"
|
||||||
|
set48:
|
||||||
|
name: "Set Cool To Heat Temp"
|
||||||
```
|
```
|
||||||
|
|
||||||
### Switches
|
### Switches
|
||||||
|
|
|
||||||
|
|
@ -94,6 +94,12 @@ constexpr const uint8_t KnownModels[NUMBER_OF_MODELS][10] = {
|
||||||
{0xE2, 0xD5, 0x0C, 0x29, 0x99, 0x83, 0x92, 0x0C, 0x29, 0x98}, // 64
|
{0xE2, 0xD5, 0x0C, 0x29, 0x99, 0x83, 0x92, 0x0C, 0x29, 0x98}, // 64
|
||||||
{0x62, 0xD2, 0x0B, 0x45, 0x54, 0x42, 0xD2, 0x0B, 0x72, 0x66}, // 65
|
{0x62, 0xD2, 0x0B, 0x45, 0x54, 0x42, 0xD2, 0x0B, 0x72, 0x66}, // 65
|
||||||
{0xE2, 0xCF, 0x0B, 0x82, 0x09, 0x12, 0xD0, 0x0B, 0x10, 0x11}, // 66
|
{0xE2, 0xCF, 0x0B, 0x82, 0x09, 0x12, 0xD0, 0x0B, 0x10, 0x11}, // 66
|
||||||
|
{0x42, 0xD4, 0x0B, 0x83, 0x71, 0x32, 0xD2, 0x0C, 0x45, 0x55}, // 67
|
||||||
|
{0x12, 0xD7, 0x0B, 0x47, 0x19, 0x37, 0x94, 0x0E, 0x83, 0x10}, // 68
|
||||||
|
{0xE2, 0xD5, 0x0D, 0x00, 0x09, 0x43, 0xD6, 0x0E, 0x07, 0x09}, // 69
|
||||||
|
{0xE2, 0xCF, 0x0B, 0x84, 0x05, 0x12, 0xD0, 0x0B, 0x93, 0x05}, // 70
|
||||||
|
{0xE2, 0xD5, 0x0B, 0x35, 0x99, 0x83, 0x92, 0x0D, 0x29, 0x98}, // 71
|
||||||
|
{0x12, 0xD7, 0x0B, 0x98, 0x14, 0x35, 0x94, 0x0D, 0x83, 0x10}, // 72
|
||||||
};
|
};
|
||||||
|
|
||||||
int PanasonicDecode::getBit1(uint8_t input) {
|
int PanasonicDecode::getBit1(uint8_t input) {
|
||||||
|
|
|
||||||
|
|
@ -7,7 +7,7 @@
|
||||||
#define RESPONSE_MSG_SIZE 203
|
#define RESPONSE_MSG_SIZE 203
|
||||||
#endif
|
#endif
|
||||||
#ifndef NUMBER_OF_MODELS
|
#ifndef NUMBER_OF_MODELS
|
||||||
#define NUMBER_OF_MODELS 67
|
#define NUMBER_OF_MODELS 73
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
namespace esphome {
|
namespace esphome {
|
||||||
|
|
@ -72,7 +72,7 @@ class PanasonicDecode {
|
||||||
static const constexpr char* const QuietModePriority[] = {"2", "Sound", "Capacity"};
|
static const constexpr char* const QuietModePriority[] = {"2", "Sound", "Capacity"};
|
||||||
static const constexpr char* const DHWSensorSelection[] = {"2", "Top", "Center"};
|
static const constexpr char* const DHWSensorSelection[] = {"2", "Top", "Center"};
|
||||||
static const constexpr char* const ModelNames[] = {
|
static const constexpr char* const ModelNames[] = {
|
||||||
"67", // string representation of number of known models (last model number + 1)
|
"73", // string representation of number of known models (last model number + 1)
|
||||||
"WH-MDC05H3E5", // 0
|
"WH-MDC05H3E5", // 0
|
||||||
"WH-MDC07H3E5", // 1
|
"WH-MDC07H3E5", // 1
|
||||||
"IDU:WH-SXC09H3E5, ODU:WH-UX09HE5", // 2
|
"IDU:WH-SXC09H3E5, ODU:WH-UX09HE5", // 2
|
||||||
|
|
@ -140,6 +140,12 @@ class PanasonicDecode {
|
||||||
"IDU:WH-ADC0509L3E5, ODU:WH-WDG09LE5", // 64
|
"IDU:WH-ADC0509L3E5, ODU:WH-WDG09LE5", // 64
|
||||||
"IDU:WH-ADC0309J3E5, ODU:WH-UD09JE5-1", // 65
|
"IDU:WH-ADC0309J3E5, ODU:WH-UD09JE5-1", // 65
|
||||||
"IDU:WH-SDC12H6E5, ODU:WH-UD12HE5", // 66
|
"IDU:WH-SDC12H6E5, ODU:WH-UD12HE5", // 66
|
||||||
|
"IDU:WH-ADC0309J3E5C, ODU:WH-UD05JE5", // 67
|
||||||
|
"IDU:WH-ADC0316M9E83, ODU:WH-WXG09ME8", // 68
|
||||||
|
"IDU:WH-SDC09K3E8, ODU:WH-UDZ09KE8", // 69
|
||||||
|
"IDU:WH-SQC16H9E8, ODU:WH-UQ16HE8", // 70
|
||||||
|
"IDU:WH-SDC0509L6E5, ODU:WH-WDG09LE5", // 71
|
||||||
|
"IDU:WH-SDC0316M9E8, ODU:WH-WXG09ME8", // 72
|
||||||
};
|
};
|
||||||
};
|
};
|
||||||
|
|
||||||
|
|
|
||||||
|
|
@ -51,6 +51,8 @@ CONF_SET36 = "set36" # Set Bivalent Start Temp
|
||||||
CONF_SET37 = "set37" # Set Bivalent AP Start Temp
|
CONF_SET37 = "set37" # Set Bivalent AP Start Temp
|
||||||
CONF_SET38 = "set38" # Set Bivalent AP Stop Temp
|
CONF_SET38 = "set38" # Set Bivalent AP Stop Temp
|
||||||
CONF_SET46 = "set46" # Set Heater On Outdoor Temp
|
CONF_SET46 = "set46" # Set Heater On Outdoor Temp
|
||||||
|
CONF_SET47 = "set47" # Set Heat To Cool Temp
|
||||||
|
CONF_SET48 = "set48" # Set Cool To Heat Temp
|
||||||
|
|
||||||
TYPES = [
|
TYPES = [
|
||||||
CONF_SET5,
|
CONF_SET5,
|
||||||
|
|
@ -87,6 +89,8 @@ TYPES = [
|
||||||
CONF_SET37,
|
CONF_SET37,
|
||||||
CONF_SET38,
|
CONF_SET38,
|
||||||
CONF_SET46,
|
CONF_SET46,
|
||||||
|
CONF_SET47,
|
||||||
|
CONF_SET48,
|
||||||
]
|
]
|
||||||
|
|
||||||
|
|
||||||
|
|
@ -264,6 +268,14 @@ CONFIG_SCHEMA = cv.Schema(
|
||||||
PanasonicHeatpumpNumber,
|
PanasonicHeatpumpNumber,
|
||||||
unit_of_measurement=UNIT_CELSIUS,
|
unit_of_measurement=UNIT_CELSIUS,
|
||||||
).extend(number_options(-15.0, 20.0, 1.0)),
|
).extend(number_options(-15.0, 20.0, 1.0)),
|
||||||
|
cv.Optional(CONF_SET47): number.number_schema(
|
||||||
|
PanasonicHeatpumpNumber,
|
||||||
|
unit_of_measurement=UNIT_CELSIUS,
|
||||||
|
).extend(number_options(11.0, 25.0, 1.0)),
|
||||||
|
cv.Optional(CONF_SET48): number.number_schema(
|
||||||
|
PanasonicHeatpumpNumber,
|
||||||
|
unit_of_measurement=UNIT_CELSIUS,
|
||||||
|
).extend(number_options(5.0, 14.0, 1.0)),
|
||||||
}
|
}
|
||||||
).extend(cv.COMPONENT_SCHEMA)
|
).extend(cv.COMPONENT_SCHEMA)
|
||||||
|
|
||||||
|
|
|
||||||
|
|
@ -114,6 +114,12 @@ void PanasonicHeatpumpNumber::control(float value) {
|
||||||
case NumberIds::CONF_SET46:
|
case NumberIds::CONF_SET46:
|
||||||
this->parent_->set_command_byte(PanasonicCommand::setPlus128(value_int), 85);
|
this->parent_->set_command_byte(PanasonicCommand::setPlus128(value_int), 85);
|
||||||
break;
|
break;
|
||||||
|
case NumberIds::CONF_SET47:
|
||||||
|
this->parent_->set_command_byte(PanasonicCommand::setPlus128(value_int), 95);
|
||||||
|
break;
|
||||||
|
case NumberIds::CONF_SET48:
|
||||||
|
this->parent_->set_command_byte(PanasonicCommand::setPlus128(value_int), 96);
|
||||||
|
break;
|
||||||
default:
|
default:
|
||||||
return;
|
return;
|
||||||
};
|
};
|
||||||
|
|
@ -302,6 +308,16 @@ void PanasonicHeatpumpNumber::publish_new_state(const std::vector<uint8_t>& data
