From 1b48a1452fe876d6c7acf691f32c3d8026241517 Mon Sep 17 00:00:00 2001 From: ElVit <54866762+ElVit@users.noreply.github.com> Date: Mon, 24 Nov 2025 19:35:21 +0100 Subject: [PATCH] Update test_panasonic_heatpump.yaml --- .../test_panasonic_heatpump.yaml | 126 +++++++++++++----- 1 file changed, 91 insertions(+), 35 deletions(-) diff --git a/tests/panasonic_heatpump/test_panasonic_heatpump.yaml b/tests/panasonic_heatpump/test_panasonic_heatpump.yaml index 1e5ce46..49a9961 100644 --- a/tests/panasonic_heatpump/test_panasonic_heatpump.yaml +++ b/tests/panasonic_heatpump/test_panasonic_heatpump.yaml @@ -140,38 +140,96 @@ binary_sensor: - platform: panasonic_heatpump top0: name: "Test Heatpump State" - top1: - name: "Test Powerful Mode" top2: - name: "Test Quiet Mode" + name: "Test Force DHW State" top3: - name: "Test Holiday Mode" - top4: - name: "Test Force Heater" - top5: - name: "Test Force DHW" - top6: - name: "Test Defrost State" - top7: - name: "Test Fast Hot Start" + name: "Test Quiet Mode Schedule" + top13: + name: "Test Main Schedule State" + top26: + name: "Test Defrosting State" + top60: + name: "Test Internal Heater State" + top61: + name: "Test External Heater State" + top68: + name: "Test Force Heater State" + top69: + name: "Test Sterilization State" + top99: + name: "Test Buffer Installed" + top100: + name: "Test DHW Installed" + top108: + name: "Test Alt External Sensor" + top109: + name: "Test Anti Freeze Mode" + top110: + name: "Test Optional PCB" + top119: + name: "Test External Control" + top120: + name: "Test External Heat Cool Control" + top121: + name: "Test External Error Signal" + top122: + name: "Test External Compressor Control" + top123: + name: "Test Z2 Pump State" + top124: + name: "Test Z1 Pump State" + top129: + name: "Test Bivalent Control" + top132: + name: "Test Bivalent Advanced Heat" + top133: + name: "Test Bivalent Advanced DHW" # Test all text sensors text_sensor: - platform: panasonic_heatpump top4: - name: "Test Operating Mode State" - top13: - name: "Test Last Error" + name: "Test Operation Mode" top17: - name: "Test Main Schedule State" + name: "Test Powerful Mode Time" top18: - name: "Test Main Operating Mode" + name: "Test Quiet Mode Level" top19: - name: "Test Main Zone State" + name: "Test Holiday Mode State" top20: - name: "Test DHW Operating Mode" - top26: - name: "Test Installer Settings" + name: "Test ThreeWay Valve State" + top44: + name: "Test Error" + top58: + name: "Test DHW Heater State" + top59: + name: "Test Room Heater State" + top76: + name: "Test Heating Mode" + top81: + name: "Test Cooling Mode" + top92: + name: "Test Heat Pump Model" + top94: + name: "Test Zones State" + top101: + name: "Test Solar Mode" + top106: + name: "Test Pump Flowrate Mode" + top107: + name: "Test Liquid Type" + top111: + name: "Test Z1 Sensor Settings" + top112: + name: "Test Z2 Sensor Settings" + top114: + name: "Test External Pad Heater" + top125: + name: "Test TwoWay Valve State" + top126: + name: "Test ThreeWay Valve State2" + top130: + name: "Test Bivalent Mode" # Test all number controls number: @@ -196,8 +254,8 @@ number: min_value: -5.0 max_value: 5.0 step: 1.0 - set9: - name: "Test Set DHW Target Temperature" + set11: + name: "Test Set DHW Temp" min_value: 40.0 max_value: 65.0 step: 1.0 @@ -208,19 +266,17 @@ select: set2: name: "Test Set Holiday Mode" set3: - name: "Test Set Powerful Mode" - set4: name: "Test Set Quiet Mode" - set10: - name: "Test Set Z1 Operating Mode" - set11: - name: "Test Set Z2 Operating Mode" - set12: - name: "Test Set DHW Operating Mode" - set13: - name: "Test Set Force Heater" - set14: - name: "Test Set Force DHW" + set4: + name: "Test Set Powerful Mode" + set9: + name: "Test Set Operation Mode" + set17: + name: "Test Set Zones" + set26: + name: "Test Set External PadHeater" + set35: + name: "Test Set Bivalent Mode" # Test all switch controls switch: