Added water_heater to README.md

This commit is contained in:
ElVit 2026-02-18 13:22:03 +01:00
parent d8d6b9ed7a
commit 302fb81073
1 changed files with 23 additions and 5 deletions

View File

@ -101,11 +101,19 @@ switch:
climate: climate:
- platform: panasonic_heatpump - platform: panasonic_heatpump
cool_mode: true cool_mode: true
tank: zone1:
name: "DHW" name: "Zone 1"
min_temperature: -5.0 min_temperature: -5.0
max_temperature: 5.0 max_temperature: 5.0
temperature_step: 0.5 temperature_step: 1.0
water_heater:
- platform: panasonic_heatpump
tank:
name: "DHW"
min_temperature: 40.0
max_temperature: 65.0
target_temperature_step: 1.0
``` ```
Thanks to [oxyde42](https://github.com/oxyde42) there is also an exmaple yaml code for the HeishaMon Large Board: Thanks to [oxyde42](https://github.com/oxyde42) there is also an exmaple yaml code for the HeishaMon Large Board:
@ -597,14 +605,24 @@ Here a list of all supported climates:
climate: climate:
- platform: panasonic_heatpump - platform: panasonic_heatpump
cool_mode: false cool_mode: false
tank:
name: "DHW"
zone1: zone1:
name: "Zone 1" name: "Zone 1"
zone2: zone2:
name: "Zone 2" name: "Zone 2"
``` ```
### Water Heater
All water_heater are optional and all options from [water_heater component](https://esphome.io/components/water_heater/) can be applied.
Here a list of all supported water_heater:
```yaml
water_heater:
- platform: panasonic_heatpump
tank:
name: "DHW"
```
## Custom Entities (For Advanced Users) ## Custom Entities (For Advanced Users)
If you review the [ProtocolByteDecrypt.md](https://github.com/Egyras/HeishaMon/blob/master/ProtocolByteDecrypt.md) file you will find also some TOPs and SETs which are not implemented yet in heishamon. If you review the [ProtocolByteDecrypt.md](https://github.com/Egyras/HeishaMon/blob/master/ProtocolByteDecrypt.md) file you will find also some TOPs and SETs which are not implemented yet in heishamon.