diff --git a/example_panasonic_heatpump.yaml b/example_panasonic_heatpump.yaml index 6ec7f31..1c149df 100644 --- a/example_panasonic_heatpump.yaml +++ b/example_panasonic_heatpump.yaml @@ -68,8 +68,11 @@ external_components: components: [ panasonic_heatpump ] panasonic_heatpump: - uart_hp: uart_heatpump - uart_wm: uart_cz_taw1 + id: my_heatpump + uart_id: uart_heatpump + uart_client_id: uart_cz_taw1 + log_uart_msg: true + update_interval: 3s sensor: - platform: panasonic_heatpump @@ -247,20 +250,22 @@ sensor: name: "Economizer Outlet Temp" top118: name: "Second Room Thermostat Temp" - top119: - name: "Bivalent Heating Start Temperature" - top120: - name: "Bivalent Heating Parallel Adv Starttemp" - top121: - name: "Bivalent Heating Parallel Adv Stoptemp" - top122: - name: "Bivalent Heating Parallel Adv Start Delay" - top123: - name: "Bivalent Heating Parallel Adv Stop Delay" - top125: - name: "2 Zone mixing valve 1 opening" - top126: - name: "2 Zone mixing valve 2 opening" + top127: + name: "Z1 Valve PID" + top128: + name: "Z2 Valve PID" + top131: + name: "Bivalent Start Temperature" + top134: + name: "Bivalent Advanced Start Temp" + top135: + name: "Bivalent Advanced Stop Temp" + top136: + name: "Bivalent Advanced Start Delay" + top137: + name: "Bivalent Advanced Stop Delay" + top138: + name: "Bivalent Advanced DHW Delay" binary_sensor: - platform: panasonic_heatpump @@ -292,6 +297,25 @@ binary_sensor: name: "Anti Freeze Mode" top110: name: "Optional PCB" + top119: + name: "External Control" + top120: + name: "External Heat Cool Control" + top121: + name: "External Error Signal" + top122: + name: "External Compressor Control" + top123: + name: "Z2 Pump State" + top124: + name: "Z1 Pump State" + top129: + name: "Bivalent Control" + top132: + name: "Bivalent Advanced Heat" + top133: + name: "Bivalent Advanced DHW" + text_sensor: - platform: panasonic_heatpump @@ -331,5 +355,124 @@ text_sensor: name: "Z2 Sensor Settings" top114: name: "External Pad Heater" - top124: - name: "Bivalent Heating Setting" + top125: + name: "TwoWay Valve State" + top126: + name: "ThreeWay Valve State2" + top130: + name: "Bivalent Mode" + +number: + - platform: panasonic_heatpump + set5: + name: "Set Z1 Heat Request Temperature" + set6: + name: "Set Z1 Cool Request Temperature" + set7: + name: "Set Z2 Heat Request Temperature" + set8: + name: "Set Z2 Cool Request Temperature" + set11: + name: "Set DHW Temp" + set15: + name: "Set Max Pump Duty" + set16_1: + name: "Set Zone1 Heat Target High" + set16_2: + name: "Set Zone1 Heat Target Low" + set16_3: + name: "Set Zone1 Heat Outside Low" + set16_4: + name: "Set Zone1 Heat Outside High" + set16_5: + name: "Set Zone2 Heat Target High" + set16_6: + name: "Set Zone2 Heat Target Low" + set16_7: + name: "Set Zone2 Heat Outside Low" + set16_8: + name: "Set Zone2 Heat Outside High" + set16_9: + name: "Set Zone1 Cool Target High" + set16_10: + name: "Set Zone1 Cool Target Low" + set16_11: + name: "Set Zone1 Cool Outside Low" + set16_12: + name: "Set Zone1 Cool Outside High" + set16_13: + name: "Set Zone2 Cool Target High" + set16_14: + name: "Set Zone2 Cool Target Low" + set16_15: + name: "Set Zone2 Cool Outside Low" + set16_16: + name: "Set Zone2 Cool Outside High" + set18: + name: "Set Floor Heat Delta" + set19: + name: "Set Floor Cool Delta" + set20: + name: "Set DHW Heat Delta" + set21: + name: "Set Heater Delay Time" + set22: + name: "Set Heater Start Delta" + set23: + name: "Set Heater Stop Delta" + set27: + name: "Set Buffer Delta" + set29: + name: "Set Heating Off Outdoor Temp" + set36: + name: "Set Bivalent Start Temp" + set37: + name: "Set Bivalent AP Start Temp" + set38: + name: "Set Bivalent AP Stop Temp" + +select: + - platform: panasonic_heatpump + set2: + name: "Set Holiday Mode" + set3: + name: "Set Quiet Mode" + set4: + name: "Set Powerful Mode" + set9: + name: "Set Operation Mode" + set17: + name: "Set Zones" + set26: + name: "Set External PadHeater" + set35: + name: "Set Bivalent Mode" + +switch: + - platform: panasonic_heatpump + set1: + name: "Set Heatpump" + set10: + name: "Set Force DHW" + set12: + name: "Set Force Defrost" + set13: + name: "Set Force Sterilization" + set14: + name: "Set Pump" + set24: + name: "Set Main Schedule" + set25: + name: "Set Alt External Sensor" + set28: + name: "Set Buffer" + set30: + name: "Set External Control" + set31: + name: "Set External Error" + set32: + name: "Set External Compressor Control" + set33: + name: "Set External Heat Cool Control" + set34: + name: "Set Bivalent Control"