|
||||||
if (this->has_state() && this->state == new_state)
|
if (this->has_state() && this->state == new_state)
|
||||||
return;
|
return;
|
||||||
break;
|
break;
|
||||||
|
case NumberIds::CONF_SET47:
|
||||||
|
new_state = PanasonicDecode::getByteMinus128(data[95]);
|
||||||
|
if (this->has_state() && this->state == new_state)
|
||||||
|
return;
|
||||||
|
break;
|
||||||
|
case NumberIds::CONF_SET48:
|
||||||
|
new_state = PanasonicDecode::getByteMinus128(data[96]);
|
||||||
|
if (this->has_state() && this->state == new_state)
|
||||||
|
return;
|
||||||
|
break;
|
||||||
default:
|
default:
|
||||||
return;
|
return;
|
||||||
};
|
};
|
||||||
|
|
|
||||||
|
|
@ -42,6 +42,8 @@ enum NumberIds : uint8_t {
|
||||||
CONF_SET37,
|
CONF_SET37,
|
||||||
CONF_SET38,
|
CONF_SET38,
|
||||||
CONF_SET46,
|
CONF_SET46,
|
||||||
|
CONF_SET47,
|
||||||
|
CONF_SET48,
|
||||||
};
|
};
|
||||||
|
|
||||||
class PanasonicHeatpumpNumber : public number::Number,
|
class PanasonicHeatpumpNumber : public number::Number,
|
||||||
|
|
|
||||||
|
|
@ -392,6 +392,8 @@ text_sensor:
|
||||||
name: "SmartDHW"
|
name: "SmartDHW"
|
||||||
top141:
|
top141:
|
||||||
name: "Quiet Mode Priority"
|
name: "Quiet Mode Priority"
|
||||||
|
top143:
|
||||||
|
name: "DHW Sensor Selection"
|
||||||
|
|
||||||
number:
|
number:
|
||||||
- platform: panasonic_heatpump
|
- platform: panasonic_heatpump
|
||||||
|
|
@ -461,6 +463,12 @@ number:
|
||||||
name: "Set Bivalent AP Start Temp"
|
name: "Set Bivalent AP Start Temp"
|
||||||
set38:
|
set38:
|
||||||
name: "Set Bivalent AP Stop Temp"
|
name: "Set Bivalent AP Stop Temp"
|
||||||
|
set46:
|
||||||
|
name: "Set Heater On Outdoor Temp"
|
||||||
|
set47:
|
||||||
|
name: "Set Heat To Cool Temp"
|
||||||
|
set48:
|
||||||
|
name: "Set Cool To Heat Temp"
|
||||||
|
|
||||||
switch:
|
switch:
|
||||||
- platform: panasonic_heatpump
|
- platform: panasonic_heatpump
|
||||||
|
|
@ -490,6 +498,8 @@ switch:
|
||||||
name: "Set External Heat Cool Control"
|
name: "Set External Heat Cool Control"
|
||||||
set34:
|
set34:
|
||||||
name: "Set Bivalent Control"
|
name: "Set Bivalent Control"
|
||||||
|
error_reset:
|
||||||
|
name: "Error Reset (Restart Heatpump)"
|
||||||
|
|
||||||
select:
|
select:
|
||||||
- platform: panasonic_heatpump
|
- platform: panasonic_heatpump
|
||||||
|
|
@ -516,6 +526,12 @@ select:
|
||||||
name: "Set Quiet Mode Priority"
|
name: "Set Quiet Mode Priority"
|
||||||
set42:
|
set42:
|
||||||
name: "Set Pump Flow Rate Mode"
|
name: "Set Pump Flow Rate Mode"
|
||||||
|
set43:
|
||||||
|
name: "Set DHW Sensor Selection"
|
||||||
|
set44:
|
||||||
|
name: "Set DHW Heater State"
|
||||||
|
set45:
|
||||||
|
name: "Set Room Heater State"
|
||||||
|
|
||||||
climate:
|
climate:
|
||||||
- platform: panasonic_heatpump
|
- platform: panasonic_heatpump
|
||||||
|
|
|
||||||
Loading…